获取报价
首页 > 产品 > 按类型 > 鼓风机 > AFB1212HHE | Delta Electronics 12VDC 5.52W Axial Fan for Server and Power Supply Cooling

AFB1212HHE Delta 鼓风机

品牌:
Delta
型号:
AFB1212HHE | Delta Electronics 12VDC 5.52W Axial Fan for Server and Power Supply Cooling
类型:
鼓风机
应用行业:
数据中心冷却
产品描述:

The 2900 rpm AFB1212HHE is a 12VDC axial fan intended for server ventilation. With 5.52 W listed input, it differs from the faster SHE and GHE entries; allow for its 120 mm square frame and 38 mm body depth.

规格书:
AFB1212HHE | Delta Electronics 12VDC 5.52W Axial Fan for Server and Power Supply Cooling 规格书 (Pdf)

产品特点

Rated Voltage(V)12
Size(mm)120*120*38
Max.Air Flow(m³/h)204
Max.Pressure(Pa)88.3
Input Power(W)5.52
Speed(rpm)2900
Noise(db)44

产品特点

DC Equipment Cooling

AFB1212HHE is a Delta cooling solution for server and storage equipment. This brushless DC axial fan gives designers a practical means of circulating air through a thermally loaded equipment section.

A listed speed of 2900 rpm helps define the operating profile when reviewing airflow demand, mechanical mounting and the enclosure's acoustic target. The series combines ball-bearing construction with UL 94V-0 materials, addressing mechanical durability and component flammability requirements. Matching the fan curve to the finished air path supports efficient cooling; free-air flow alone does not determine installed performance.

For procurement, retain the complete model code and check the interface against the drawing; this supports repeatable assembly and accurate replacement ordering.

应用行业

常见问题

Why choose AFB1212HHE over a general-purpose fan?

AFB1212HHE provides a defined axial fan format with a listed 2900 rpm speed in a 120 x 120 x 38 mm size. Compare its fan curve with the actual duty point rather than assuming a universal advantage.

What installation space is required for AFB1212HHE?

The workbook lists 120 x 120 x 38 mm. Confirm overall depth, hole pattern, connector clearance and guard or inlet-ring dimensions in the exact mechanical drawing.

Can AFB1212HHE run continuously in 24/7 equipment?

The supplied filter data does not establish an unconditional 24/7 rating. Confirm bearing life, temperature range, duty cycle and derating in the exact datasheet, then validate system-level redundancy.

How should the pressure capability of AFB1212HHE be checked?

The workbook lists 88.3 Pa maximum pressure. Maximum pressure and maximum airflow occur at different points, so select AFB1212HHE from its curve at the required system resistance.

What equipment is AFB1212HHE intended to cool?

AFB1212HHE is listed for Server and Power Supply cooling. Confirm the installed airflow demand, pressure loss and ambient conditions before approval.