| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() PF92382B2-10000-A9H | SUNON 24V 11.52W 92x92x38mm 204.2m3/h DC Axial Fan for Data Center Cooling The PF92382B2-10000-A9H is SUNON's 24 VDC, 92 × 92 × 38 mm DC axial fan option for servers and data-center electronics. Up to 204.2 m³/h is its most prominent listed performance figure. During operating-cost analysis, compare the model's cooling specification. Validate mounting and wiring from the model drawing. |
24 | 92x92x38mm | 204.2 | 179.3 | 11.52 | 5800 | 54.7 | |
![]() PF92381BX-10000-A9H | SUNON 12V 50.4W 92x92x38mm 309.9m3/h 12000rpm DC Axial Fan for New Energy Within inverters, energy-storage systems, and charging equipment, PF92381BX-10000-A9H provides a 92 × 92 × 38 mm, 12 VDC DC axial fan configuration. Up to 309.9 m³/h is its most prominent listed performance figure. The recorded duty-point values should guide operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 92x92x38mm | 309.9 | 732.3 | 50.4 | 12000 | 70.2 | |
![]() PF92381B3-10000-A9H | SUNON 12V 5.82W 92x92x38mm 155.8m3/h DC Axial Fan for Data Center Cooling SUNON PF92381B3-10000-A9H combines a 92 × 92 × 38 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 155.8 m³/h is its most prominent listed performance figure. For operating-cost analysis, start with the supplied installation footprint. Validate mounting and wiring from the model drawing. |
12 | 92x92x38mm | 155.8 | 127 | 5.82 | 4700 | 49.5 | |
![]() PF92381B2-10000-A9H | SUNON 12V 11.22W 92x92x38mm 204.2m3/h DC Axial Fan for Data Center Cooling Positioned for servers and data-center electronics, SUNON PF92381B2-10000-A9H is a 12 VDC DC axial fan in a 92 × 92 × 38 mm frame. Up to 204.2 m³/h is its most prominent listed performance figure. Use the documented selection parameters when planning operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 92x92x38mm | 204.2 | 179.3 | 11.22 | 5800 | 54.7 | |
![]() PF92381B1-10000-A9H | SUNON 12V 22.2W 92x92x38mm 234.6m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF92381B1-10000-A9H serves as a 92 × 92 × 38 mm DC axial fan operating at 12 VDC. Up to 234.6 m³/h is its most prominent listed performance figure. Review its rated dataset during operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 92x92x38mm | 234.6 | 485.7 | 22.2 | 9300 | 62.9 | |
![]() PF92252V3-10000-A99 | SUNON 24V 3.03W 92x92x25mm 110.4m3/h DC Axial Fan for Data Center Cooling SUNON PF92252V3-10000-A99 is a 24 VDC DC axial fan in a 92 × 92 × 25 mm format for servers and data-center electronics. Up to 110.4 m³/h is its most prominent listed performance figure. Treat the motor input as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing. |
24 | 92x92x25mm | 110.4 | 62.3 | 3.03 | 3900 | 41.6 | |
![]() PF92252V2-10000-A99 | SUNON 24V 3.48W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling The PF92252V2-10000-A99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Up to 118.9 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated ventilation capacity. Validate mounting and wiring from the model drawing. |
24 | 92x92x25mm | 118.9 | 74.7 | 3.48 | 4200 | 43.7 | |
![]() PF92252V1-10000-A99 | SUNON 24V 5.04W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling For airflow duties across servers and data-center electronics, the PF92252V1-10000-A99 provides a 24 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Up to 127.4 m³/h is its most prominent listed performance figure. During operating-cost analysis, compare the model's equipment fit. Validate mounting and wiring from the model drawing. |
24 | 92x92x25mm | 127.4 | 87.2 | 5.04 | 4500 | 45.5 | |
![]() PF92252B1-10000-A99 | SUNON 24V 4.92W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling SUNON PF92252B1-10000-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Up to 127.4 m³/h is its most prominent listed performance figure. The recorded suffix definition should guide operating-cost analysis. Validate mounting and wiring from the model drawing. |
24 | 92x92x25mm | 127.4 | 87.2 | 4.92 | 4500 | 46.1 | |
![]() PF92251V3-10000-A99 | SUNON 12V 2.76W 92x92x25mm 110.4m3/h DC Axial Fan for Data Center Cooling Built around servers and data-center electronics, SUNON PF92251V3-10000-A99 is a 12 VDC DC axial fan in a 92 × 92 × 25 mm frame. Up to 110.4 m³/h is its most prominent listed performance figure. For operating-cost analysis, start with the supplied catalog specification. Validate mounting and wiring from the model drawing. |
12 | 92x92x25mm | 110.4 | 62.3 | 2.76 | 3900 | 41.6 | |
![]() PF92251V2-10000-A99 | SUNON 12V 3.36W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF92251V2-10000-A99 serves as a 92 × 92 × 25 mm DC axial fan operating at 12 VDC. Up to 118.9 m³/h is its most prominent listed performance figure. Use the documented thermal-duty record when planning operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 92x92x25mm | 118.9 | 74.7 | 3.36 | 4200 | 43.7 | |
![]() PF92251V1-10000-A99 | SUNON 12V 4.44W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON PF92251V1-10000-A99, a DC axial fan rated at 12 VDC and sized 92 × 92 × 25 mm. Up to 127.4 m³/h is its most prominent listed performance figure. Review its performance curve during operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 92x92x25mm | 127.4 | 87.2 | 4.44 | 4500 | 45.5 | |
![]() PF92251B3-10000-A99 | SUNON 12V 2.7W 92x92x25mm 110.4m3/h DC Axial Fan for Data Center Cooling The PF92251B3-10000-A99 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Up to 110.4 m³/h is its most prominent listed performance figure. Treat the mounting size as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 92x92x25mm | 110.4 | 62.3 | 2.7 | 3900 | 41.8 | |
![]() PF92251B2-10000-A99 | SUNON 12V 3.3W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling For ventilation needs in servers and data-center electronics, the PF92251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Up to 118.9 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated supply requirement. Validate mounting and wiring from the model drawing. |
12 | 92x92x25mm | 118.9 | 74.7 | 3.3 | 4200 | 44 | |
![]() PF92251B1-10000-A99 | SUNON 12V 4.32W 92x92x25mm 127.4m3/h DC Axial Fan for Data Center Cooling SUNON PF92251B1-10000-A99 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 127.4 m³/h is its most prominent listed performance figure. During operating-cost analysis, compare the model's static-pressure entry. Validate mounting and wiring from the model drawing. |
12 | 92x92x25mm | 127.4 | 87.2 | 4.32 | 4500 | 46.1 | |
![]() PF80801BX-0000-A9H | SUNON 12V 81.6W 80x80x80mm 257.4m3/h DC Axial Fan for Data Center Cooling Configured for servers and data-center electronics, SUNON PF80801BX-0000-A9H is a 12 VDC DC axial fan in a 80 × 80 × 80 mm frame. 1355 Pa maximum pressure is the standout documented duty-point value. The recorded volume-flow figure should guide operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 80x80x80mm | 257.4 | 1355 | 81.6 | - | 80.4 | |
![]() PF80801BX-000 | SUNON 12V 81.6W 80x80x80mm 257.4m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF80801BX-000 serves as a 80 × 80 × 80 mm DC axial fan operating at 12 VDC. 1355 Pa maximum pressure is the standout documented duty-point value. For operating-cost analysis, start with the supplied sound level. Validate mounting and wiring from the model drawing. |
12 | 80x80x80mm | 257.4 | 1355 | 81.6 | - | 80.4 | |
![]() PF80801B1-0000-A9H | SUNON 12V 42W 80x80x80mm 207.3m3/h DC Axial Fan for Data Center Cooling Specified at 12 VDC, PF80801B1-0000-A9H is a SUNON DC axial fan for servers and data-center electronics in 80 × 80 × 80 mm dimensions. 911.7 Pa maximum pressure is the standout documented duty-point value. Use the documented rotational rating when planning operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 80x80x80mm | 207.3 | 911.7 | 42 | - | 75.1 | |
![]() PF80384BX-0000-A99 | SUNON 48V 33.6W 80x80x38mm 228.2m3/h DC Axial Fan for Data Center Cooling The PF80384BX-0000-A99 is SUNON's 48 VDC, 80 × 80 × 38 mm DC axial fan option for servers and data-center electronics. 834.5 Pa maximum pressure is the standout documented duty-point value. Review its power demand during operating-cost analysis. Validate mounting and wiring from the model drawing. |
48 | 80x80x38mm | 228.2 | 834.5 | 33.6 | 12900 | 67.5 | |
![]() PF80384B1-0000-A99 | SUNON 48V 18.24W 80x80x38mm 179.8m3/h DC Axial Fan for Data Center Cooling Built for servers and data-center electronics, SUNON PF80384B1-0000-A99 uses a 80 × 80 × 38 mm DC axial fan arrangement at 48 VDC. 612.8 Pa maximum pressure is the standout documented duty-point value. Treat the frame geometry as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing. |
48 | 80x80x38mm | 179.8 | 612.8 | 18.24 | 10500 | 62.6 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。