获取报价
首页 > 产品 > 按品牌 > SUNON > DC粉丝

DC粉丝

按类型

按行业

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

库存选项

环保选项

资料

排除

1,011 个结果

已选条件

显示
301-320
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
PF80382B3-10000-A9H | SUNON 24V 6.87W 80x80x38mm 126.6m3/h DC Axial Fan for Data Center Cooling

SUNON PF80382B3-10000-A9H combines a 80 × 80 × 38 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 142 Pa maximum pressure is the standout documented duty-point value. Base operating-cost analysis on the stated cooling output. Validate mounting and wiring from the model drawing.

24 80x80x38mm 126.6 142 6.87 5600 51.5
PF80382B2-10000-A9H | SUNON 24V 10.23W 80x80x38mm 142.9m3/h DC Axial Fan for Data Center Cooling

Engineered for servers and data-center electronics, SUNON PF80382B2-10000-A9H is a 24 VDC DC axial fan in a 80 × 80 × 38 mm frame. 184.3 Pa maximum pressure is the standout documented duty-point value. During operating-cost analysis, compare the model's operating point. Validate mounting and wiring from the model drawing.

24 80x80x38mm 142.9 184.3 10.23 6400 54.5
PF80381BX-10000-A9H | SUNON 12V 48W 80x80x38mm 241.1m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF80381BX-10000-A9H serves as a 80 × 80 × 38 mm DC axial fan operating at 12 VDC. 871.8 Pa maximum pressure is the standout documented duty-point value. The recorded pressure capability should guide operating-cost analysis. Validate mounting and wiring from the model drawing.

12 80x80x38mm 241.1 871.8 48 14000 69.1
PF80381B3-10000-A9H | SUNON 12V 6.9W 80x80x38mm 126.6m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, PF80381B3-10000-A9H provides a 80 × 80 × 38 mm, 12 VDC DC axial fan configuration. 142 Pa maximum pressure is the standout documented duty-point value. For operating-cost analysis, start with the supplied dimensional envelope. Validate mounting and wiring from the model drawing.

12 80x80x38mm 126.6 142 6.9 5600 51.5
PF80381B2-10000-A9H | SUNON 12V 10.44W 80x80x38mm 142.9m3/h DC Axial Fan for Data Center Cooling

The PF80381B2-10000-A9H is SUNON's 12 VDC, 80 × 80 × 38 mm DC axial fan option for servers and data-center electronics. 184.3 Pa maximum pressure is the standout documented duty-point value. Use the documented acoustic value when planning operating-cost analysis. Validate mounting and wiring from the model drawing.

12 80x80x38mm 142.9 184.3 10.44 6400 54.5
PF80381B1-10000-A9H | SUNON 12V 21.6W 80x80x38mm 193.5m3/h DC Axial Fan for Data Center Cooling

For thermal management in servers and data-center electronics, the PF80381B1-10000-A9H provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 667.6 Pa maximum pressure is the standout documented duty-point value. Review its electrical load during operating-cost analysis. Validate mounting and wiring from the model drawing.

12 80x80x38mm 193.5 667.6 21.6 11200 63.4
PF80252V3-10000-A99 | SUNON 24V 2.64W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling

SUNON PF80252V3-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Up to 90 m³/h is its most prominent listed performance figure. Treat the speed benchmark as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing.

24 80x80x25mm 90 74.7 2.64 4200 41.5
PF80252V2-10000-A99 | SUNON 24V 3.03W 80x80x25mm 96.8m3/h DC Axial Fan for Data Center Cooling

Sized for servers and data-center electronics, SUNON PF80252V2-10000-A99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 96.8 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated airflow profile. Validate mounting and wiring from the model drawing.

24 80x80x25mm 96.8 87.2 3.03 4500 43.1
PF80252V1-10000-A99 | SUNON 24V 4.32W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF80252V1-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. 102.1 Pa maximum pressure is the standout documented duty-point value. During installation review, compare the model's application data. Obtain the applicable curve before final duty-point approval.

24 80x80x25mm 101.9 102.1 4.32 4800 44.7
PF80252B3-10000-A99 | SUNON 24V 2.4W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling

The 80 × 80 × 25 mm PF80252B3-10000-A99 brings 24 VDC DC axial fan cooling to servers and data-center electronics. Up to 90 m³/h is its most prominent listed performance figure. The recorded technical profile should guide installation review. Obtain the applicable curve before final duty-point approval.

24 80x80x25mm 90 74.7 2.4 4200 42.5
PF80252B1-10000-A99 | SUNON 24V 3.72W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling

The PF80252B1-10000-A99 is SUNON's 24 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. For installation review, start with the supplied model record. Obtain the applicable curve before final duty-point approval.

24 80x80x25mm 101.9 102.1 3.72 4800 45.5
PF80251V3-10000-A99 | SUNON 12V 2.4W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling

PF80251V3-10000-A99 addresses servers and data-center electronics through a 12 VDC DC axial fan platform measuring 80 × 80 × 25 mm. Up to 90 m³/h is its most prominent listed performance figure. Use the documented product configuration when planning installation review. Obtain the applicable curve before final duty-point approval.

12 80x80x25mm 90 74.7 2.4 4200 41.5
PF80251V2-10000-A99 | SUNON 12V 2.88W 80x80x25mm 96.8m3/h DC Axial Fan for Data Center Cooling

SUNON PF80251V2-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 96.8 m³/h is its most prominent listed performance figure. Review its system interface during installation review. Obtain the applicable curve before final duty-point approval.

12 80x80x25mm 96.8 87.2 2.88 4500 43.1
PF80251V1-10000-A99 | SUNON 12V 3.72W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling

Designed for servers and data-center electronics, SUNON PF80251V1-10000-A99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. 102.1 Pa maximum pressure is the standout documented duty-point value. Treat the cooling specification as a primary input to installation review. Obtain the applicable curve before final duty-point approval.

12 80x80x25mm 101.9 102.1 3.72 4800 44.7
PF80251B3-10000-A99 | SUNON 12V 2.34W 80x80x25mm 90m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF80251B3-10000-A99 serves as a 80 × 80 × 25 mm DC axial fan operating at 12 VDC. Up to 90 m³/h is its most prominent listed performance figure. Base installation review on the stated duty-point values. Obtain the applicable curve before final duty-point approval.

12 80x80x25mm 90 74.7 2.34 4200 42.5
PF80251B2-10000-A99 | SUNON 12V 3.06W 80x80x25mm 96.8m3/h DC Axial Fan for Data Center Cooling

The 12 VDC SUNON PF80251B2-10000-A99 is a DC axial fan sized 80 × 80 × 25 mm for servers and data-center electronics. Up to 96.8 m³/h is its most prominent listed performance figure. During installation review, compare the model's installation footprint. Obtain the applicable curve before final duty-point approval.

12 80x80x25mm 96.8 87.2 3.06 4500 44
PF80251B1-10000-A99 | SUNON 12V 3.54W 80x80x25mm 101.9m3/h DC Axial Fan for Data Center Cooling

The PF80251B1-10000-A99 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. The recorded selection parameters should guide installation review. Obtain the applicable curve before final duty-point approval.

12 80x80x25mm 101.9 102.1 3.54 4800 45.5
PF75302B3-1B000-A99 | SUNON 24V 1.13W 75x75x30mm DC Centrifugal Blower for Data Center Cooling

For ventilation needs in servers and data-center electronics, the PF75302B3-1B000-A99 provides a 24 VDC DC blower configuration measuring 75 × 75 × 30 mm. Its 2400 rpm rating defines a lower-speed operating point. For installation review, start with the supplied rated dataset. Obtain the applicable curve before final duty-point approval.

24 75x75x30mm 18.3 59.8 1.13 2400 32.9
PF75302B2-1B000-A99 | SUNON 24V 1.92W 75x75x30mm DC Centrifugal Blower for Data Center Cooling

SUNON PF75302B2-1B000-A99 combines a 75 × 75 × 30 mm DC blower platform with a 24 VDC rating for servers and data-center electronics. Its 3000 rpm rating defines a lower-speed operating point. Use the documented motor input when planning installation review. Obtain the applicable curve before final duty-point approval.

24 75x75x30mm 23.4 107.1 1.92 3000 38.6
PF75302B1-1B000-A99 | SUNON 24V 2.76W 75x75x30mm DC Centrifugal Blower for Data Center Cooling

Used in servers and data-center electronics, SUNON PF75302B1-1B000-A99 is a 24 VDC DC blower in a 75 × 75 × 30 mm frame. 142 Pa maximum pressure is the standout documented duty-point value. Review its ventilation capacity during installation review. Obtain the applicable curve before final duty-point approval.

24 75x75x30mm 26.3 142 2.76 3400 42
显示
301-320
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
1 2 ... 13 14 15 16 17 18 19 ... 50 51
跳转 页

关于DC粉丝

如何选择合适的DC粉丝

确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。

DC粉丝的典型应用场景与案例

我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

DC粉丝采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持DC粉丝的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。