| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() GE80252B1-0000-AE9 | SUNON 24V 4.8W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling Within industrial electronics and equipment cooling, GE80252B1-0000-AE9 provides a 80 × 80 × 25 mm, 24 VDC DC axial fan configuration. 102.1 Pa maximum pressure is the standout documented duty-point value. Treat the dimensional envelope as a primary input to specification approval. Check the ordering suffix before assigning control functions. |
24 | 80x80x25mm | 101.9 | 102.1 | 4.8 | 4800 | 47.5 | |
![]() GE80252B1-0000-AC9 | SUNON 24V 4.8W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling Positioned for industrial electronics and equipment cooling, SUNON GE80252B1-0000-AC9 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. 102.1 Pa maximum pressure is the standout documented duty-point value. Base specification approval on the stated acoustic value. Check the ordering suffix before assigning control functions. |
24 | 80x80x25mm | 101.9 | 102.1 | 4.8 | 4800 | 47.5 | |
![]() GE80252B1-000U-AE9 | SUNON 24V 4.8W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling Within industrial electronics and equipment cooling, SUNON GE80252B1-000U-AE9 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. During specification approval, compare the model's electrical load. Check the ordering suffix before assigning control functions. |
24 | 80x80x25mm | 101.9 | 102.1 | 4.8 | 4800 | 47.5 | |
![]() EFC0382B3-10000-A9H | SUNON 24V 1.8W 120x120x38mm DC Axial Fan for Refrigeration Equipment For telecom cabinets, base stations, and network equipment, EFC0382B3-10000-A9H combines 24 VDC operation with a 120 × 120 × 38 mm DC axial fan design. Its 2400 rpm rating defines a lower-speed operating point. The recorded speed benchmark should guide specification approval. Check the ordering suffix before assigning control functions. |
24 | 120x120x38mm | 158 | 47.3 | 1.8 | 2400 | 36 | |
![]() EFC0382B2-10000-A9H | SUNON 24V 3.24W 120x120x38mm DC Axial Fan for Refrigeration Equipment The EFC0382B2-10000-A9H is SUNON's 24 VDC, 120 × 120 × 38 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. For specification approval, start with the supplied airflow profile. Check the ordering suffix before assigning control functions. |
24 | 120x120x38mm | 197.1 | 72.2 | 3.24 | 3100 | 43.2 | |
![]() EFC0382B1-10000-A9H | SUNON 24V 4.68W 120x120x38mm DC Axial Fan for Refrigeration Equipment SUNON EFC0382B1-10000-A9H is a 24 VDC DC axial fan for telecom cabinets, base stations, and network equipment. Up to 234.5 m³/h is its most prominent listed performance figure. Use the documented application data when planning heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 120x120x38mm | 234.5 | 99.6 | 4.68 | 3700 | 48 | |
![]() EFC0381B3-10000-A9H | SUNON 12V 1.5W 120x120x38mm DC Axial Fan for Refrigeration Equipment SUNON EFC0381B3-10000-A9H combines a 120 × 120 × 38 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2400 rpm rating defines a lower-speed operating point. Review its technical profile during heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 120x120x38mm | 158 | 47.3 | 1.5 | 2400 | 36 | |
![]() EFC0381B2-10000-A9H | SUNON 12V 2.94W 120x120x38mm DC Axial Fan for Refrigeration Equipment Built around telecom cabinets, base stations, and network equipment, SUNON EFC0381B2-10000-A9H is a 12 VDC DC axial fan in a 120 × 120 × 38 mm frame. Up to 197.1 m³/h is its most prominent listed performance figure. Treat the model record as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 120x120x38mm | 197.1 | 72.2 | 2.94 | 3100 | 43.2 | |
![]() EFC0381B1-10000-A9H | SUNON 12V 4.26W 120x120x38mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EFC0381B1-10000-A9H serves as a 120 × 120 × 38 mm DC axial fan operating at 12 VDC. Up to 234.5 m³/h is its most prominent listed performance figure. Base heat-load assessment on the stated product configuration. Use the latest specification for frequency and tolerance limits. |
12 | 120x120x38mm | 234.5 | 99.6 | 4.26 | 3700 | 48 | |
![]() EF92252S1-10000-A99 | SUNON 24V 1.44W 92x92x25mm DC Axial Fan for Refrigeration Equipment A 92 × 92 × 25 mm frame and 24 VDC rating define EF92252S1-10000-A99, a DC axial fan for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. During heat-load assessment, compare the model's system interface. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 87.5 | 37.4 | 1.44 | 3000 | 34 | |
![]() EF92252BX-10000-A99 | SUNON 24V 2.16W 92x92x25mm DC Axial Fan for Refrigeration Equipment The EF92252BX-10000-A99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 93.4 m³/h is its most prominent listed performance figure. The recorded cooling specification should guide heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 93.4 | 52.3 | 2.16 | 3400 | 36.9 | |
![]() EF92252B2-10000-A99 | SUNON 24V 1.08W 92x92x25mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, EF92252B2-10000-A99 provides a 92 × 92 × 25 mm, 24 VDC DC axial fan configuration. Its 2700 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied duty-point values. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 76.5 | 37.4 | 1.08 | 2700 | 32 | |
![]() EF92252B1-10000-A99 | SUNON 24V 1.52W 92x92x25mm DC Axial Fan for Refrigeration Equipment The 24 VDC SUNON EF92252B1-10000-A99 is a DC axial fan sized 92 × 92 × 25 mm for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Use the documented installation footprint when planning heat-load assessment. Use the latest specification for frequency and tolerance limits. |
24 | 92x92x25mm | 87.5 | 42.3 | 1.52 | 3000 | 34 | |
![]() EF92251S3-10000-A99 | SUNON 12V 0.96W 92x92x25mm DC Axial Fan for Refrigeration Equipment Configured for telecom cabinets, base stations, and network equipment, SUNON EF92251S3-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 2400 rpm rating defines a lower-speed operating point. Review its selection parameters during heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 67.1 | 24.9 | 0.96 | 2400 | 28 | |
![]() EF92251S2-10000-A99 | SUNON 12V 1.32W 92x92x25mm DC Axial Fan for Refrigeration Equipment Within telecom cabinets, base stations, and network equipment, SUNON EF92251S2-10000-A99 serves as a 92 × 92 × 25 mm DC axial fan operating at 12 VDC. Its 2700 rpm rating defines a lower-speed operating point. Treat the rated dataset as a primary input to heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 76.5 | 32.4 | 1.32 | 2700 | 32 | |
![]() EF92251S1-10000-A99 | SUNON 12V 1.68W 92x92x25mm DC Axial Fan for Refrigeration Equipment SUNON EF92251S1-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm format for telecom cabinets, base stations, and network equipment. Its 3000 rpm rating defines a lower-speed operating point. Base heat-load assessment on the stated motor input. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 87.5 | 37.4 | 1.68 | 3000 | 34 | |
![]() EF92251BX-10000-A99 | SUNON 12V 1.62W 92x92x25mm DC Axial Fan for Refrigeration Equipment The EF92251BX-10000-A99 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Up to 93.4 m³/h is its most prominent listed performance figure. During heat-load assessment, compare the model's ventilation capacity. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 93.4 | 52.3 | 1.62 | 3400 | 36.9 | |
![]() EF92251B3-10000-A99 | SUNON 12V 0.75W 92x92x25mm DC Axial Fan for Refrigeration Equipment The 92 × 92 × 25 mm EF92251B3-10000-A99 brings 12 VDC DC axial fan cooling to telecom cabinets, base stations, and network equipment. Its 2400 rpm rating defines a lower-speed operating point. The recorded equipment fit should guide heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 67.1 | 29.9 | 0.75 | 2400 | 28 | |
![]() EF92251B2-10000-A99 | SUNON 12V 1.08W 92x92x25mm DC Axial Fan for Refrigeration Equipment SUNON EF92251B2-10000-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2700 rpm rating defines a lower-speed operating point. For heat-load assessment, start with the supplied suffix definition. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 76.5 | 37.4 | 1.08 | 2700 | 32 | |
![]() EF92251B1-10000-A99 | SUNON 12V 1.5W 92x92x25mm 3000rpm DC Axial Fan for Refrigeration Equipment Engineered for telecom cabinets, base stations, and network equipment, SUNON EF92251B1-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 3000 rpm rating defines a lower-speed operating point. Use the documented catalog specification when planning heat-load assessment. Use the latest specification for frequency and tolerance limits. |
12 | 92x92x25mm | 87.5 | 42.3 | 1.5 | 3000 | 34 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。