获取报价
首页 > 产品 > 按品牌 > SUNON > DC粉丝

DC粉丝

按类型

按行业

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

库存选项

环保选项

资料

排除

1,011 个结果

已选条件

显示
381-400
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
GF92382BX-10000-QDP | SUNON 24V 9000W 40x40x28mm 293.8m3/h 9000rpm DC Axial Fan for New Energy

Within inverters, energy-storage systems, and charging equipment, SUNON GF92382BX-10000-QDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 9000 W input is the defining electrical load in the supplied data. For spares assessment, start with the supplied duty-point values. Confirm control inputs against the complete ordering code.

24 40x40x28mm 293.8 430.9 9000 9000 66.8
GF92382BX-10000-AEP | SUNON 24V 40.8W 92x92x38mm 293.8m3/h 9000rpm DC Axial Fan for New Energy

The 24 VDC SUNON GF92382BX-10000-AEP is a DC axial fan sized 92 × 92 × 38 mm for inverters, energy-storage systems, and charging equipment. Up to 293.8 m³/h is its most prominent listed performance figure. Use the documented installation footprint when planning spares assessment. Confirm control inputs against the complete ordering code.

24 92x92x38mm 293.8 430.9 40.8 9000 66.8
GF92382BX-10000-ADP | SUNON 24V 40.8W 92x92x38mm 293.8m3/h 9000rpm DC Axial Fan for New Energy

The GF92382BX-10000-ADP is SUNON's 24 VDC, 92 × 92 × 38 mm DC axial fan option for inverters, energy-storage systems, and charging equipment. Up to 293.8 m³/h is its most prominent listed performance figure. Review its selection parameters during spares assessment. Confirm control inputs against the complete ordering code.

24 92x92x38mm 293.8 430.9 40.8 9000 66.8
GF92382B1-10000-SDP | SUNON 24V 7200W 40x40x28mm 246.9m3/h DC Axial Fan for Industrial Cooling

For airflow duties across servers and data-center electronics, the GF92382B1-10000-SDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 7200 W input is the defining electrical load in the supplied data. Treat the rated dataset as a primary input to spares assessment. Confirm control inputs against the complete ordering code.

24 40x40x28mm 246.9 298.9 7200 7200 60.6
GF92382B1-10000-AEP | SUNON 24V 20.4W 92x92x38mm 246.9m3/h DC Axial Fan for Data Center Cooling

SUNON GF92382B1-10000-AEP combines a 92 × 92 × 38 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Up to 246.9 m³/h is its most prominent listed performance figure. Base spares assessment on the stated motor input. Confirm control inputs against the complete ordering code.

24 92x92x38mm 246.9 298.9 20.4 7200 60.6
GF92382B1-10000-ADP | SUNON 24V 20.4W 92x92x38mm 246.9m3/h DC Axial Fan for Data Center Cooling

Built around servers and data-center electronics, SUNON GF92382B1-10000-ADP is a 24 VDC DC axial fan in a 92 × 92 × 38 mm frame. Up to 246.9 m³/h is its most prominent listed performance figure. During spares assessment, compare the model's ventilation capacity. Confirm control inputs against the complete ordering code.

24 92x92x38mm 246.9 298.9 20.4 7200 60.6
GF92252B7-0000-AE9 | SUNON 24V 1.13W 92x92x25mm 67.1m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON GF92252B7-0000-AE9 serves as a 92 × 92 × 25 mm DC axial fan operating at 24 VDC. Its 2400 rpm rating defines a lower-speed operating point. The recorded equipment fit should guide spares assessment. Confirm control inputs against the complete ordering code.

24 92x92x25mm 67.1 24.9 1.13 2400 28
GF92252B7-0000-AC9 | SUNON 24V 1.13W 92x92x25mm 67.1m3/h DC Axial Fan for Data Center Cooling

Equipment designers working with servers and data-center electronics can evaluate SUNON GF92252B7-0000-AC9, a DC axial fan rated at 24 VDC and sized 92 × 92 × 25 mm. Its 2400 rpm rating defines a lower-speed operating point. For spares assessment, start with the supplied suffix definition. Confirm control inputs against the complete ordering code.

24 92x92x25mm 67.1 24.9 1.13 2400 28
GF92252B6-0000-AE9 | SUNON 24V 1.56W 92x92x25mm 76.5m3/h DC Axial Fan for Data Center Cooling

The GF92252B6-0000-AE9 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Its 2700 rpm rating defines a lower-speed operating point. Use the documented catalog specification when planning spares assessment. Confirm control inputs against the complete ordering code.

24 92x92x25mm 76.5 32.4 1.56 2700 32
GF92252B6-0000-AC9 | SUNON 24V 1.56W 92x92x25mm 76.5m3/h DC Axial Fan for Data Center Cooling

For ventilation needs in servers and data-center electronics, the GF92252B6-0000-AC9 provides a 24 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Its 2700 rpm rating defines a lower-speed operating point. Review its thermal-duty record during spares assessment. Confirm control inputs against the complete ordering code.

24 92x92x25mm 76.5 32.4 1.56 2700 32
GF92252B5-0000-AE9 | SUNON 24V 2.09W 92x92x25mm 87.5m3/h DC Axial Fan for Data Center Cooling

SUNON GF92252B5-0000-AE9 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Its 3000 rpm rating defines a lower-speed operating point. Treat the performance curve as a primary input to spares assessment. Confirm control inputs against the complete ordering code.

24 92x92x25mm 87.5 37.4 2.09 3000 34
GF92252B5-0000-AC9 | SUNON 24V 2.09W 92x92x25mm 87.5m3/h DC Axial Fan for Data Center Cooling

Configured for servers and data-center electronics, SUNON GF92252B5-0000-AC9 is a 24 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 3000 rpm rating defines a lower-speed operating point. Base spares assessment on the stated mounting size. Confirm control inputs against the complete ordering code.

24 92x92x25mm 87.5 37.4 2.09 3000 34
GF92251B7-0000-AE9 | SUNON 12V 1.1W 92x92x25mm 67.1m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON GF92251B7-0000-AE9 serves as a 92 × 92 × 25 mm DC axial fan operating at 12 VDC. Its 2400 rpm rating defines a lower-speed operating point. During spares assessment, compare the model's supply requirement. Confirm control inputs against the complete ordering code.

12 92x92x25mm 67.1 24.9 1.1 2400 28
GF92251B7-0000-AC9 | SUNON 12V 1.1W 92x92x25mm 67.1m3/h DC Axial Fan for Data Center Cooling

Equipment designers working with servers and data-center electronics can evaluate SUNON GF92251B7-0000-AC9, a DC axial fan rated at 12 VDC and sized 92 × 92 × 25 mm. Its 2400 rpm rating defines a lower-speed operating point. The recorded static-pressure entry should guide spares assessment. Confirm control inputs against the complete ordering code.

12 92x92x25mm 67.1 24.9 1.1 2400 28
GF92251B6-0000-AE9 | SUNON 12V 1.62W 92x92x25mm 76.5m3/h DC Axial Fan for Data Center Cooling

The GF92251B6-0000-AE9 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Its 2700 rpm rating defines a lower-speed operating point. For spares assessment, start with the supplied volume-flow figure. Confirm control inputs against the complete ordering code.

12 92x92x25mm 76.5 32.4 1.62 2700 32
GF92251B6-0000-AC9 | SUNON 12V 1.62W 92x92x25mm 76.5m3/h DC Axial Fan for Data Center Cooling

For compact cooling within servers and data-center electronics, the GF92251B6-0000-AC9 provides a 12 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Its 2700 rpm rating defines a lower-speed operating point. Use the documented sound level when planning spares assessment. Confirm control inputs against the complete ordering code.

12 92x92x25mm 76.5 32.4 1.62 2700 32
GF92251B5-0000-AE9 | SUNON 12V 1.98W 92x92x25mm 87.5m3/h DC Axial Fan for Data Center Cooling

SUNON GF92251B5-0000-AE9 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Its 3000 rpm rating defines a lower-speed operating point. Review its rotational rating during spares assessment. Confirm control inputs against the complete ordering code.

12 92x92x25mm 87.5 37.4 1.98 3000 34
GF92251B5-0000-AC9 | SUNON 12V 1.98W 92x92x25mm 87.5m3/h DC Axial Fan for Data Center Cooling

Engineered for servers and data-center electronics, SUNON GF92251B5-0000-AC9 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Its 3000 rpm rating defines a lower-speed operating point. Treat the power demand as a primary input to spares assessment. Confirm control inputs against the complete ordering code.

12 92x92x25mm 87.5 37.4 1.98 3000 34
GF92251B3-0000-AE9 | SUNON 12V 2.76W 92x92x25mm 110.4m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON GF92251B3-0000-AE9 serves as a 92 × 92 × 25 mm DC axial fan operating at 12 VDC. Up to 110.4 m³/h is its most prominent listed performance figure. Base spares assessment on the stated frame geometry. Confirm control inputs against the complete ordering code.

12 92x92x25mm 110.4 62.3 2.76 3900 43
GF92251B3-0000-AC9 | SUNON 12V 2.76W 92x92x25mm 110.4m3/h DC Axial Fan for Data Center Cooling

GF92251B3-0000-AC9 addresses servers and data-center electronics through a 12 VDC DC axial fan platform measuring 92 × 92 × 25 mm. Up to 110.4 m³/h is its most prominent listed performance figure. During spares assessment, compare the model's cooling output. Confirm control inputs against the complete ordering code.

12 92x92x25mm 110.4 62.3 2.76 3900 43
显示
381-400
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
1 2 ... 17 18 19 20 21 22 23 ... 50 51
跳转 页

关于DC粉丝

如何选择合适的DC粉丝

确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。

DC粉丝的典型应用场景与案例

我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

DC粉丝采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持DC粉丝的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。