1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-766
共 766 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
G3G315-M3G150FF | ebm-papst 380-480V 8000W EC Centrifugal Blower for Boiler Systems
G3G315-M3G150FF | ebm-papst 380-480V 8000W EC Centrifugal Blower for Boiler Systems

Built for boiler systems, G3G315-M3G150FF is a 380-480 V EC centrifugal blower. Among the supplied ratings, 6,000 rpm operation with 6,500 Pa pressure clearly differentiates this variant.

3~ 380-480 315 4600 6500 8000 6000 -
G3G280-BR04-M7 | ebm-papst 400V 530W EC Centrifugal Blower for Servo Motor Cooling
G3G280-BR04-M7 | ebm-papst 400V 530W EC Centrifugal Blower for Servo Motor Cooling

A 400 V EC centrifugal blower for servo motor cooling, G3G280-BR04-M7 has a clearly defined selection profile. Its standout data point is 0-10 V/PWM speed control with a 530 W input rating.

400 280 - - 530 2700 -
G3G250-MW50-01 | ebm-papst 400V 2400W EC Centrifugal Blower for Boiler Systems
G3G250-MW50-01 | ebm-papst 400V 2400W EC Centrifugal Blower for Boiler Systems

Targeting boiler systems, G3G250-MW50-01 pairs 400 V operation with a EC centrifugal blower layout. Its selection profile is led by a listed 92 dB noise value with 2,185 m³/h airflow.

400 250 2185 4600 2400 6100 92
G3G250-GN44-01 | ebm-papst 230V 924W EC Centrifugal Blower for Boiler Systems
G3G250-GN44-01 | ebm-papst 230V 924W EC Centrifugal Blower for Boiler Systems

In boiler systems, G3G250-GN44-01 serves as a 230 V EC centrifugal blower. The model's defining specification is a listed 78 dB noise value with 0-10 V/PWM speed control. It supports exact-model comparison for OEM sourcing.

230 250 1540 2583 924 4480 78
G3G250-GN17-01 | ebm-papst 230V 1117W EC Centrifugal Blower for Boiler Systems
G3G250-GN17-01 | ebm-papst 230V 1117W EC Centrifugal Blower for Boiler Systems

G3G250-GN17-01 is specified as a 230 V EC centrifugal blower for boiler systems. A key model-specific detail is a listed 79 dB noise value with 0-10 V/PWM speed control. It supports exact-model comparison for OEM sourcing.

230 250 1655 2900 1117 5005 79
G3G225-AD29-71 | ebm-papst 230V 545W EC Centrifugal Blower for Pharmaceutical Equipment
G3G225-AD29-71 | ebm-papst 230V 545W EC Centrifugal Blower for Pharmaceutical Equipment

Designed around pharmaceutical equipment, G3G225-AD29-71 uses a 230 V EC centrifugal blower platform. Among the supplied ratings, a listed 58 dB noise value with a 545 W input rating clearly differentiates this variant.

230 225 1655 600 545 1815 58
G3G200-GN18-01 | ebm-papst 230V 682W EC Centrifugal Blower for Boiler Systems
G3G200-GN18-01 | ebm-papst 230V 682W EC Centrifugal Blower for Boiler Systems

For boiler systems, G3G200-GN18-01 provides a 230 V EC centrifugal blower configuration. A listed 63 dB noise value with 5,700 rpm operation is its clearest differentiator in the supplied data.

230 200 1020 2219 682 5700 63
G3G180-AD43-71 | ebm-papst 230V 510W EC Centrifugal Blower for Medical Ventilation
G3G180-AD43-71 | ebm-papst 230V 510W EC Centrifugal Blower for Medical Ventilation

G3G180-AD43-71 combines 230 V operation with a EC centrifugal blower format for medical ventilation. The supplied specifications highlight a listed 56 dB noise value with 0-10 V/PWM speed control.

230 180 1305 700 510 2450 56
G3G160-CU09-11 | ebm-papst 230V 170W EC Centrifugal Blower for Dehumidifiers
G3G160-CU09-11 | ebm-papst 230V 170W EC Centrifugal Blower for Dehumidifiers

Built for dehumidifiers, G3G160-CU09-11 is a 230 V EC centrifugal blower. For selection, its most distinctive listed attribute is 0-10 V/PWM speed control with 650 m³/h airflow.

230 160 650 620 170 2100 -
G2E180-EH03-01 | ebm-papst 230V 400W AC Centrifugal Blower for Air Purification
G2E180-EH03-01 | ebm-papst 230V 400W AC Centrifugal Blower for Air Purification

A 230 V AC centrifugal blower for air purification, G2E180-EH03-01 has a clearly defined selection profile. A key model-specific detail is thermal-overload protection with 755 m³/h airflow.

230 180 755 690 400 1950 -
G2E160-AY47-01 | ebm-papst 230V 240W AC Centrifugal Blower for Cleanroom Ventilation
G2E160-AY47-01 | ebm-papst 230V 240W AC Centrifugal Blower for Cleanroom Ventilation

Targeting cleanroom ventilation, G2E160-AY47-01 pairs 230 V operation with a AC centrifugal blower layout. Among the supplied ratings, thermal-overload protection with a 160 mm frame clearly differentiates this variant.

230 160 590 450 240 2100 -
G2E146-DW07-10 | ebm-papst 230V 150W AC Centrifugal Blower for Wind Turbines
G2E146-DW07-10 | ebm-papst 230V 150W AC Centrifugal Blower for Wind Turbines

In wind turbines, G2E146-DW07-10 serves as a 230 V AC centrifugal blower. IP54 protection with thermal-overload protection is its clearest differentiator in the supplied data.

230 146 380 450 150 1750 -
G2E146-DW07-01 | ebm-papst 230V 140W AC Centrifugal Blower for Wind Turbines
G2E146-DW07-01 | ebm-papst 230V 140W AC Centrifugal Blower for Wind Turbines

G2E146-DW07-01 is specified as a 230 V AC centrifugal blower for wind turbines. The supplied specifications highlight thermal-overload protection with ball-bearing construction.

230 146 475 399 140 1550 -
G2E140-PI51-42 | ebm-papst 230V 225W AC Centrifugal Blower for Inverter Cooling
G2E140-PI51-42 | ebm-papst 230V 225W AC Centrifugal Blower for Inverter Cooling

Designed around inverter cooling, G2E140-PI51-42 uses a 230 V AC centrifugal blower platform. For selection, its most distinctive listed attribute is thermal-overload protection with 460 Pa pressure.

230 140 540 460 225 2100 -
G2E140-PI51-11 | ebm-papst 230V 180W AC Centrifugal Blower for Electric Drives
G2E140-PI51-11 | ebm-papst 230V 180W AC Centrifugal Blower for Electric Drives

For electric drives, G2E140-PI51-11 provides a 230 V AC centrifugal blower configuration. Its standout data point is a 140 mm frame with 2,200 rpm operation. It supports exact-model comparison for OEM sourcing.

230 140 - - 180 2200 -
G2E140-PI51-09 | ebm-papst 230V 225W AC Centrifugal Blower for Electric Drives
G2E140-PI51-09 | ebm-papst 230V 225W AC Centrifugal Blower for Electric Drives

G2E140-PI51-09 combines 230 V operation with a AC centrifugal blower format for electric drives. Its selection profile is led by IP44 protection with thermal-overload protection.

230 140 540 460 225 2100 -
G2E140-PI32-10 | ebm-papst 115V 220W AC Centrifugal Blower for Electric Drives
G2E140-PI32-10 | ebm-papst 115V 220W AC Centrifugal Blower for Electric Drives

Built for electric drives, G2E140-PI32-10 is a 115 V AC centrifugal blower. The model's defining specification is a 140 mm frame with a 220 W input rating. It supports exact-model comparison for OEM sourcing and replacement work.

115 140 470 150 220 1970 -
G2E140-NS38-01 | ebm-papst 230V 105W AC Centrifugal Blower for Emergency Vehicles
G2E140-NS38-01 | ebm-papst 230V 105W AC Centrifugal Blower for Emergency Vehicles

A 230 V AC centrifugal blower for emergency vehicles, G2E140-NS38-01 has a clearly defined selection profile. The supplied specifications highlight thermal-overload protection with a 140 mm frame.

230 140 390 300 105 1800 -
G2E140-AL40-01 | ebm-papst 230V 145W AC Centrifugal Blower for Dehumidifiers
G2E140-AL40-01 | ebm-papst 230V 145W AC Centrifugal Blower for Dehumidifiers

Targeting dehumidifiers, G2E140-AL40-01 pairs 230 V operation with a AC centrifugal blower layout. For selection, its most distinctive listed attribute is IP44 protection with thermal-overload protection.

230 140 340 400 145 1700 -
G2D180-BD18-13 | ebm-papst 400V 430W AC Centrifugal Blower for Inverter Cooling
G2D180-BD18-13 | ebm-papst 400V 430W AC Centrifugal Blower for Inverter Cooling

In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.

400 180 - 840 430 2950 -
显示
681-700
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-766
共 766 个
1 2 ... 30 31 32 33 34 35 36 37 38 39
跳转 页

关于离心风机

适用于紧凑型工业制冷与通风应用的高效离心式气流系统。

如何选择合适的离心风机

在对比离心风机的型号之前,先列明真实的运行需求:所需风量、系统静压、可用安装空间和现场供电条件。忽略这四项因素中任何一项的选型,通常最终都会以退货或现场改造收场。

电压和控制方式决定入围范围。标准选项包括 12/24/48 V DC 和 115/230 V AC;对于工作点会变化的场合,支持 PWM 或 0-10 V 输入的 EC 风机可实现精准调速,测速信号则能提供许多安全系统所需的反馈。

环境条件比任何目录筛选器都更快地淘汰不合适的型号。检查环境温度范围、防尘防潮所需的 IP 防护等级以及预期使用寿命——在立式安装或高温位置,滚珠轴承机型保持噪音和风量指标稳定的时间远长于含油轴承设计。如果设备要销往受监管市场,应在此阶段确认 UL、CE 和 RoHS 认证,并尽早设定以 dBA 为单位的噪音目标,避免声学问题在安装后才暴露。

收尾阶段要为订单排除风险:核实库存水平,确认生产交期,并索取候选型号的规格书和尺寸图,确保安装孔位和接口在采购前核对无误。把您的工作点提供给我们,我们将验证匹配性 该分类现有 766 件产品可随时对比。

离心风机的典型应用场景与案例

从我们的项目记录看,凡是设备需要持续散热、空气需要持续流动的场合都会用到离心风机:数据中心与机房、商用制冷、空调通风系统、通信与电池柜、工业机械设备,以及新能源领域的电力电子设备。这些项目的共同点很朴素——风机成本占比很小,却直接决定设备能否正常运行,值得与被保护设备同等的工程重视。

在最近一个改造项目中,客户的散热机组必须在更换磨损风机的同时保持运行。我们找到了安装尺寸完全相同、风量-压力曲线相当的在产替换型号,并确认了测速输出兼容性,整个安装在一个维护窗口内完成。

第二类高频场景来自制冷维修:冷凝器或蒸发器风机损坏,而原装型号交期漫长。不必等待——我们核对轴承类型、IP 防护等级、叶轮直径和转速,立即提供能恢复制冷量的等效型号。这正是我们的现货库存保护冷链运行的常见方式之一。

无论新造设备还是 ebmpapst 设备的替换项目,在我们这里都遵循同一路径:您提供所需的风量、压力和尺寸,我们回复入围清单、性能曲线和确定的交货日期。

离心风机采购常见问题解答

能否替换我在用的其他供应商的离心风机或已停产的型号?

可以。备件替换供应是我们的核心服务之一:我们会逐一核对您在用机组的安装尺寸、电压、转速和性能曲线,提出最接近的在产系列等效型号。如机壳或接口略有差异,我们会在下单前明确告知差异,确保替换安装不出现意外。

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持离心风机的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。