获取报价
首页 > 产品 > 按品牌 > SUNON > DC粉丝

DC粉丝

按类型

按行业

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

库存选项

环保选项

资料

排除

1,011 个结果

已选条件

显示
341-360
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
PF60252B1-10000-A99 | SUNON 24V 2.57W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling

The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.

24 60x60x25mm 61.2 139.5 2.57 7500 41.7
PF60251VX-10000-A99 | SUNON 12V 4.08W 60x60x25mm 68m3/h DC Axial Fan for Data Center Cooling

For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.

12 60x60x25mm 68 164.4 4.08 8300 46
PF60251V3-10000-A99 | SUNON 12V 1.92W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling

SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.

12 60x60x25mm 49.3 102.1 1.92 6200 37.5
PF60251V2-10000-A99 | SUNON 12V 2.58W 60x60x25mm 53.5m3/h DC Axial Fan for Data Center Cooling

Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.

12 60x60x25mm 53.5 124.5 2.58 7000 40.7
PF60251V1-10000-A99 | SUNON 12V 3.1W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF60251V1-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. 139.5 Pa maximum pressure is the standout documented duty-point value. The recorded product configuration should guide design qualification. Match the exact part number before approving a substitute.

12 60x60x25mm 61.2 139.5 3.1 7500 41.7
PF60251BX-10000-A99 | SUNON 12V 3.24W 60x60x25mm 68m3/h DC Axial Fan for Data Center Cooling

A 60 × 60 × 25 mm frame and 12 VDC rating define PF60251BX-10000-A99, a DC axial fan for servers and data-center electronics. 8300 rpm is the model's most distinctive operating parameter. For design qualification, start with the supplied system interface. Match the exact part number before approving a substitute.

12 60x60x25mm 68 164.4 3.24 8300 46
PF60251B3-10000-A99 | SUNON 12V 1.42W 60x60x25mm 49.3m3/h DC Axial Fan for Data Center Cooling

The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.

12 60x60x25mm 49.3 102.1 1.42 6200 37.5
PF60251B2-10000-A99 | SUNON 12V 1.98W 60x60x25mm 53.5m3/h DC Axial Fan for Data Center Cooling

For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.

12 60x60x25mm 53.5 124.5 1.98 7000 40.7
PF60251B1-10000-A99 | SUNON 12V 2.34W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling

SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.

12 60x60x25mm 61.2 139.5 2.34 7500 41.7
PF40561BX-10000-A9H | SUNON 12V 16.68W 40x40x56mm 53.9m3/h DC Axial Fan for Data Center Cooling

Engineered for servers and data-center electronics, SUNON PF40561BX-10000-A9H is a 12 VDC DC axial fan in a 40 × 40 × 56 mm frame. 936.6 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated selection parameters. Match the exact part number before approving a substitute.

12 40x40x56mm 53.9 936.6 16.68 - 65.9
PF40561B1-10000-A9H | SUNON 12V 10.68W 40x40x56mm 45.7m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.

12 40x40x56mm 45.7 657.6 10.68 - 62.3
PF40281V1-0000-A99 | SUNON 12V 8.88W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling

Equipment designers working with servers and data-center electronics can evaluate SUNON PF40281V1-0000-A99, a DC axial fan rated at 12 VDC and sized 40 × 40 × 28 mm. 17600 rpm is the model's most distinctive operating parameter. The recorded motor input should guide design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 42.3 485.7 8.88 17600 56
PF40281BX-10000-A9H | SUNON 12V 11.4W 40x40x28mm 53.2m3/h 22000rpm DC Axial Fan for New Energy

The PF40281BX-10000-A9H is SUNON's 12 VDC, 40 × 40 × 28 mm DC axial fan option for inverters, energy-storage systems, and charging equipment. 22000 rpm is the model's most distinctive operating parameter. For design qualification, start with the supplied ventilation capacity. Match the exact part number before approving a substitute.

12 40x40x28mm 53.2 777.2 11.4 22000 62
PF40281B4-10000-A9H | SUNON 12V 1.16W 40x40x28mm 21.7m3/h DC Axial Fan for Data Center Cooling

For thermal management in servers and data-center electronics, the PF40281B4-10000-A9H provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 9200 rpm is the model's most distinctive operating parameter. Use the documented equipment fit when planning design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 21.7 149.5 1.16 9200 39.9
PF40281B3-10000-A9H | SUNON 12V 1.74W 40x40x28mm 26.2m3/h DC Axial Fan for Data Center Cooling

SUNON PF40281B3-10000-A9H combines a 40 × 40 × 28 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 11000 rpm is the model's most distinctive operating parameter. Review its suffix definition during design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 26.2 194.3 1.74 11000 43.9
PF40281B2-10000-A9H | SUNON 12V 2.64W 40x40x28mm 30.6m3/h DC Axial Fan for Data Center Cooling

Sized for servers and data-center electronics, SUNON PF40281B2-10000-A9H is a 12 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13000 rpm is the model's most distinctive operating parameter. Treat the catalog specification as a primary input to design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 30.6 288.9 2.64 13000 48.7
PF40281B1-10000-A9H | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF40281B1-10000-A9H serves as a 40 × 40 × 28 mm DC axial fan operating at 12 VDC. 17600 rpm is the model's most distinctive operating parameter. Base design qualification on the stated thermal-duty record. Match the exact part number before approving a substitute.

12 40x40x28mm 42.3 510.6 6.12 17600 56
PF38281BX-10000-A9H | SUNON 12V 6.84W 38x38x28mm 39.1m3/h DC Axial Fan for Data Center Cooling

SUNON configures PF38281BX-10000-A9H as a 38 × 38 × 28 mm DC axial fan for servers and data-center electronics, operating at 12 VDC. 20000 rpm is the model's most distinctive operating parameter. During design qualification, compare the model's performance curve. Match the exact part number before approving a substitute.

12 38x38x28mm 39.1 562.9 6.84 20000 57
PF38281B4-10000-A9H | SUNON 12V 1.14W 38x38x28mm 19.2m3/h DC Axial Fan for Data Center Cooling

The PF38281B4-10000-A9H is SUNON's 12 VDC, 38 × 38 × 28 mm DC axial fan option for servers and data-center electronics. 10000 rpm is the model's most distinctive operating parameter. The recorded mounting size should guide design qualification. Match the exact part number before approving a substitute.

12 38x38x28mm 19.2 154.4 1.14 10000 40.8
PF38281B3-10000-A9H | SUNON 12V 2.16W 38x38x28mm 25.3m3/h DC Axial Fan for Data Center Cooling

For airflow duties across servers and data-center electronics, the PF38281B3-10000-A9H provides a 12 VDC DC axial fan configuration measuring 38 × 38 × 28 mm. 13000 rpm is the model's most distinctive operating parameter. For design qualification, start with the supplied supply requirement. Match the exact part number before approving a substitute.

12 38x38x28mm 25.3 256.6 2.16 13000 47.3
显示
341-360
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
1 2 ... 15 16 17 18 19 20 21 ... 50 51
跳转 页

关于DC粉丝

如何选择合适的DC粉丝

确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。

DC粉丝的典型应用场景与案例

我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

DC粉丝采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持DC粉丝的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。