1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
EF80252S2-10000-A99 | SUNON 24V 1.01W 80x80x25mm DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, SUNON EF80252S2-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. Its 2900 rpm rating defines a lower-speed operating point. Review its thermal-duty record during heat-load assessment. Use the latest specification for frequency and tolerance limits.

24 80x80x25mm 62.9 37.4 1.01 2900 30
EF80252S1-10000-A99 | SUNON 24V 1.32W 80x80x25mm DC Axial Fan for Refrigeration Equipment

SUNON configures EF80252S1-10000-A99 as a 80 × 80 × 25 mm DC axial fan for telecom cabinets, base stations, and network equipment, operating at 24 VDC. Its 3200 rpm rating defines a lower-speed operating point. Treat the performance curve as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits.

24 80x80x25mm 69.7 44.8 1.32 3200 33
EF80252BX-10000-A99 | SUNON 24V 1.71W 80x80x25mm DC Axial Fan for Refrigeration Equipment

The EF80252BX-10000-A99 is SUNON's 24 VDC, 80 × 80 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3600 rpm rating defines a lower-speed operating point. Base heat-load assessment on the stated mounting size. Use the latest specification for frequency and tolerance limits.

24 80x80x25mm 76.5 57.3 1.71 3600 36.1
EF80252B3-10000-A99 | SUNON 24V 0.89W 80x80x25mm DC Axial Fan for Refrigeration Equipment

The 24 VDC SUNON EF80252B3-10000-A99 is a DC axial fan sized 80 × 80 × 25 mm for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. During heat-load assessment, compare the model's supply requirement. Use the latest specification for frequency and tolerance limits.

24 80x80x25mm 56.1 27.4 0.89 2600 28
EF80252B2-10000-A99 | SUNON 24V 1.16W 80x80x25mm DC Axial Fan for Refrigeration Equipment

SUNON EF80252B2-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for telecom cabinets, base stations, and network equipment. Its 2900 rpm rating defines a lower-speed operating point. The recorded static-pressure entry should guide heat-load assessment. Use the latest specification for frequency and tolerance limits.

24 80x80x25mm 62.9 37.4 1.16 2900 30
EF80252B1-10000-A99 | SUNON 24V 1.56W 80x80x25mm DC Axial Fan for Refrigeration Equipment

Sized for telecom cabinets, base stations, and network equipment, SUNON EF80252B1-10000-A99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 3200 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied volume-flow figure. Use the latest specification for frequency and tolerance limits.

24 80x80x25mm 69.7 44.8 1.56 3200 33
EF80251S3-10000-A99 | SUNON 12V 0.84W 80x80x25mm DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, SUNON EF80251S3-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 12 VDC. Its 2600 rpm rating defines a lower-speed operating point. Use the documented sound level when planning heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 80x80x25mm 56.1 27.4 0.84 2600 28
EF80251S2-10000-A99 | SUNON 12V 1.14W 80x80x25mm DC Axial Fan for Refrigeration Equipment

Specified at 12 VDC, EF80251S2-10000-A99 is a SUNON DC axial fan for telecom cabinets, base stations, and network equipment in 80 × 80 × 25 mm dimensions. Its 2900 rpm rating defines a lower-speed operating point. Review its rotational rating during heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 80x80x25mm 62.9 37.4 1.14 2900 30
EF80251S1-10000-A99 | SUNON 12V 1.44W 80x80x25mm DC Axial Fan for Refrigeration Equipment

The EF80251S1-10000-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3200 rpm rating defines a lower-speed operating point. Treat the power demand as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 80x80x25mm 69.7 44.8 1.44 3200 33
EF80251BX-10000-A99 | SUNON 12V 1.47W 80x80x25mm DC Axial Fan for Refrigeration Equipment

Built for telecom cabinets, base stations, and network equipment, SUNON EF80251BX-10000-A99 uses a 80 × 80 × 25 mm DC axial fan arrangement at 12 VDC. Its 3600 rpm rating defines a lower-speed operating point. Base heat-load assessment on the stated frame geometry. Use the latest specification for frequency and tolerance limits.

12 80x80x25mm 76.5 57.3 1.47 3600 36.1
EF80251B3-10000-A99 | SUNON 12V 0.78W 80x80x25mm DC Axial Fan for Refrigeration Equipment

SUNON EF80251B3-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. During heat-load assessment, compare the model's cooling output. Use the latest specification for frequency and tolerance limits.

12 80x80x25mm 56.1 27.4 0.78 2600 28
EF80251B2-10000-A99 | SUNON 12V 1.08W 80x80x25mm DC Axial Fan for Refrigeration Equipment

Designed for telecom cabinets, base stations, and network equipment, SUNON EF80251B2-10000-A99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 2900 rpm rating defines a lower-speed operating point. The recorded operating point should guide heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 80x80x25mm 62.9 37.4 1.08 2900 30
EF80251B1-10000-A99 | SUNON 12V 1.5W 80x80x25mm 3200rpm DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, SUNON EF80251B1-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 12 VDC. Its 3200 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied pressure capability. Use the latest specification for frequency and tolerance limits.

12 80x80x25mm 69.7 44.8 1.5 3200 33
EF80151S3-10000-999 | SUNON 12V 1.05W 80x80x15mm 51m3/h DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, EF80151S3-10000-999 provides a 80 × 80 × 15 mm, 12 VDC DC axial fan configuration. Its 2800 rpm rating defines a lower-speed operating point. Use the documented dimensional envelope when planning heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 80x80x15mm 51 27.4 1.05 2800 26.5
EF80151S2-10000-999 | SUNON 12V 1.26W 80x80x15mm DC Axial Fan for Refrigeration Equipment

The EF80151S2-10000-999 is SUNON's 12 VDC, 80 × 80 × 15 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3100 rpm rating defines a lower-speed operating point. Review its acoustic value during heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 80x80x15mm 57.1 32.4 1.26 3100 29.9
EF80151S1-10000-999 | SUNON 12V 1.78W 80x80x15mm DC Axial Fan for Refrigeration Equipment

EF80151S1-10000-999 serves telecom cabinets, base stations, and network equipment as a 80 × 80 × 15 mm DC axial fan rated at 12 VDC. Its 3500 rpm rating defines a lower-speed operating point. Treat the electrical load as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 80x80x15mm 62.9 42.3 1.78 3500 32.9
EF60252S1-10000-A99 | SUNON 24V 1.2W 60x60x25mm 4500rpm DC Axial Fan for Refrigeration Equipment

SUNON EF60252S1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 24 VDC rating for telecom cabinets, base stations, and network equipment. A listed noise value of 27 dB is the model's key differentiator. Base heat-load assessment on the stated speed benchmark. Use the latest specification for frequency and tolerance limits.

24 60x60x25mm 39.9 52.3 1.2 4500 27
EF60252B1-10000-A99 | SUNON 24V 1.08W 60x60x25mm DC Axial Fan for Refrigeration Equipment

Used in telecom cabinets, base stations, and network equipment, SUNON EF60252B1-10000-A99 is a 24 VDC DC axial fan in a 60 × 60 × 25 mm frame. A listed input of 1.08 W is the model's notable electrical characteristic. During heat-load assessment, compare the model's airflow profile. Use the latest specification for frequency and tolerance limits.

24 60x60x25mm 39.9 54.8 1.08 5200 31.5
EF60251B3-10000-A99 | SUNON 12V 0.46W 60x60x25mm DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, SUNON EF60251B3-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. A listed noise value of 20 dB is the model's key differentiator. The recorded application data should guide airflow balancing. Review connector, alarm, and sensor options separately.

12 60x60x25mm 23.6 24.9 0.46 3400 20
EF60251B2-10000-A99 | SUNON 12V 0.7W 60x60x25mm 4500rpm DC Axial Fan for Refrigeration Equipment

The 60 × 60 × 25 mm EF60251B2-10000-A99 brings 12 VDC DC axial fan cooling to telecom cabinets, base stations, and network equipment. A listed input of 0.7 W is the model's notable electrical characteristic. For airflow balancing, start with the supplied technical profile. Review connector, alarm, and sensor options separately.

12 60x60x25mm 32.8 42.3 0.7 4500 27
显示
181-200
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
1 2 ... 7 8 9 10 11 12 13 ... 50 51
跳转 页

关于DC粉丝

如何选择合适的DC粉丝

确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。

DC粉丝的典型应用场景与案例

我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

DC粉丝采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持DC粉丝的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。