| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() EE80252BX-000U-A99 | SUNON 24V 1.9W 80x80x25mm 76.5m3/h DC Axial Fan for Industrial Cooling For airflow duties across telecom cabinets, base stations, and network equipment, the EE80252BX-000U-A99 provides a 24 VDC DC blower configuration measuring 80 × 80 × 25 mm. Its 3600 rpm rating defines a lower-speed operating point. The recorded duty-point values should guide wiring review. Confirm environmental protection for the ordered version. |
24 | 80x80x25mm | 76.5 | 57.3 | 1.9 | 3600 | 38 | |
![]() MF80201V1-C02C-S99 | SUNON 12V 3.24W 80x80x20mm DC Axial Fan for Telecommunications SUNON MF80201V1-C02C-S99 combines a 80 × 80 × 20 mm DC blower platform with a 12 VDC rating for telecom cabinets and network equipment. 3.24 W input is the defining electrical load in the supplied data. For wiring review, start with the supplied installation footprint. Confirm environmental protection for the ordered version. |
12 | 80*80*20 | - | - | 3.24 | - | - | |
![]() EEC0251B1-000U-A99 | SUNON 12V 5.4W 120x120x25mm 183.8m3/h DC Axial Fan for Industrial Cooling Designed for telecom cabinets, base stations, and network equipment, SUNON EEC0251B1-000U-A99 is a 12 VDC DC axial fan in a 120 × 120 × 25 mm frame. Up to 183.8 m³/h is its most prominent listed performance figure. Use the documented selection parameters when planning wiring review. Confirm environmental protection for the ordered version. |
12 | 120x120x25 | 183.8 | 69.7 | 5.4 | 3100 | 44.5 | |
![]() MF50151VX-B00U-G99 | SUNON 12V 2.04W 50x50x15mm 9.2m3/h DC Axial Fan for Telecommunications Within telecom cabinets and network equipment, SUNON MF50151VX-B00U-G99 serves as a 50 × 50 × 15 mm DC blower operating at 12 VDC. Its 9.2 m³/h airflow rating suits the stated equipment-cooling role. Review its rated dataset during wiring review. Confirm environmental protection for the ordered version. |
12 | 50x50x15mm | 9.2 | 241.6 | 2.04 | 6000 | 42.2 | |
![]() PE60251B1-000U-G99 | SUNON 12V 3.57W 60x60x25mm 61.2m3/h DC Axial Fan for Industrial Cooling SUNON PE60251B1-000U-G99 is a 12 VDC DC blower in a 60 × 60 × 25 mm format for industrial electronics and equipment cooling. 134.5 Pa maximum pressure is the standout documented duty-point value. Treat the motor input as a primary input to wiring review. Confirm environmental protection for the ordered version. |
12 | 60x60x25mm | 61.2 | 134.5 | 3.57 | 6900 | 44 | |
![]() EF60252S1-1000U-A99 | SUNON 24V 1.2W 60x60x25mm 39.9m3/h DC Axial Fan for Industrial Cooling The EF60252S1-1000U-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for telecom cabinets, base stations, and network equipment. A listed noise value of 27 dB is the model's key differentiator. Base wiring review on the stated ventilation capacity. Confirm environmental protection for the ordered version. |
24 | 60x60x25 | 39.9 | 52.3 | 1.2 | 4500 | 27 | |
![]() PF97332B2-L03C-S99 | SUNON 24V 9.12W 97x33mm DC Axial Fan for Industrial Cooling For ventilation needs in servers and data-center electronics, the PF97332B2-L03C-S99 provides a 24 VDC DC blower configuration measuring 97 × 33 mm. 9.12 W input is the defining electrical load in the supplied data. During wiring review, compare the model's equipment fit. Confirm environmental protection for the ordered version. |
24 | 97*33 | - | - | 9.12 | - | - | |
![]() MF50101V1-1000U-G99 | SUNON 12V 0.84W 50x50x10mm 5800rpm DC Axial Fan for New Energy SUNON MF50101V1-1000U-G99 combines a 50 × 50 × 10 mm DC axial fan platform with a 12 VDC rating for inverters, energy-storage systems, and charging equipment. A listed input of 0.84 W is the model's notable electrical characteristic. The recorded suffix definition should guide wiring review. Confirm environmental protection for the ordered version. |
12 | 50x50x10mm | - | 37.4 | 0.84 | 5800 | - | |
![]() PF70201V1-000U-A99 | SUNON 12V 3.42W 70x70x20mm 73.1m3/h DC Axial Fan for Industrial Cooling Used in servers and data-center electronics, SUNON PF70201V1-000U-A99 is a 12 VDC DC blower in a 70 × 70 × 20 mm frame. Up to 73.1 m³/h is its most prominent listed performance figure. For wiring review, start with the supplied catalog specification. Confirm environmental protection for the ordered version. |
12 | 70x70x20mm | 73.1 | 69.7 | 3.42 | 4600 | 41.5 | |
![]() PF80251B1-000U-G99 | SUNON 12V 4.1W 80x80x25mm 101.9m3/h DC Axial Fan for Industrial Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON PF80251B1-000U-G99, a DC axial fan rated at 12 VDC and sized 80 × 80 × 25 mm. 102.1 Pa maximum pressure is the standout documented duty-point value. Review its performance curve during wiring review. Confirm environmental protection for the ordered version. |
12 | 80x80x25mm | 101.9 | 102.1 | 4.1 | 4800 | 47.5 | |
![]() PF92251B1-000U-G99 | SUNON 12V 4.7W 92x92x25mm 127.4m3/h DC Axial Fan for Industrial Cooling The PF92251B1-000U-G99 is SUNON's 12 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Up to 127.4 m³/h is its most prominent listed performance figure. Treat the mounting size as a primary input to wiring review. Confirm environmental protection for the ordered version. |
12 | 92x92x25mm | 127.4 | 87.2 | 4.7 | 4500 | 47 | |
![]() EEC0381B1-000U-G99 | SUNON 12V 10W 120x120x38mm 234.09m3/h DC Axial Fan for Industrial Cooling The 12 VDC SUNON EEC0381B1-000U-G99 is a DC blower sized 120 × 120 × 38 mm for telecom cabinets, base stations, and network equipment. Up to 234.09 m³/h is its most prominent listed performance figure. Base wiring review on the stated supply requirement. Confirm environmental protection for the ordered version. |
12 | 120x120x38mm | 234.09 | 89.6 | 10 | 3100 | 48 | |
![]() MF60101V1-1000U-G99 | SUNON 12V 1.3W 60x60x10mm 27.7m3/h DC Axial Fan for Telecommunications SUNON MF60101V1-1000U-G99 combines a 60 × 60 × 10 mm DC axial fan platform with a 12VDC VDC rating for telecom cabinets and network equipment. 29.9 Pa maximum pressure is the standout documented duty-point value. During wiring review, compare the model's static-pressure entry. Confirm environmental protection for the ordered version. |
12VDC | 60x60x10 | 27.7 | 29.9 | 1.3 | 4000 | 28.5 | |
![]() PF80252B2-1D03U-S99 | SUNON 24V 3.24W 80x80x25mm 96.8m3/h DC Axial Fan for Industrial Cooling Applied in servers and data-center electronics, SUNON PF80252B2-1D03U-S99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 96.8 m³/h is its most prominent listed performance figure. The recorded volume-flow figure should guide wiring review. Confirm environmental protection for the ordered version. |
24 | 80x80x25mm | 96.8 | 87.2 | 3.24 | 4500 | 44 | |
![]() EE60252B1-000U-A99 | SUNON 24V 1.68W 60x60x25mm 39.9m3/h DC Axial Fan for Industrial Cooling Within telecom cabinets, base stations, and network equipment, SUNON EE60252B1-000U-A99 serves as a 60 × 60 × 25 mm DC blower operating at 24 VDC. Its 39.9 m³/h airflow rating suits the stated equipment-cooling role. For wiring review, start with the supplied sound level. Confirm environmental protection for the ordered version. |
24 | 60x60x25mm | 39.9 | 52.3 | 1.68 | 4500 | 34.5 | |
![]() HA92251V4-1000U-A99 | SUNON 12V 0.54W 92x92x25mm 47.7m3/h DC Axial Fan for Industrial Cooling Specified at 12 VDC, HA92251V4-1000U-A99 is a SUNON DC axial fan for telecom cabinets, base stations, and network equipment in 92 × 92 × 25 mm dimensions. Its 1700 rpm rating defines a lower-speed operating point. Use the documented rotational rating when planning wiring review. Confirm environmental protection for the ordered version. |
12 | 92x92x25 | 47.7 | 12.4 | 0.54 | 1700 | 17.7 | |
![]() MF60251V1-1Q030-S99 | SUNON 12V 0.9W 60x60x25mm 39.9m3/h DC Axial Fan for Telecommunications The MF60251V1-1Q030-S99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for telecom cabinets and network equipment. A listed noise value of 27 dB is the model's key differentiator. Review its power demand during wiring review. Confirm environmental protection for the ordered version. |
12 | 60x60x25mm | 39.9 | 52.3 | 0.9 | 4500 | 27 | |
![]() EF80152B1-EE070-S99 | SUNON 24V 2.16W 80x80x15mm DC Axial Fan for Industrial Cooling Built for telecom cabinets, base stations, and network equipment, SUNON EF80152B1-EE070-S99 uses a 80 × 80 × 15 mm DC blower arrangement at 24 VDC. 2.16 W input is the defining electrical load in the supplied data. Treat the frame geometry as a primary input to wiring review. Confirm environmental protection for the ordered version. |
24 | 80*80*15 | - | - | 2.16 | - | - | |
![]() MF80201V1-C020-Q99 | SUNON 12V 3.24W 80x80x20mm DC Axial Fan for Telecommunications SUNON MF80201V1-C020-Q99 combines a 80 × 80 × 20 mm DC blower platform with a 12 VDC rating for telecom cabinets and network equipment. 3.24 W input is the defining electrical load in the supplied data. Base wiring review on the stated cooling output. Confirm environmental protection for the ordered version. |
12 | 80*80*20 | - | - | 3.24 | - | - | |
![]() PE92252B1-000U-G99 | SUNON 24V 5.28W 92x92x25mm 127.4m3/h DC Axial Fan for Industrial Cooling Positioned for industrial electronics and equipment cooling, SUNON PE92252B1-000U-G99 is a 24 VDC DC blower in a 92 × 92 × 25 mm frame. Up to 127.4 m³/h is its most prominent listed performance figure. During wiring review, compare the model's operating point. Confirm environmental protection for the ordered version. |
24 | 92x92x25mm | 127.4 | 87.2 | 5.28 | 4500 | 47 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。