| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EF92252B1-000U-G99 | SUNON 24V 1.52W 92x92x25mm 87.5m3/h DC Axial Fan for Industrial Cooling The EF92252B1-000U-G99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Review its selection parameters during airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 92x92x25mm | 87.5 | 42.3 | 1.52 | 3000 | 34 | |
![]() EF92252BX-1000U-G99 | SUNON 24V 2.16W 92x92x25mm 93.4m3/h DC Axial Fan for Industrial Cooling For telecom cabinets, base stations, and network equipment, EF92252BX-1000U-G99 combines 24 VDC operation with a 92 × 92 × 25 mm DC axial fan design. Up to 93.4 m³/h is its most prominent listed performance figure. Treat the rated dataset as a primary input to airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 92x92x25mm | 93.4 | 52.3 | 2.16 | 3400 | 36.9 | |
![]() PF92252V1-1000U-G99 | SUNON 24V 5.04W 92x92x25mm 4500rpm DC Axial Fan for Industrial Cooling SUNON PF92252V1-1000U-G99 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 5.04 W input is the defining electrical load in the supplied data. Base airflow-path design on the stated motor input. Obtain the applicable curve before final duty-point approval. |
24 | 92x92x25mm | - | 87.2 | 5.04 | 4500 | - | |
![]() PF80252B1-1000U-G99 | SUNON 24V 3.72W 80x80x25mm 4800rpm DC Axial Fan for Industrial Cooling Used in servers and data-center electronics, SUNON PF80252B1-1000U-G99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. 102.1 Pa maximum pressure is the standout documented duty-point value. During airflow-path design, compare the model's ventilation capacity. Obtain the applicable curve before final duty-point approval. |
24 | 80x80x25mm | - | 102.1 | 3.72 | 4800 | - | |
![]() MF80151V1-1000U-G99 | SUNON 12V 1.5W 80x80x15mm 3500rpm DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF80151V1-1000U-G99 serves as a 80 × 80 × 15 mm DC axial fan operating at 12 VDC. Its 3500 rpm rating defines a lower-speed operating point. The recorded equipment fit should guide airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 80x80x15mm | - | 42.3 | 1.5 | 3500 | - | |
![]() ME80152V1-000U-G99 | SUNON 24V 2.21W 80x80x15mm 62.9m3/h DC Axial Fan for Industrial Cooling Built for industrial electronics and equipment cooling, SUNON ME80152V1-000U-G99 uses a 80 × 80 × 15 mm DC blower arrangement at 24 VDC. Its 3000 rpm rating defines a lower-speed operating point. For airflow-path design, start with the supplied suffix definition. Obtain the applicable curve before final duty-point approval. |
24 | 80x80x15mm | 62.9 | 34.9 | 2.21 | 3000 | 34.7 | |
![]() ME70151V3-000U-A99 | SUNON 12V 0.57W 70x70x15mm 32.3m3/h DC Axial Fan for Industrial Cooling The ME70151V3-000U-A99 is SUNON's 12 VDC, 70 × 70 × 15 mm DC blower option for industrial electronics and equipment cooling. Its 2300 rpm rating defines a lower-speed operating point. Use the documented catalog specification when planning airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 70x70x15mm | 32.3 | 17.4 | 0.57 | 2300 | 21.5 | |
![]() PMD2407PTB3-A.F | SUNON 24V 2.9W 70x70x25mm 68m3/h 4200rpm DC Axial Fan for Industrial Cooling For compact cooling within industrial electronics and equipment cooling, the PMD2407PTB3-A.F provides a 24 VDC DC blower configuration measuring 70 × 70 × 25 mm. Its 4200 rpm rating defines a lower-speed operating point. Review its thermal-duty record during airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 70x70x25mm | 68 | 62.3 | 2.9 | 4200 | 39 | |
![]() MF60202V1-1000U-G99 | SUNON 24V 1.32W 60x60x20mm 5000rpm DC Axial Fan for Telecommunications SUNON MF60202V1-1000U-G99 combines a 60 × 60 × 20 mm DC axial fan platform with a 24 VDC rating for telecom cabinets and network equipment. A listed input of 1.32 W is the model's notable electrical characteristic. Treat the performance curve as a primary input to airflow-path design. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x20mm | - | 52.3 | 1.32 | 5000 | - | |
![]() MF60252V1-1000U-G99 | SUNON 24V 1.2W 60x60x25mm 4500rpm DC Axial Fan for Telecommunications Applied in telecom cabinets and network equipment, SUNON MF60252V1-1000U-G99 is a 24 VDC DC axial fan in a 60 × 60 × 25 mm frame. A listed input of 1.2 W is the model's notable electrical characteristic. Base airflow-path design on the stated mounting size. Obtain the applicable curve before final duty-point approval. |
24 | 60x60x25mm | - | 52.3 | 1.2 | 4500 | - | |
![]() EE50101S1-1000U-C99 | SUNON 12V 1.08W 50x50x10mm 22.1m3/h DC Axial Fan for Industrial Cooling Within telecom cabinets, base stations, and network equipment, SUNON EE50101S1-1000U-C99 serves as a 50 × 50 × 10 mm DC blower operating at 12 VDC. Its 22.1 m³/h airflow rating suits the stated equipment-cooling role. During airflow-path design, compare the model's supply requirement. Obtain the applicable curve before final duty-point approval. |
12 | 50x50x10mm | 22.1 | 34.9 | 1.08 | 5700 | 30.7 | |
![]() EF40201BX-1000U-G99 | SUNON 12V 0.78W 40x40x20mm 8200rpm DC Axial Fan for Industrial Cooling EF40201BX-1000U-G99 serves telecom cabinets, base stations, and network equipment as a 40 × 40 × 20 mm DC axial fan rated at 12 VDC. 8200 rpm is the model's most distinctive operating parameter. The recorded static-pressure entry should guide airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 40x40x20mm | - | 79.7 | 0.78 | 8200 | - | |
![]() EEC0251B2-000U-G99 | SUNON 12V 3.4W 120x120x25mm 2700rpm DC Axial Fan for Industrial Cooling The EEC0251B2-000U-G99 is SUNON's 12 VDC, 120 × 120 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 2700 rpm rating defines a lower-speed operating point. For airflow-path design, start with the supplied volume-flow figure. Obtain the applicable curve before final duty-point approval. |
12 | 120x120x25mm | - | 54.8 | 3.4 | 2700 | - | |
![]() MF60251VX-1000U-G99 | SUNON 12V 1.56W 60x60x25mm 45.9m3/h DC Axial Fan for Telecommunications SUNON MF60251VX-1000U-G99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets and network equipment. A listed noise value of 31.2 dB is the model's key differentiator. Review its rotational rating during airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 60*60*25 | 45.9 | - | 1.56 | 5200 | 31.2 | |
![]() MF40060V1-1000U-S99 | SUNON 5V 0.44W 40x40x6mm 10.71m3/h DC Axial Fan for Telecommunications Positioned for telecom cabinets and network equipment, SUNON MF40060V1-1000U-S99 is a 5 VDC DC axial fan in a 40 × 40 × 6 mm frame. A listed input of 0.44 W is the model's notable electrical characteristic. Treat the power demand as a primary input to airflow-path design. Obtain the applicable curve before final duty-point approval. |
5 | 40*40*6 | 10.71 | - | 0.44 | 7000 | 29.3 | |
![]() GM1202PFV2-8 F.GN | SUNON 12V 3W 25x25x10mm 5.1m3/h 10000rpm DC Axial Fan for Industrial Cooling GM1202PFV2-8 F.GN addresses industrial electronics and equipment cooling through a 12 VDC DC blower platform measuring 25 × 25 × 10 mm. Its 5.1 m³/h airflow rating suits the stated equipment-cooling role. During airflow-path design, compare the model's cooling output. Obtain the applicable curve before final duty-point approval. |
12 | 25*25*10 | 5.1 | - | 3 | 10000 | 16 | |
![]() ME80251V3-000U-F99 | SUNON 12V 1.1W 80x80x25mm DC Axial Fan for Industrial Cooling The ME80251V3-000U-F99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC blower option for industrial electronics and equipment cooling. A listed input of 1.1 W is the model's notable electrical characteristic. The recorded operating point should guide airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*25 | - | - | 1.1 | - | - | |
![]() MF35060V2-1000U-G99 | SUNON 5V 0.35W 35x35x6mm 7.31m3/h DC Axial Fan for Telecommunications SUNON configures MF35060V2-1000U-G99 as a 35 × 35 × 6 mm DC axial fan for telecom cabinets and network equipment, operating at 5 VDC. A listed input of 0.35 W is the model's notable electrical characteristic. For airflow-path design, start with the supplied pressure capability. Obtain the applicable curve before final duty-point approval. |
5 | 35*35*6 | 7.31 | - | 0.35 | 5800 | 18.3 | |
![]() VF80381BX-Q394-S9H | SUNON 12V 57.96W 80x80x38mm DC Axial Fan for Data Center Cooling SUNON VF80381BX-Q394-S9H combines a 80 × 80 × 38 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. 57.96 W input is the defining electrical load in the supplied data. Use the documented dimensional envelope when planning airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*38 | - | - | 57.96 | - | - | |
![]() PF80251B3-1000U-S99 | SUNON 12V 2.34W 80x80x25mm 90.1m3/h DC Axial Fan for Industrial Cooling Built around servers and data-center electronics, SUNON PF80251B3-1000U-S99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 90.1 m³/h is its most prominent listed performance figure. Review its acoustic value during airflow-path design. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*25 | 90.1 | - | 2.34 | 4200 | 42.5 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。