| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EE92251B1-000U-G99 | SUNON 12V 2W 92x92x25mm 87.5m3/h DC Axial Fan for Industrial Cooling The EE92251B1-000U-G99 is SUNON's 12 VDC, 92 × 92 × 25 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. The recorded airflow profile should guide thermal validation. Review connector, alarm, and sensor options separately. |
12 | 92x92x25mm | 87.5 | 37.4 | 2 | 3000 | 34 | |
![]() EE80252B1-000U-A99 | SUNON 24V 1.8W 80x80x25mm 69.7m3/h DC Axial Fan for Industrial Cooling SUNON EE80252B1-000U-A99 combines a 80 × 80 × 25 mm DC blower platform with a 24 VDC rating for telecom cabinets, base stations, and network equipment. Its 3200 rpm rating defines a lower-speed operating point. Use the documented technical profile when planning wiring review. Confirm environmental protection for the ordered version. |
24 | 80x80x25mm | 69.7 | 44.8 | 1.8 | 3200 | 33 | |
![]() GF92251B1-000U-GE9 | SUNON 12V 92x92x25mm DC Axial Fan for Industrial Cooling The GF92251B1-000U-GE9 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Its 92 × 92 × 25 mm format is the main stated selection detail. During wiring review, compare the model's cooling specification. Confirm environmental protection for the ordered version. |
12 | 92x92x25mm | - | - | - | - | - | |
![]() EE80252BX-000U-A99 | SUNON 24V 1.9W 80x80x25mm 76.5m3/h DC Axial Fan for Industrial Cooling For airflow duties across telecom cabinets, base stations, and network equipment, the EE80252BX-000U-A99 provides a 24 VDC DC blower configuration measuring 80 × 80 × 25 mm. Its 3600 rpm rating defines a lower-speed operating point. The recorded duty-point values should guide wiring review. Confirm environmental protection for the ordered version. |
24 | 80x80x25mm | 76.5 | 57.3 | 1.9 | 3600 | 38 | |
![]() EEC0251B1-000U-A99 | SUNON 12V 5.4W 120x120x25mm 183.8m3/h DC Axial Fan for Industrial Cooling Designed for telecom cabinets, base stations, and network equipment, SUNON EEC0251B1-000U-A99 is a 12 VDC DC axial fan in a 120 × 120 × 25 mm frame. Up to 183.8 m³/h is its most prominent listed performance figure. Use the documented selection parameters when planning wiring review. Confirm environmental protection for the ordered version. |
12 | 120x120x25 | 183.8 | 69.7 | 5.4 | 3100 | 44.5 | |
![]() PE60251B1-000U-G99 | SUNON 12V 3.57W 60x60x25mm 61.2m3/h DC Axial Fan for Industrial Cooling SUNON PE60251B1-000U-G99 is a 12 VDC DC blower in a 60 × 60 × 25 mm format for industrial electronics and equipment cooling. 134.5 Pa maximum pressure is the standout documented duty-point value. Treat the motor input as a primary input to wiring review. Confirm environmental protection for the ordered version. |
12 | 60x60x25mm | 61.2 | 134.5 | 3.57 | 6900 | 44 | |
![]() EF60252S1-1000U-A99 | SUNON 24V 1.2W 60x60x25mm 39.9m3/h DC Axial Fan for Industrial Cooling The EF60252S1-1000U-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. A listed noise value of 27 dB is the model's key differentiator. Base wiring review on the stated ventilation capacity. Confirm environmental protection for the ordered version. |
24 | 60x60x25 | 39.9 | 52.3 | 1.2 | 4500 | 27 | |
![]() PF97332B2-L03C-S99 | SUNON 24V 9.12W 97x33mm DC Axial Fan for Industrial Cooling For ventilation needs in servers and data-center electronics, the PF97332B2-L03C-S99 provides a 24 VDC DC blower configuration measuring 97 × 33 mm. 9.12 W input is the defining electrical load in the supplied data. During wiring review, compare the model's equipment fit. Confirm environmental protection for the ordered version. |
24 | 97*33 | - | - | 9.12 | - | - | |
![]() PF70201V1-000U-A99 | SUNON 12V 3.42W 70x70x20mm 73.1m3/h DC Axial Fan for Industrial Cooling Used in servers and data-center electronics, SUNON PF70201V1-000U-A99 is a 12 VDC DC blower in a 70 × 70 × 20 mm frame. Up to 73.1 m³/h is its most prominent listed performance figure. For wiring review, start with the supplied catalog specification. Confirm environmental protection for the ordered version. |
12 | 70x70x20mm | 73.1 | 69.7 | 3.42 | 4600 | 41.5 | |
![]() PF80251B1-000U-G99 | SUNON 12V 4.1W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON PF80251B1-000U-G99, a DC axial fan rated at 12 VDC and sized 80 × 80 × 25 mm. 102.1 Pa maximum pressure is the standout documented duty-point value. Review its performance curve during wiring review. Confirm environmental protection for the ordered version. |
12 | 80x80x25mm | 101.9 | 102.1 | 4.1 | 4800 | 47.5 | |
![]() PF92251B1-000U-G99 | SUNON 12V 4.7W 92x92x25mm 127.4m3/h DC Axial Fan for Industrial Cooling The PF92251B1-000U-G99 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Up to 127.4 m³/h is its most prominent listed performance figure. Treat the mounting size as a primary input to wiring review. Confirm environmental protection for the ordered version. |
12 | 92x92x25mm | 127.4 | 87.2 | 4.7 | 4500 | 47 | |
![]() EEC0381B1-000U-G99 | SUNON 12V 10W 120x120x38mm 234.09m3/h DC Axial Fan for Industrial Cooling The 12 VDC SUNON EEC0381B1-000U-G99 is a DC blower sized 120 × 120 × 38 mm for telecom cabinets, base stations, and network equipment. Up to 234.09 m³/h is its most prominent listed performance figure. Base wiring review on the stated supply requirement. Confirm environmental protection for the ordered version. |
12 | 120x120x38mm | 234.09 | 89.6 | 10 | 3100 | 48 | |
![]() PF80252B2-1D03U-S99 | SUNON 24V 3.24W 80x80x25mm 96.8m3/h DC Axial Fan for Industrial Cooling Applied in servers and data-center electronics, SUNON PF80252B2-1D03U-S99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 96.8 m³/h is its most prominent listed performance figure. The recorded volume-flow figure should guide wiring review. Confirm environmental protection for the ordered version. |
24 | 80x80x25mm | 96.8 | 87.2 | 3.24 | 4500 | 44 | |
![]() EE60252B1-000U-A99 | SUNON 24V 1.68W 60x60x25mm 39.9m3/h DC Axial Fan for Industrial Cooling Within telecom cabinets, base stations, and network equipment, SUNON EE60252B1-000U-A99 serves as a 60 × 60 × 25 mm DC blower operating at 24 VDC. Its 39.9 m³/h airflow rating suits the stated equipment-cooling role. For wiring review, start with the supplied sound level. Confirm environmental protection for the ordered version. |
24 | 60x60x25mm | 39.9 | 52.3 | 1.68 | 4500 | 34.5 | |
![]() HA92251V4-1000U-A99 | SUNON 12V 0.54W 92x92x25mm 47.7m3/h DC Axial Fan for Industrial Cooling Specified at 12 VDC, HA92251V4-1000U-A99 is a SUNON DC axial fan for telecom cabinets, base stations, and network equipment in 92 × 92 × 25 mm dimensions. Its 1700 rpm rating defines a lower-speed operating point. Use the documented rotational rating when planning wiring review. Confirm environmental protection for the ordered version. |
12 | 92x92x25 | 47.7 | 12.4 | 0.54 | 1700 | 17.7 | |
![]() EF80152B1-EE070-S99 | SUNON 24V 2.16W 80x80x15mm DC Axial Fan for Industrial Cooling Built for telecom cabinets, base stations, and network equipment, SUNON EF80152B1-EE070-S99 uses a 80 × 80 × 15 mm DC blower arrangement at 24 VDC. 2.16 W input is the defining electrical load in the supplied data. Treat the frame geometry as a primary input to wiring review. Confirm environmental protection for the ordered version. |
24 | 80*80*15 | - | - | 2.16 | - | - | |
![]() PE92252B1-000U-G99 | SUNON 24V 5.28W 92x92x25mm 127.4m3/h DC Axial Fan for Industrial Cooling Positioned for industrial electronics and equipment cooling, SUNON PE92252B1-000U-G99 is a 24 VDC DC blower in a 92 × 92 × 25 mm frame. Up to 127.4 m³/h is its most prominent listed performance figure. During wiring review, compare the model's operating point. Confirm environmental protection for the ordered version. |
24 | 92x92x25mm | 127.4 | 87.2 | 5.28 | 4500 | 47 | |
![]() EE92251BX-000U-A99 | SUNON 12V 2.3W 92x92x25mm 93.4m3/h DC Axial Fan for Industrial Cooling Within telecom cabinets, base stations, and network equipment, SUNON EE92251BX-000U-A99 serves as a 92 × 92 × 25 mm DC blower operating at 12 VDC. Up to 93.4 m³/h is its most prominent listed performance figure. The recorded pressure capability should guide wiring review. Confirm environmental protection for the ordered version. |
12 | 92x92x25mm | 93.4 | 52.3 | 2.3 | 3400 | 37.5 | |
![]() EF50151BX-1L02C-S99 | SUNON 12V 1.8W 50x50x15mm DC Centrifugal Blower for Industrial Cooling Within telecom cabinets, base stations, and network equipment, EF50151BX-1L02C-S99 provides a 50 × 50 × 15 mm, 12 VDC DC blower configuration. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. For wiring review, start with the supplied dimensional envelope. Confirm environmental protection for the ordered version. |
12 | 50x50x15mm | 9.2 | 241.6 | 1.8 | 6200 | 45.8 | |
![]() EE92252B1-000U-G99 | SUNON 24V 2.1W 92x92x25mm 87.5m3/h DC Axial Fan for Industrial Cooling The EE92252B1-000U-G99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC blower option for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Use the documented acoustic value when planning wiring review. Confirm environmental protection for the ordered version. |
24 | 92x92x25mm | 87.5 | 37.4 | 2.1 | 3000 | 34 |
选择合适的工业冷却,应从工作点出发而不是从型号名称出发。先确定您实际需要的风量(CFM 或 m³/h)以及风机需要克服的静压,再寻找性能曲线能以一定裕量穿过该工作点的机型,而不是刚好压在曲线边缘的产品。
电气细节要尽早确认。DC 风机通常采用 12/24/48 V 供电,易于与控制板集成;AC 风机适合 115/230 V 定速安装场合。如果风量需要随负载变化,请选择支持 PWM 或模拟量控制的 EC 技术;在需要状态监控的场合,测速输出可以让控制器及时发现风机故障。
下一步是环境与认证。根据粉尘和潮湿暴露程度匹配 IP 防护等级,凡在高温、立式或全天候连续运行的场合,优先选择滚珠轴承,并对照目标市场确认 UL、CE、RoHS 等认证。尽早以 dBA 设定声学限值,可以避免第一台样机噪声过大时的后期返工。
最后,请从整体供货风险而非单纯价格来比较候选型号:确认所需数量的现货情况,核实后续批次的交期,并在确认前索取规格书和尺寸图。报价前,我们的团队会为您交叉核对曲线、尺寸和电气参数 该分类目前有 642 件产品可供对比。
工业冷却几乎出现在所有需要可靠排热或换气的行业。典型环境包括机房与数据中心、制冷冷凝器与冷库蒸发器、暖通空调组合式空调机组、通信机柜、医疗与实验室设备、焊接与数控机床机壳,以及新能源电力柜。在这些场景中,风机都是关键部件:一旦故障就意味着停产、货物受损或代价高昂的紧急停机。
一个反复出现的场景来自控制柜改造:原装风机已停产,安装孔位不能改动,停机时间以小时计。我们按机壳尺寸、风量和噪音将旧型号与在产系列逐一比对,提出最接近的直接替换方案,并随货附上规格书,让电工无需重新设计即可接线。
对冷库运营方来说,痛点很直接:蒸发器或冷凝器风机故障必须立即更换,而不是等六周的进口周期。将叶轮直径、转速和防护等级与现货等效型号逐一比对,我们能在几天内恢复制冷能力——备件替换供应也因此成为我们在该分类下的核心业务。
无论您是在制造新设备还是维护既有设备,流程都一样:把工作点和约束条件发给我们,我们回报经过验证的选型结果,并附规格书、性能曲线和明确的交期。
常规系列和主流电压版本通常备有现货,可在几个工作日内发货;特殊或定制版本按订单生产,一般需要额外的生产时间。您只需提供确切型号或所需参数,我们将在一次回复中确认库存、单价和最早发货日期,该分类目前在线展示 642 件产品。
可以。备件替换供应是我们的核心服务之一:我们会逐一核对您在用机组的安装尺寸、电压、转速和性能曲线,提出最接近的在产系列等效型号。如机壳或接口略有差异,我们会在下单前明确告知差异,确保替换安装不出现意外。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。