| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() MF20080V1-1000U-A99 | SUNON 5V 0.72W 20x20x8mm 1.6m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF20080V1-1000U-A99 serves as a 20 × 20 × 8 mm DC axial fan operating at 5 VDC. Its 1.6 m³/h airflow rating suits the stated equipment-cooling role. Review its electrical load during replacement evaluation. Check the full suffix before confirming connector details. |
5 | 20*20*8 | 1.6 | - | 0.72 | 15000 | 23 | |
![]() MF60252VX-1000U-A99 | SUNON 24V 2.04W 60x60x25mm 27m3/h 5200rpm DC Axial Fan for New Energy SUNON MF60252VX-1000U-A99 is a 24 VDC DC axial fan for inverters, energy-storage systems, and charging equipment. Its 27 m³/h airflow rating suits the stated equipment-cooling role. Treat the speed benchmark as a primary input to replacement evaluation. Check the full suffix before confirming connector details. |
24 | 60*60*25 | 27 | - | 2.04 | 5200 | 31.2 | |
![]() MF50152V1-1000U-G99 | SUNON 24V 1.08W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications For thermal management in telecom cabinets and network equipment, the MF50152V1-1000U-G99 provides a 24 VDC DC axial fan configuration measuring 50 × 50 × 15 mm. Its 17 m³/h airflow rating suits the stated equipment-cooling role. During enclosure sizing, compare the model's application data. Verify bearing and signal options in the exact datasheet. |
24 | 50*50*15 | 17 | - | 1.08 | 6100 | 33 | |
![]() PMD2412PTB1-A (2).GN | SUNON 24V 11.8W 120x120x38mm DC Axial Fan for Industrial Cooling SUNON PMD2412PTB1-A (2).GN combines a 120 × 120 × 38 mm DC axial fan platform with a 24 VDC rating for industrial electronics and equipment cooling. 11.8 W input is the defining electrical load in the supplied data. The recorded technical profile should guide enclosure sizing. Verify bearing and signal options in the exact datasheet. |
24 | 120*120*38 | - | - | 11.8 | - | - | |
![]() MF60152VX-1000U-A99 | SUNON 24V 2.04W 60x60x15mm 30.4m3/h DC Axial Fan for Telecommunications Positioned for telecom cabinets and network equipment, SUNON MF60152VX-1000U-A99 is a 24 VDC DC axial fan in a 60 × 60 × 15 mm frame. Its 30.4 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied model record. Verify bearing and signal options in the exact datasheet. |
24 | 60*60*15 | 30.4 | - | 2.04 | 5400 | 36.2 | |
![]() PMD2409PMB1-A (2).GN | SUNON 24V 12.2W 92x92x38mm 120.2m3/h DC Axial Fan for Industrial Cooling Within industrial electronics and equipment cooling, SUNON PMD2409PMB1-A (2).GN serves as a 92 × 92 × 38 mm DC axial fan operating at 24 VDC. The supplied data list 57.6 dB, an important acoustic selection parameter. Use the documented product configuration when planning enclosure sizing. Verify bearing and signal options in the exact datasheet. |
24 | 92*92*38 | 120.2 | - | 12.2 | 4900 | 57.6 | |
![]() PMD2408PMB1-A(2).F.GN | SUNON 24V 9.6W 80x80x38mm 84.1m3/h DC Axial Fan for Industrial Cooling A 80 × 80 × 38 mm frame and 24 VDC rating define PMD2408PMB1-A(2).F.GN, a DC blower for industrial electronics and equipment cooling. The supplied data list 55.2 dB, an important acoustic selection parameter. Review its system interface during enclosure sizing. Verify bearing and signal options in the exact datasheet. |
24 | 80*80*38 | 84.1 | - | 9.6 | 5700 | 55.2 | |
![]() PMD2408PMB1-A (2).GN | SUNON 24V 9.6W 80x80x38mm 84m3/h DC Axial Fan for Industrial Cooling Within industrial electronics and equipment cooling, PMD2408PMB1-A (2).GN provides a 80 × 80 × 38 mm, 24 VDC DC blower configuration. The supplied data list 55.2 dB, an important acoustic selection parameter. Base enclosure sizing on the stated duty-point values. Verify bearing and signal options in the exact datasheet. |
24 | 80*80*38 | 84 | - | 9.6 | 5700 | 55.2 | |
![]() MF50151V1-1000U-G99 | SUNON 12V 0.92W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications SUNON MF50151V1-1000U-G99 combines a 50 × 50 × 15 mm DC blower platform with a 12 VDC rating for telecom cabinets and network equipment. Its 17 m³/h airflow rating suits the stated equipment-cooling role. During enclosure sizing, compare the model's installation footprint. Verify bearing and signal options in the exact datasheet. |
12 | 50*50*15 | 17 | - | 0.92 | 6100 | 33 | |
![]() MF40201VX-1000U-G99 | SUNON 12V 0.96W 40x40x20mm 18.3m3/h DC Axial Fan for Telecommunications Built around telecom cabinets and network equipment, SUNON MF40201VX-1000U-G99 is a 12 VDC DC axial fan in a 40 × 40 × 20 mm frame. 8000 rpm is the model's most distinctive operating parameter. The recorded selection parameters should guide enclosure sizing. Verify bearing and signal options in the exact datasheet. |
12 | 40x40x20 | 18.3 | 72.2 | 0.96 | 8000 | 27.5 | |
![]() MF25100V1-1000U-A99 | SUNON 5V 0.58W 25x25x10mm 3.5m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF25100V1-1000U-A99 serves as a 25 × 25 × 10 mm DC axial fan operating at 5 VDC. Its 3.5 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied rated dataset. Verify bearing and signal options in the exact datasheet. |
5 | 25*25*10 | 3.5 | - | 0.58 | 13000 | 23 | |
![]() EEC0382B2-000U-A99 | SUNON 24V 5.4W 120x120x38mm 116m3/h DC Axial Fan for Industrial Cooling SUNON EEC0382B2-000U-A99 is a 24 VDC DC blower in a 120 × 120 × 38 mm format for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. Use the documented motor input when planning enclosure sizing. Verify bearing and signal options in the exact datasheet. |
24 | 120*120*38 | 116 | - | 5.4 | 2600 | 44 | |
![]() PF92252B1-1000U-A99 | SUNON 24V 4.92W 92x92x25mm 127.5m3/h DC Axial Fan for Industrial Cooling For ventilation needs in servers and data-center electronics, the PF92252B1-1000U-A99 provides a 24 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Up to 127.5 m³/h is its most prominent listed performance figure. Treat the equipment fit as a primary input to enclosure sizing. Verify bearing and signal options in the exact datasheet. |
24 | 92*92*25 | 127.5 | - | 4.92 | 4500 | 46.1 | |
![]() MF40100V1-1000U-A99 | SUNON 5V 0.83W 40x40x10mm 8m3/h DC Axial Fan for Telecommunications SUNON MF40100V1-1000U-A99 combines a 40 × 40 × 10 mm DC axial fan platform with a 5 VDC rating for telecom cabinets and network equipment. Its 8 m³/h airflow rating suits the stated equipment-cooling role. Base enclosure sizing on the stated suffix definition. Verify bearing and signal options in the exact datasheet. |
5 | 40*40*10 | 8 | - | 0.83 | 7000 | 27.3 | |
![]() ME80152V1-000U-A99 | SUNON 24V 2.21W 80x80x15mm 37m3/h DC Axial Fan for Industrial Cooling Configured for industrial electronics and equipment cooling, SUNON ME80152V1-000U-A99 is a 24 VDC DC blower in a 80 × 80 × 15 mm frame. Its 3000 rpm rating defines a lower-speed operating point. During enclosure sizing, compare the model's catalog specification. Verify bearing and signal options in the exact datasheet. |
24 | 80*80*15 | 37 | - | 2.21 | 3000 | 34.7 | |
![]() MF60251V1-1000U-A99 | SUNON 12V 0.96W 60x60x25mm 23.5m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF60251V1-1000U-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. A listed noise value of 27 dB is the model's key differentiator. The recorded thermal-duty record should guide enclosure sizing. Verify bearing and signal options in the exact datasheet. |
12 | 60*60*25 | 23.5 | - | 0.96 | 4500 | 27 | |
![]() MF30101V1-1000U-A99 | SUNON 12V 0.83W 30x30x10mm 5.5m3/h 11500rpm DC Axial Fan for New Energy SUNON configures MF30101V1-1000U-A99 as a 30 × 30 × 10 mm DC axial fan for inverters, energy-storage systems, and charging equipment, operating at 12 VDC. Its 5.5 m³/h airflow rating suits the stated equipment-cooling role. For enclosure sizing, start with the supplied performance curve. Verify bearing and signal options in the exact datasheet. |
12 | 30*30*10 | 5.5 | - | 0.83 | 11500 | 23 | |
![]() MF50151V1-1000U-A99 | SUNON 12V 0.92W 50x50x15mm 17m3/h DC Axial Fan for Telecommunications The MF50151V1-1000U-A99 is SUNON's 12 VDC, 50 × 50 × 15 mm DC blower option for telecom cabinets and network equipment. Its 17 m³/h airflow rating suits the stated equipment-cooling role. Use the documented mounting size when planning enclosure sizing. Verify bearing and signal options in the exact datasheet. |
12 | 50*50*15 | 17 | - | 0.92 | 6100 | 33 | |
![]() MF60152V1-1000U-A99 | SUNON 24V 2.02W 60x60x15mm 26.4m3/h DC Axial Fan for Telecommunications For compact cooling within telecom cabinets and network equipment, the MF60152V1-1000U-A99 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 15 mm. Its 26.4 m³/h airflow rating suits the stated equipment-cooling role. Review its supply requirement during enclosure sizing. Verify bearing and signal options in the exact datasheet. |
24 | 60*60*15 | 26.4 | - | 2.02 | 4700 | 34.2 | |
![]() HA60151V4-1000U-A99 | SUNON 12V 0.36W 60x60x15mm 12.7m3/h DC Axial Fan for Industrial Cooling HA60151V4-1000U-A99 serves telecom cabinets, base stations, and network equipment as a 60 × 60 × 15 mm DC axial fan rated at 12 VDC. A listed noise value of 14.5 dB is the model's key differentiator. Treat the static-pressure entry as a primary input to enclosure sizing. Verify bearing and signal options in the exact datasheet. |
12 | 60*60*15 | 12.7 | - | 0.36 | 2200 | 14.5 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。