| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EF80252S2-10000-A99 | SUNON 24V 1.01W 80x80x25mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EF80252S2-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. Its 2900 rpm rating defines a lower-speed operating point. Review its thermal-duty record during heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 80x80x25mm | 62.9 | 37.4 | 1.01 | 2900 | 30 | |
![]() EF80252S1-10000-A99 | SUNON 24V 1.32W 80x80x25mm DC Axial Fan for Refrigeration Equipment SUNON configures EF80252S1-10000-A99 as a 80 × 80 × 25 mm DC axial fan for telecom cabinets, base stations, and network equipment, operating at 24 VDC. Its 3200 rpm rating defines a lower-speed operating point. Treat the performance curve as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 80x80x25mm | 69.7 | 44.8 | 1.32 | 3200 | 33 | |
![]() EF80252BX-10000-A99 | SUNON 24V 1.71W 80x80x25mm DC Axial Fan for Refrigeration Equipment The EF80252BX-10000-A99 is SUNON's 24 VDC, 80 × 80 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3600 rpm rating defines a lower-speed operating point. Base heat-load assessment on the stated mounting size. Use the latest specification for frequency and tolerance limits. |
24 | 80x80x25mm | 76.5 | 57.3 | 1.71 | 3600 | 36.1 | |
![]() EF80252B3-10000-A99 | SUNON 24V 0.89W 80x80x25mm DC Axial Fan for Refrigeration Equipment The 24 VDC SUNON EF80252B3-10000-A99 is a DC axial fan sized 80 × 80 × 25 mm for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. During heat-load assessment, compare the model's supply requirement. Use the latest specification for frequency and tolerance limits. |
24 | 80x80x25mm | 56.1 | 27.4 | 0.89 | 2600 | 28 | |
![]() EF80252B2-10000-A99 | SUNON 24V 1.16W 80x80x25mm DC Axial Fan for Refrigeration Equipment SUNON EF80252B2-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for telecom cabinets, base stations, and network equipment. Its 2900 rpm rating defines a lower-speed operating point. The recorded static-pressure entry should guide heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 80x80x25mm | 62.9 | 37.4 | 1.16 | 2900 | 30 | |
![]() EF80252B1-10000-A99 | SUNON 24V 1.56W 80x80x25mm DC Axial Fan for Refrigeration Equipment Sized for telecom cabinets, base stations, and network equipment, SUNON EF80252B1-10000-A99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 3200 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied volume-flow figure. Use the latest specification for frequency and tolerance limits. |
24 | 80x80x25mm | 69.7 | 44.8 | 1.56 | 3200 | 33 | |
![]() EF80251S3-10000-A99 | SUNON 12V 0.84W 80x80x25mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EF80251S3-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 12 VDC. Its 2600 rpm rating defines a lower-speed operating point. Use the documented sound level when planning heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x25mm | 56.1 | 27.4 | 0.84 | 2600 | 28 | |
![]() EF80251S2-10000-A99 | SUNON 12V 1.14W 80x80x25mm DC Axial Fan for Refrigeration Equipment Specified at 12 VDC, EF80251S2-10000-A99 is a SUNON DC axial fan for telecom cabinets, base stations, and network equipment in 80 × 80 × 25 mm dimensions. Its 2900 rpm rating defines a lower-speed operating point. Review its rotational rating during heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x25mm | 62.9 | 37.4 | 1.14 | 2900 | 30 | |
![]() EF80251S1-10000-A99 | SUNON 12V 1.44W 80x80x25mm DC Axial Fan for Refrigeration Equipment The EF80251S1-10000-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3200 rpm rating defines a lower-speed operating point. Treat the power demand as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x25mm | 69.7 | 44.8 | 1.44 | 3200 | 33 | |
![]() EF80251BX-10000-A99 | SUNON 12V 1.47W 80x80x25mm DC Axial Fan for Refrigeration Equipment Built for telecom cabinets, base stations, and network equipment, SUNON EF80251BX-10000-A99 uses a 80 × 80 × 25 mm DC axial fan arrangement at 12 VDC. Its 3600 rpm rating defines a lower-speed operating point. Base heat-load assessment on the stated frame geometry. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x25mm | 76.5 | 57.3 | 1.47 | 3600 | 36.1 | |
![]() EF80251B3-10000-A99 | SUNON 12V 0.78W 80x80x25mm DC Axial Fan for Refrigeration Equipment SUNON EF80251B3-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2600 rpm rating defines a lower-speed operating point. During heat-load assessment, compare the model's cooling output. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x25mm | 56.1 | 27.4 | 0.78 | 2600 | 28 | |
![]() EF80251B2-10000-A99 | SUNON 12V 1.08W 80x80x25mm DC Axial Fan for Refrigeration Equipment Designed for telecom cabinets, base stations, and network equipment, SUNON EF80251B2-10000-A99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 2900 rpm rating defines a lower-speed operating point. The recorded operating point should guide heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x25mm | 62.9 | 37.4 | 1.08 | 2900 | 30 | |
![]() EF80251B1-10000-A99 | SUNON 12V 1.5W 80x80x25mm 3200rpm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EF80251B1-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 12 VDC. Its 3200 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied pressure capability. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x25mm | 69.7 | 44.8 | 1.5 | 3200 | 33 | |
![]() EF80151S3-10000-999 | SUNON 12V 1.05W 80x80x15mm 51m3/h DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, EF80151S3-10000-999 provides a 80 × 80 × 15 mm, 12 VDC DC axial fan configuration. Its 2800 rpm rating defines a lower-speed operating point. Use the documented dimensional envelope when planning heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x15mm | 51 | 27.4 | 1.05 | 2800 | 26.5 | |
![]() EF80151S2-10000-999 | SUNON 12V 1.26W 80x80x15mm DC Axial Fan for Refrigeration Equipment The EF80151S2-10000-999 is SUNON's 12 VDC, 80 × 80 × 15 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 3100 rpm rating defines a lower-speed operating point. Review its acoustic value during heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x15mm | 57.1 | 32.4 | 1.26 | 3100 | 29.9 | |
![]() EF80151S1-10000-999 | SUNON 12V 1.78W 80x80x15mm DC Axial Fan for Refrigeration Equipment EF80151S1-10000-999 serves telecom cabinets, base stations, and network equipment as a 80 × 80 × 15 mm DC axial fan rated at 12 VDC. Its 3500 rpm rating defines a lower-speed operating point. Treat the electrical load as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 80x80x15mm | 62.9 | 42.3 | 1.78 | 3500 | 32.9 | |
![]() EF60252S1-10000-A99 | SUNON 24V 1.2W 60x60x25mm 4500rpm DC Axial Fan for Refrigeration Equipment SUNON EF60252S1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 24 VDC rating for telecom cabinets, base stations, and network equipment. A listed noise value of 27 dB is the model's key differentiator. Base heat-load assessment on the stated speed benchmark. Use the latest specification for frequency and tolerance limits. |
24 | 60x60x25mm | 39.9 | 52.3 | 1.2 | 4500 | 27 | |
![]() EF60252B1-10000-A99 | SUNON 24V 1.08W 60x60x25mm DC Axial Fan for Refrigeration Equipment Used in telecom cabinets, base stations, and network equipment, SUNON EF60252B1-10000-A99 is a 24 VDC DC axial fan in a 60 × 60 × 25 mm frame. A listed input of 1.08 W is the model's notable electrical characteristic. During heat-load assessment, compare the model's airflow profile. Use the latest specification for frequency and tolerance limits. |
24 | 60x60x25mm | 39.9 | 54.8 | 1.08 | 5200 | 31.5 | |
![]() EF60251B3-10000-A99 | SUNON 12V 0.46W 60x60x25mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EF60251B3-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. A listed noise value of 20 dB is the model's key differentiator. The recorded application data should guide airflow balancing. Review connector, alarm, and sensor options separately. |
12 | 60x60x25mm | 23.6 | 24.9 | 0.46 | 3400 | 20 | |
![]() EF60251B2-10000-A99 | SUNON 12V 0.7W 60x60x25mm 4500rpm DC Axial Fan for Refrigeration Equipment The 60 × 60 × 25 mm EF60251B2-10000-A99 brings 12 VDC DC axial fan cooling to telecom cabinets, base stations, and network equipment. A listed input of 0.7 W is the model's notable electrical characteristic. For airflow balancing, start with the supplied technical profile. Review connector, alarm, and sensor options separately. |
12 | 60x60x25mm | 32.8 | 42.3 | 0.7 | 4500 | 27 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。