| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() PF80382B3-10000-A9H | SUNON 24V 6.87W 80x80x38mm 126.6m3/h DC Axial Fan for Data Center Cooling SUNON PF80382B3-10000-A9H combines a 80 × 80 × 38 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 142 Pa maximum pressure is the standout documented duty-point value. Base operating-cost analysis on the stated cooling output. Validate mounting and wiring from the model drawing. |
24 | 80x80x38mm | 126.6 | 142 | 6.87 | 5600 | 51.5 | |
![]() PF80382B2-10000-A9H | SUNON 24V 10.23W 80x80x38mm 142.9m3/h DC Axial Fan for Data Center Cooling Engineered for servers and data-center electronics, SUNON PF80382B2-10000-A9H is a 24 VDC DC axial fan in a 80 × 80 × 38 mm frame. 184.3 Pa maximum pressure is the standout documented duty-point value. During operating-cost analysis, compare the model's operating point. Validate mounting and wiring from the model drawing. |
24 | 80x80x38mm | 142.9 | 184.3 | 10.23 | 6400 | 54.5 | |
![]() PF80381BX-10000-A9H | SUNON 12V 48W 80x80x38mm 241.1m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF80381BX-10000-A9H serves as a 80 × 80 × 38 mm DC axial fan operating at 12 VDC. 871.8 Pa maximum pressure is the standout documented duty-point value. The recorded pressure capability should guide operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 80x80x38mm | 241.1 | 871.8 | 48 | 14000 | 69.1 | |
![]() PF80381B3-10000-A9H | SUNON 12V 6.9W 80x80x38mm 126.6m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, PF80381B3-10000-A9H provides a 80 × 80 × 38 mm, 12 VDC DC axial fan configuration. 142 Pa maximum pressure is the standout documented duty-point value. For operating-cost analysis, start with the supplied dimensional envelope. Validate mounting and wiring from the model drawing. |
12 | 80x80x38mm | 126.6 | 142 | 6.9 | 5600 | 51.5 | |
![]() PF80381B2-10000-A9H | SUNON 12V 10.44W 80x80x38mm 142.9m3/h DC Axial Fan for Data Center Cooling The PF80381B2-10000-A9H is SUNON's 12 VDC, 80 × 80 × 38 mm DC axial fan option for servers and data-center electronics. 184.3 Pa maximum pressure is the standout documented duty-point value. Use the documented acoustic value when planning operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 80x80x38mm | 142.9 | 184.3 | 10.44 | 6400 | 54.5 | |
![]() PF80381B1-10000-A9H | SUNON 12V 21.6W 80x80x38mm 193.5m3/h DC Axial Fan for Data Center Cooling For thermal management in servers and data-center electronics, the PF80381B1-10000-A9H provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 667.6 Pa maximum pressure is the standout documented duty-point value. Review its electrical load during operating-cost analysis. Validate mounting and wiring from the model drawing. |
12 | 80x80x38mm | 193.5 | 667.6 | 21.6 | 11200 | 63.4 | |
![]() PF80252V3-10000-A99 | SUNON 24V 2.64W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling SUNON PF80252V3-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Up to 90 m³/h is its most prominent listed performance figure. Treat the speed benchmark as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing. |
24 | 80x80x25mm | 90 | 74.7 | 2.64 | 4200 | 41.5 | |
![]() PF80252V2-10000-A99 | SUNON 24V 3.03W 80x80x25mm 96.8m3/h DC Axial Fan for Data Center Cooling Sized for servers and data-center electronics, SUNON PF80252V2-10000-A99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 96.8 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated airflow profile. Validate mounting and wiring from the model drawing. |
24 | 80x80x25mm | 96.8 | 87.2 | 3.03 | 4500 | 43.1 | |
![]() PF80252V1-10000-A99 | SUNON 24V 4.32W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF80252V1-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. During installation review, compare the model's application data. Obtain the applicable curve before final duty-point approval. |
24 | 80x80x25mm | 101.9 | 102.1 | 4.32 | 4800 | 44.7 | |
![]() PF80252B3-10000-A99 | SUNON 24V 2.4W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling The 80 × 80 × 25 mm PF80252B3-10000-A99 brings 24 VDC DC axial fan cooling to servers and data-center electronics. Up to 90 m³/h is its most prominent listed performance figure. The recorded technical profile should guide installation review. Obtain the applicable curve before final duty-point approval. |
24 | 80x80x25mm | 90 | 74.7 | 2.4 | 4200 | 42.5 | |
![]() PF80252B1-10000-A99 | SUNON 24V 3.72W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling The PF80252B1-10000-A99 is SUNON's 24 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied model record. Obtain the applicable curve before final duty-point approval. |
24 | 80x80x25mm | 101.9 | 102.1 | 3.72 | 4800 | 45.5 | |
![]() PF80251V3-10000-A99 | SUNON 12V 2.4W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling PF80251V3-10000-A99 addresses servers and data-center electronics through a 12 VDC DC axial fan platform measuring 80 × 80 × 25 mm. Up to 90 m³/h is its most prominent listed performance figure. Use the documented product configuration when planning installation review. Obtain the applicable curve before final duty-point approval. |
12 | 80x80x25mm | 90 | 74.7 | 2.4 | 4200 | 41.5 | |
![]() PF80251V2-10000-A99 | SUNON 12V 2.88W 80x80x25mm 96.8m3/h DC Axial Fan for Data Center Cooling SUNON PF80251V2-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 96.8 m³/h is its most prominent listed performance figure. Review its system interface during installation review. Obtain the applicable curve before final duty-point approval. |
12 | 80x80x25mm | 96.8 | 87.2 | 2.88 | 4500 | 43.1 | |
![]() PF80251V1-10000-A99 | SUNON 12V 3.72W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling Designed for servers and data-center electronics, SUNON PF80251V1-10000-A99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. 102.1 Pa maximum pressure is the standout documented duty-point value. Treat the cooling specification as a primary input to installation review. Obtain the applicable curve before final duty-point approval. |
12 | 80x80x25mm | 101.9 | 102.1 | 3.72 | 4800 | 44.7 | |
![]() PF80251B3-10000-A99 | SUNON 12V 2.34W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON PF80251B3-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 12 VDC. Up to 90 m³/h is its most prominent listed performance figure. Base installation review on the stated duty-point values. Obtain the applicable curve before final duty-point approval. |
12 | 80x80x25mm | 90 | 74.7 | 2.34 | 4200 | 42.5 | |
![]() PF80251B2-10000-A99 | SUNON 12V 3.06W 80x80x25mm 96.8m3/h DC Axial Fan for Data Center Cooling The 12 VDC SUNON PF80251B2-10000-A99 is a DC axial fan sized 80 × 80 × 25 mm for servers and data-center electronics. Up to 96.8 m³/h is its most prominent listed performance figure. During installation review, compare the model's installation footprint. Obtain the applicable curve before final duty-point approval. |
12 | 80x80x25mm | 96.8 | 87.2 | 3.06 | 4500 | 44 | |
![]() PF80251B1-10000-A99 | SUNON 12V 3.54W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling The PF80251B1-10000-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. The recorded selection parameters should guide installation review. Obtain the applicable curve before final duty-point approval. |
12 | 80x80x25mm | 101.9 | 102.1 | 3.54 | 4800 | 45.5 | |
![]() PF75302B3-1B000-A99 | SUNON 24V 1.13W 75x75x30mm DC Centrifugal Blower for Data Center Cooling For ventilation needs in servers and data-center electronics, the PF75302B3-1B000-A99 provides a 24 VDC DC blower configuration measuring 75 × 75 × 30 mm. Its 2400 rpm rating defines a lower-speed operating point. For installation review, start with the supplied rated dataset. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 18.3 | 59.8 | 1.13 | 2400 | 32.9 | |
![]() PF75302B2-1B000-A99 | SUNON 24V 1.92W 75x75x30mm DC Centrifugal Blower for Data Center Cooling SUNON PF75302B2-1B000-A99 combines a 75 × 75 × 30 mm DC blower platform with a 24 VDC rating for servers and data-center electronics. Its 3000 rpm rating defines a lower-speed operating point. Use the documented motor input when planning installation review. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 23.4 | 107.1 | 1.92 | 3000 | 38.6 | |
![]() PF75302B1-1B000-A99 | SUNON 24V 2.76W 75x75x30mm DC Centrifugal Blower for Data Center Cooling Used in servers and data-center electronics, SUNON PF75302B1-1B000-A99 is a 24 VDC DC blower in a 75 × 75 × 30 mm frame. 142 Pa maximum pressure is the standout documented duty-point value. Review its ventilation capacity during installation review. Obtain the applicable curve before final duty-point approval. |
24 | 75x75x30mm | 26.3 | 142 | 2.76 | 3400 | 42 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。