获取报价
首页 > 产品 > 按品牌 > SUNON > DC粉丝

DC粉丝

按类型

按行业

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

库存选项

环保选项

资料

排除

1,011 个结果

已选条件

显示
161-180
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
GE80252B1-0000-AE9 | SUNON 24V 4.8W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling

Within industrial electronics and equipment cooling, GE80252B1-0000-AE9 provides a 80 × 80 × 25 mm, 24 VDC DC axial fan configuration. 102.1 Pa maximum pressure is the standout documented duty-point value. Treat the dimensional envelope as a primary input to specification approval. Check the ordering suffix before assigning control functions.

24 80x80x25mm 101.9 102.1 4.8 4800 47.5
GE80252B1-0000-AC9 | SUNON 24V 4.8W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling

Positioned for industrial electronics and equipment cooling, SUNON GE80252B1-0000-AC9 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. 102.1 Pa maximum pressure is the standout documented duty-point value. Base specification approval on the stated acoustic value. Check the ordering suffix before assigning control functions.

24 80x80x25mm 101.9 102.1 4.8 4800 47.5
GE80252B1-000U-AE9 | SUNON 24V 4.8W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling

Within industrial electronics and equipment cooling, SUNON GE80252B1-000U-AE9 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. During specification approval, compare the model's electrical load. Check the ordering suffix before assigning control functions.

24 80x80x25mm 101.9 102.1 4.8 4800 47.5
EFC0382B3-10000-A9H | SUNON 24V 1.8W 120x120x38mm DC Axial Fan for Refrigeration Equipment

For telecom cabinets, base stations, and network equipment, EFC0382B3-10000-A9H combines 24 VDC operation with a 120 × 120 × 38 mm DC axial fan design. Its 2400 rpm rating defines a lower-speed operating point. The recorded speed benchmark should guide specification approval. Check the ordering suffix before assigning control functions.

24 120x120x38mm 158 47.3 1.8 2400 36
EFC0382B2-10000-A9H | SUNON 24V 3.24W 120x120x38mm DC Axial Fan for Refrigeration Equipment

The EFC0382B2-10000-A9H is SUNON's 24 VDC, 120 × 120 × 38 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. For specification approval, start with the supplied airflow profile. Check the ordering suffix before assigning control functions.

24 120x120x38mm 197.1 72.2 3.24 3100 43.2
EFC0382B1-10000-A9H | SUNON 24V 4.68W 120x120x38mm DC Axial Fan for Refrigeration Equipment

SUNON EFC0382B1-10000-A9H is a 24 VDC DC axial fan for telecom cabinets, base stations, and network equipment. Up to 234.5 m³/h is its most prominent listed performance figure. Use the documented application data when planning heat-load assessment. Use the latest specification for frequency and tolerance limits.

24 120x120x38mm 234.5 99.6 4.68 3700 48
EFC0381B3-10000-A9H | SUNON 12V 1.5W 120x120x38mm DC Axial Fan for Refrigeration Equipment

SUNON EFC0381B3-10000-A9H combines a 120 × 120 × 38 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2400 rpm rating defines a lower-speed operating point. Review its technical profile during heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 120x120x38mm 158 47.3 1.5 2400 36
EFC0381B2-10000-A9H | SUNON 12V 2.94W 120x120x38mm DC Axial Fan for Refrigeration Equipment

Built around telecom cabinets, base stations, and network equipment, SUNON EFC0381B2-10000-A9H is a 12 VDC DC axial fan in a 120 × 120 × 38 mm frame. Up to 197.1 m³/h is its most prominent listed performance figure. Treat the model record as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 120x120x38mm 197.1 72.2 2.94 3100 43.2
EFC0381B1-10000-A9H | SUNON 12V 4.26W 120x120x38mm DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, SUNON EFC0381B1-10000-A9H serves as a 120 × 120 × 38 mm DC axial fan operating at 12 VDC. Up to 234.5 m³/h is its most prominent listed performance figure. Base heat-load assessment on the stated product configuration. Use the latest specification for frequency and tolerance limits.

12 120x120x38mm 234.5 99.6 4.26 3700 48
EF92252S1-10000-A99 | SUNON 24V 1.44W 92x92x25mm DC Axial Fan for Refrigeration Equipment

A 92 × 92 × 25 mm frame and 24 VDC rating define EF92252S1-10000-A99, a DC axial fan for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. During heat-load assessment, compare the model's system interface. Use the latest specification for frequency and tolerance limits.

24 92x92x25mm 87.5 37.4 1.44 3000 34
EF92252BX-10000-A99 | SUNON 24V 2.16W 92x92x25mm DC Axial Fan for Refrigeration Equipment

The EF92252BX-10000-A99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 93.4 m³/h is its most prominent listed performance figure. The recorded cooling specification should guide heat-load assessment. Use the latest specification for frequency and tolerance limits.

24 92x92x25mm 93.4 52.3 2.16 3400 36.9
EF92252B2-10000-A99 | SUNON 24V 1.08W 92x92x25mm DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, EF92252B2-10000-A99 provides a 92 × 92 × 25 mm, 24 VDC DC axial fan configuration. Its 2700 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied duty-point values. Use the latest specification for frequency and tolerance limits.

24 92x92x25mm 76.5 37.4 1.08 2700 32
EF92252B1-10000-A99 | SUNON 24V 1.52W 92x92x25mm DC Axial Fan for Refrigeration Equipment

The 24 VDC SUNON EF92252B1-10000-A99 is a DC axial fan sized 92 × 92 × 25 mm for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Use the documented installation footprint when planning heat-load assessment. Use the latest specification for frequency and tolerance limits.

24 92x92x25mm 87.5 42.3 1.52 3000 34
EF92251S3-10000-A99 | SUNON 12V 0.96W 92x92x25mm DC Axial Fan for Refrigeration Equipment

Configured for telecom cabinets, base stations, and network equipment, SUNON EF92251S3-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 2400 rpm rating defines a lower-speed operating point. Review its selection parameters during heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 92x92x25mm 67.1 24.9 0.96 2400 28
EF92251S2-10000-A99 | SUNON 12V 1.32W 92x92x25mm DC Axial Fan for Refrigeration Equipment

Within telecom cabinets, base stations, and network equipment, SUNON EF92251S2-10000-A99 serves as a 92 × 92 × 25 mm DC axial fan operating at 12 VDC. Its 2700 rpm rating defines a lower-speed operating point. Treat the rated dataset as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 92x92x25mm 76.5 32.4 1.32 2700 32
EF92251S1-10000-A99 | SUNON 12V 1.68W 92x92x25mm DC Axial Fan for Refrigeration Equipment

SUNON EF92251S1-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm format for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Base heat-load assessment on the stated motor input. Use the latest specification for frequency and tolerance limits.

12 92x92x25mm 87.5 37.4 1.68 3000 34
EF92251BX-10000-A99 | SUNON 12V 1.62W 92x92x25mm DC Axial Fan for Refrigeration Equipment

The EF92251BX-10000-A99 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 93.4 m³/h is its most prominent listed performance figure. During heat-load assessment, compare the model's ventilation capacity. Use the latest specification for frequency and tolerance limits.

12 92x92x25mm 93.4 52.3 1.62 3400 36.9
EF92251B3-10000-A99 | SUNON 12V 0.75W 92x92x25mm DC Axial Fan for Refrigeration Equipment

The 92 × 92 × 25 mm EF92251B3-10000-A99 brings 12 VDC DC axial fan cooling to telecom cabinets, base stations, and network equipment. Its 2400 rpm rating defines a lower-speed operating point. The recorded equipment fit should guide heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 92x92x25mm 67.1 29.9 0.75 2400 28
EF92251B2-10000-A99 | SUNON 12V 1.08W 92x92x25mm DC Axial Fan for Refrigeration Equipment

SUNON EF92251B2-10000-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2700 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied suffix definition. Use the latest specification for frequency and tolerance limits.

12 92x92x25mm 76.5 37.4 1.08 2700 32
EF92251B1-10000-A99 | SUNON 12V 1.5W 92x92x25mm 3000rpm DC Axial Fan for Refrigeration Equipment

Engineered for telecom cabinets, base stations, and network equipment, SUNON EF92251B1-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 3000 rpm rating defines a lower-speed operating point. Use the documented catalog specification when planning heat-load assessment. Use the latest specification for frequency and tolerance limits.

12 92x92x25mm 87.5 42.3 1.5 3000 34
显示
161-180
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
1 2 ... 6 7 8 9 10 11 12 ... 50 51
跳转 页

关于DC粉丝

如何选择合适的DC粉丝

确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。

DC粉丝的典型应用场景与案例

我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

DC粉丝采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持DC粉丝的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。