制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
QFR0624GH | Delta Electronics 24VDC 3.84W Axial Fan for Industrial Automation Cooling

Industrial automation cooling is the intended application for QFR0624GH, a 24VDC axial fan. Its 60 x 60 x 25 mm format is paired with 142 Pa maximum static pressure and a listed 7600 rpm rotor speed.

24 60×60×25 59.1 142 3.84 7600 47
AFB0924VH | Delta Electronics 24VDC 5.28W Axial Fan for Server and Power Supply Cooling

A 25 mm-deep, 92 mm frame makes AFB0924VH a defined fit for server or power-supply ventilation. The 24VDC axial fan is specified at 3800 rpm, with 115 m3/h maximum airflow and 5.28 W listed input.

24 92*92*25 115 - 5.28 3800 45
AFB1212SHE | Delta Electronics 12VDC 12.6W Axial Fan for Server and Power Supply Cooling

AFB1212SHE pairs 12VDC axial fan operation with a listed 142.2 Pa maximum static pressure. For server and power-supply cooling, its 120 x 120 x 38 mm assembly runs at 3700 rpm with a 12.6 W input rating.

12 120x120x38 258.1 142.2 12.6 3700 53
AFB0412SHB | Delta Electronics 12VDC 3W Axial Fan for Server, Storage and Power Supply Cooling

The AFB0412SHB uses a 12VDC axial fan design in a 40 x 40 x 15 mm frame for server and storage cooling. Its 11000 rpm rotor and 3 W listed input define a high-speed option within this compact size class.

12 40*40*15 8.7 16 3 11000 41.5
BFN0724SS-01 | Delta Electronics 24VDC 36W Centrifugal Blower for Electronic Equipment Cooling

A 17300 rpm rating sets BFN0724SS-01 apart within the supplied blower list. This 24VDC centrifugal blower is intended for electronic equipment and ducted local cooling, using a 70 x 70 x 25 mm body.

24 70x70x25 30.4 4897.1 36 17300 38
BFB0512HHA-C | Delta Electronics 12VDC 1.92W Centrifugal Blower for Electronic Equipment Cooling

BFB0512HHA-C is a 12VDC centrifugal blower for local cooling inside electronic equipment. Its directed-airflow format is specified at 5900 rpm, with 196.8 Pa maximum static pressure and 1.92 W input.

12 50*50 6.8 196.8 1.92 5900 37.5
AFB0624LB | Delta Electronics 24VDC 0.96W Axial Fan for Server and Power Supply Cooling

Low listed input is the distinguishing point of AFB0624LB: 0.96 W at 24VDC. This axial fan serves power-supply and server enclosures in a 60 x 60 x 15 mm format, with a 3000 rpm speed rating.

24 60*60*15 19.6 21.7 0.96 3000 24
FFB0412VHN-F00 | Delta Electronics 12VDC 1.92W Axial Fan for Server and Telecom Cooling

For small telecom housings, FFB0412VHN-F00 combines a 40 mm axial footprint with a 28 mm depth. The 12VDC fan is listed at 9500 rpm and 1.92 W, with maximum static pressure specified as 126.8 Pa.

12 40x40x28 26.5 126.8 1.92 9500 45
AFB0524HHB | Delta Electronics 24VDC 1.92W Axial Fan for Server and Power Supply Cooling

AFB0524HHB provides a 50 x 50 x 15 mm axial fan package for power supplies and server electronics. Operating from 24VDC, it lists a 1.92 W input and a maximum static pressure of 78.5 Pa at its rated setup.

24 50*50*15 27.6 78.5 1.92 6400 36
AFB1224VHEVHW | Delta Electronics 24VDC 9.12W Axial Fan for Server and Power Supply Cooling

A 3200 rpm rating gives AFB1224VHEVHW a different operating point from faster 120 mm models. This 24VDC axial fan is intended for server and power-supply cooling, with 9.12 W input and a 38 mm depth.

24 120*120*38 221 - 9.12 3200 48
EFB0405VHD-F00 | Delta Electronics 5VDC 1.6W Axial Fan for Industrial Equipment Cooling

EFB0405VHD-F00 brings 5VDC axial fan cooling to industrial electronics. Within its 40 x 40 x 20 mm envelope, the listed 9000 rpm speed supports a maximum static-pressure rating of 103.7 Pa.

5 40*40*20 17.2 103.7 1.6 9000 32.5
AFB0624SH-A | Delta Electronics 24VDC 4.08W Axial Fan for Server and Power Supply Cooling

Server ventilation with AFB0624SH-A is based on a 24VDC axial fan motor and 60 x 60 x 25 mm frame. A 6000 rpm rating and 4.08 W listed input distinguish this model from the faster EH variants in the list.

24 60*60*25 58.055 - 4.08 6000 44.5
FFB0824EHEYWR | Delta Electronics 24VDC 12W Axial Fan for Server and Telecommunications Cooling

The 80 x 80 x 38 mm FFB0824EHEYWR is a 24VDC axial fan for servers and telecom equipment. Rated at 5700 rpm, it lists 136.34 m3/h maximum airflow; the full suffix identifies the required configuration.

24 80*80*38 136.34 - 12 5700 52.5
AFB0912VH | Delta Electronics 12VDC 4.8W Axial Fan for Server and Power Supply Cooling

AFB0912VH offers a 92 mm axial fan format for server and power-supply cooling on 12VDC. Its listed 4.8 W input accompanies 3800 rpm operation and 115.26 m3/h maximum airflow in a 25 mm-deep body.

12 92*92*25 115.26 - 4.8 3800 45
AFB1224EHEX4A | Delta Electronics 24VDC 20.4W Axial Fan for Server and Power Supply Cooling

For server chassis requiring a 120 mm fan, AFB1224EHEX4A combines 24VDC axial operation with 361.42 m3/h listed maximum airflow. The 38 mm-deep assembly is specified at 4600 rpm and 20.4 W input.

24 120*120*38 361.42 - 20.4 4600 58.5
FFB0412SHN7CA | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling

FFB0412SHN7CA places a 13000 rpm axial fan rotor in a 40 x 40 x 28 mm housing. Intended for server and telecom cooling, this 12VDC model has a listed 6 W input and 40.8 m3/h maximum airflow.

12 40*40*28 40.8 - 6 13000 54.5
EFB0924SHF | Delta Electronics 24VDC Axial Fan for Power Supply and Industrial Equipment Cooling

The EFB0924SHF is a 24VDC axial fan for power supplies and industrial equipment. Its 92 x 92 x 32 mm dimensions provide a distinct intermediate-depth format, with 3500 rpm listed for the rotor.

24 92*92*32 59.5 - - 3500 -
AFB0624EH-A | Delta Electronics 24VDC 5.76W Axial Fan for Server and Power Supply Cooling

A 65.195 m3/h maximum airflow rating separates AFB0624EH-A from lower-output 60 mm options in the supplied list. This 24VDC axial fan supports server and power-supply cooling in a 25 mm-deep housing.

24 60*60*25 65.195 - 5.76 6800 46.5
AFB0624EHW7F | Delta Electronics 24VDC 5.76W Axial Fan for Server and Power Supply Cooling

AFB0624EHW7F targets server and power-supply ventilation with a 24VDC axial fan design. A listed maximum static pressure of 135.5 Pa complements its 60 x 60 x 25 mm frame and 6800 rpm operating speed.

24 60*60*25 65.28 135.5 5.76 6800 46.5
AFB0712VH-A | Delta Electronics 12VDC 5.28W Axial Fan for Server and Power Supply Cooling

Powered by 12VDC, AFB0712VH-A uses a 70 x 70 x 25 mm axial fan layout for server and power-supply cooling. The model is specified at 5500 rpm, with 88.349 m3/h maximum airflow and a 5.28 W input rating.

12 70*70*25 88.349 - 5.28 5500 47.5
显示
141-160
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-178
共 178 个
1 2 3 4 5 6 7 8 9
跳转 页

关于直流风扇

直流风扇涵盖了所有采用直流电动机驱动的风扇类型,包括直流轴流风扇、直流离心风机以及各类微型紧凑型直流风扇。现代直流风扇市场主要由无刷直流(BLDC)技术主导。该技术采用电子换向,取代了机械电刷,与有刷直流方案相比,具有使用寿命更长、效率更高、运行更安静以及电磁干扰更低等优势。直流风扇是服务器和数据中心制冷(采用12V或48V直流供电)、通信设备(使用–48V直流电源)、汽车电子、便携式及电池供电设备,以及太阳能通风系统的首选技术。直流风扇相对于交流风扇的一个重要优势是原生支持PWM调速——这使系统设计人员能够实施智能热管理策略,根据实时温度数据动态调整散热能力。恒瑞备有来自EBM-PAPST、SUNON、三洋电机等全球领先品牌的全系列直流风扇库存,并提供规格选型及替代型号对照的全方位技术支持。

如何选择合适的直流风扇

选择合适的直流风扇,应从工作点出发而不是从型号名称出发。先确定您实际需要的风量(CFM 或 m³/h)以及风机需要克服的静压,再寻找性能曲线能以一定裕量穿过该工作点的机型,而不是刚好压在曲线边缘的产品。

电气细节要尽早确认。DC 风机通常采用 12/24/48 V 供电,易于与控制板集成;AC 风机适合 115/230 V 定速安装场合。如果风量需要随负载变化,请选择支持 PWM 或模拟量控制的 EC 技术;在需要状态监控的场合,测速输出可以让控制器及时发现风机故障。

下一步是环境与认证。根据粉尘和潮湿暴露程度匹配 IP 防护等级,凡在高温、立式或全天候连续运行的场合,优先选择滚珠轴承,并对照目标市场确认 UL、CE、RoHS 等认证。尽早以 dBA 设定声学限值,可以避免第一台样机噪声过大时的后期返工。

最后,请从整体供货风险而非单纯价格来比较候选型号:确认所需数量的现货情况,核实后续批次的交期,并在确认前索取规格书和尺寸图。报价前,我们的团队会为您交叉核对曲线、尺寸和电气参数 该分类目前有 178 件产品可供对比。

直流风扇的典型应用场景与案例

直流风扇几乎出现在所有需要可靠排热或换气的行业。典型环境包括机房与数据中心、制冷冷凝器与冷库蒸发器、暖通空调组合式空调机组、通信机柜、医疗与实验室设备、焊接与数控机床机壳,以及新能源电力柜。在这些场景中,风机都是关键部件:一旦故障就意味着停产、货物受损或代价高昂的紧急停机。

一个反复出现的场景来自控制柜改造:原装风机已停产,安装孔位不能改动,停机时间以小时计。我们按机壳尺寸、风量和噪音将旧型号与在产系列逐一比对,提出最接近的直接替换方案,并随货附上规格书,让电工无需重新设计即可接线。

对冷库运营方来说,痛点很直接:蒸发器或冷凝器风机故障必须立即更换,而不是等六周的进口周期。将叶轮直径、转速和防护等级与现货等效型号逐一比对,我们能在几天内恢复制冷能力——备件替换供应也因此成为我们在该分类下的核心业务。

无论项目是全新设备还是在用 Delta 机组的替换,流程都一样:把工作点和约束条件发给我们,我们回报经过验证的选型结果,并附规格书、性能曲线和明确的交期。

直流风扇采购常见问题解答

是否支持直流风扇的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

采购前能提供哪些技术资料?

下单前可按需提供规格书、性能曲线、尺寸图和认证文件(视适用情况提供 UL、CE、RoHS)——我们始终认为,采购订单应建立在经过验证的选型之上,而不是取代选型。对于项目投标,我们还可以提供产品对比表,把候选型号按您关注的参数逐项并列呈现。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。