| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9HVA0312P3K001 | Sanyo Denki 12VDC 25.2W DC Axial Fan for AI servers and high-density equipment cooling Within AI servers and high-density electronics, 9HVA0312P3K001 provides a 38 × 38 × 28 mm, 12 VDC DC axial fan configuration. Ultra-high static-pressure capability is the representative series characteristic. 38500 rpm is the model's most prominent operating value. Check spares strategy planning frame geometry. Focus: spares strategy planning. |
12 | 38*38*28 mm | 54.6 | 2100 | 25.2 | 38500 | 69 | |
![]() 9GA0512P7H001 | Sanyo Denki 12VDC 0.6W DC Axial Fan for UPS, server and telecom equipment cooling Engineered for servers, UPS systems, and telecom equipment, Sanyo Denki 9GA0512P7H001 is a 12 VDC DC axial fan in a 52 × 52 × 15 mm frame. A listed input of 0.6 W is the notable efficiency-related parameter. Long-life series construction is the main characteristic stated in the supplied reference. Focus: spares strategy planning cooling output. |
12 | 52*52*15 mm | 16.5 | 27.5 | 0.6 | 4300 | 22 | |
![]() 9WL0624P4S001 | Sanyo Denki 24VDC 8.16W DC Axial Fan for solar inverter and energy storage cooling Sanyo Denki 9WL0624P4S001 is a 24 VDC DC axial fan in a 60 × 60 × 25 mm format for outdoor equipment and photovoltaic inverters. Its oil-resistant fan design and IP68 listing is the defining supplied feature. 11000 rpm is the model's most prominent operating value. Check spares strategy planning operating point. Focus: spares strategy planning. |
24 | 60*60*25 | 83.98 | 299.9 | 8.16 | 11000 | 53 | |
![]() 9WL0612P4S001 | Sanyo Denki 12VDC 8.04W DC Axial Fan for solar inverter and energy storage cooling For thermal management in outdoor equipment and photovoltaic inverters, the 9WL0612P4S001 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 11000 rpm is the model's most prominent operating value. For mounting verification, start with the supplied frame geometry. Confirm control inputs against the complete ordering code. |
12 | 60*60*25 | 84 | 300 | 8.04 | 11000 | 53 | |
![]() 9RA0812P4G001 | Sanyo Denki 12VDC 2.64W DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 9RA0812P4G001 combines 12 VDC operation with a 80 × 80 × 25 mm DC axial fan design. Series focus: high airflow and pressure. A listed input of 2.64 W is the notable efficiency-related parameter. Check spares strategy planning dimensional envelope. Focus: spares strategy planning dimensional envelope. |
12 | 80*80*25 mm | 84 | 83 | 2.64 | 5000 | 37 | |
![]() 9GA0824P4J0011 | Sanyo Denki 24VDC 6.72W DC Axial Fan for UPS, server and telecom equipment cooling The 24 VDC Sanyo Denki 9GA0824P4J0011 is a DC axial fan sized 80 × 80 × 25 mm for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 7400 rpm is the model's most prominent operating value. Check spares strategy planning acoustic value. |
24 | 80*80*25 mm | 124.2 | 177.6 | 6.72 | 7400 | 48 | |
![]() 9G1212E1D01 | Sanyo Denki 12VDC 7.32W DC Axial Fan for UPS, server and telecom equipment cooling The 9G1212E1D01 is a Sanyo Denki 12 VDC, 119 × 119 × 38 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its system interface during mounting verification. Validate mounting and wiring from the model drawing. Focus: spares strategy planning electrical load. |
12 | 119*119*38 | 198 | 100 | 7.32 | 3100 | 46 | |
![]() 9GA0624P6G001 | Sanyo Denki 24VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0624P6G001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 60 × 60 × 20 mm dimensions. 6850 rpm is the model's most prominent operating value. Review its supply requirement during enclosure sizing. Check the full suffix before confirming connector details. Focus: spares strategy planning. |
24 | 60*60*20 | 52.87 | 124.5 | 2.88 | 6850 | 43 | |
![]() 9S0612P4H17 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling The 9S0612P4H17 is a Sanyo Denki 12 VDC, 60 × 60 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its motor input during duty-point matching. Obtain the applicable curve before final duty-point approval. Focus: spares strategy planning airflow profile. |
12 | 60*60*25 | - | - | - | - | - | |
![]() 9GV1248P1J10 | Sanyo Denki 48VDC DC Axial Fan for automation and control cabinet cooling Sanyo Denki configures 9GV1248P1J10 for industrial controls, power cabinets, and energy systems as a 48 VDC DC axial fan with 120 × 120 × 38 mm dimensions. The 120 × 120 × 38 mm format is the primary stated selection detail. During maintenance preparation, compare the model's equipment fit. Validate mounting and wiring from the model drawing. |
48 | 120*120*38 | - | - | - | - | - | |
![]() 9GA0812H7001 | Sanyo Denki 12VDC 1.08W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0812H7001 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 80 × 80 × 15 mm dimensions. A listed input of 1.08 W is the notable efficiency-related parameter. For duty-point matching, start with the supplied suffix definition. Match the exact part number before approving a substitute. |
12 | 80*80*15 mm | 53.4 | 32.6 | 1.08 | 3800 | 29 | |
![]() 9G1224E4D01 | Sanyo Denki 24VDC 8.88W DC Axial Fan for UPS, server and telecom equipment cooling A 119 × 119 × 25 mm frame and 24 VDC rating define 9G1224E4D01, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 193.2 m³/h is the standout performance value. Check selection criteria review duty-point values. Focus: selection criteria review duty-point values. |
24 | 119*119*25 | 193.2 | 98.1 | 8.88 | 3650 | 48 | |
![]() 9GA0412P6H001 | Sanyo Denki 12VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9GA0412P6H001 combines a 40 × 40 × 20 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The 19.89 m³/h airflow figure supports its stated equipment-cooling role. Focus: selection criteria review. |
12 | 40*40*20 | 19.89 | 191.8 | 1.68 | 12400 | 40 | |
![]() 9G0624G101 | Sanyo Denki 24VDC 20.4W DC Axial Fan for UPS, server and telecom equipment cooling The 24 VDC Sanyo Denki 9G0624G101 is a DC axial fan sized 60 × 60 × 38 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 435.2 Pa maximum pressure is the most distinctive duty-point parameter. Check selection criteria review selection parameters. Focus: selection criteria review selection parameters. |
24 | 60*60*38 | 109.2 | 435.2 | 20.4 | 11800 | 58 | |
![]() 9GA0612P7H01 | Sanyo Denki 12VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling Configured for servers, UPS systems, and telecom equipment, Sanyo Denki 9GA0612P7H01 is a 12 VDC DC axial fan in a 60 × 60 × 15 mm frame. A listed input of 1.2 W is the notable efficiency-related parameter. Long-life series construction is the main characteristic stated in the supplied reference. Focus: selection criteria review rated dataset. |
12 | 60*60*15 mm | 33.6 | 55.6 | 1.2 | 4900 | 34 | |
![]() 109R0812G402 | Sanyo Denki 12VDC 4.44W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109R0812G402 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 80.4 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: selection criteria review motor input. |
12 | 80*80*25 | 88.8 | 80.4 | 4.44 | 4500 | 40 | |
![]() 109R0612H478 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling 109R0612H478 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 60 × 60 × 25 mm. High airflow is highlighted together with a high-static-pressure design. The 60 × 60 × 25 mm format is the primary stated selection detail. Check selection criteria review ventilation capacity. |
12 | 60*60*25 | - | - | - | - | - | |
![]() 9GA1224G4D001 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling The 9GA1224G4D001 is a Sanyo Denki 24 VDC, 120 × 120 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. The recorded airflow profile should guide compatibility checking. Verify the exact bearing and signal options in the datasheet. |
24 | 120*120*25 | - | - | - | - | - | |
![]() 9RA1212P4G0011 | Sanyo Denki 12VDC 6.6W DC Axial Fan for UPS, server and telecom equipment cooling 9RA1212P4G0011 serves servers, UPS systems, and telecom equipment as a 120 × 120 × 25 mm DC axial fan rated at 12 VDC. Series focus: high airflow and pressure. Its listed airflow of 220.8 m³/h is the standout performance value. Check selection criteria review suffix definition. Focus: selection criteria review suffix definition. |
12 | 120*120*25 mm | 220.8 | 120 | 6.6 | 4500 | 47 | |
![]() 9A0824H401 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9A0824H401 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 25 mm dimensions. 35.3 Pa maximum pressure is the most distinctive duty-point parameter. The recorded electrical load should guide cabinet ventilation planning. Verify the exact bearing and signal options in the datasheet. |
24 | 80*80*25 | 62 | 35.3 | 1.68 | 2900 | 29 |
确定三艾斯直流风扇最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 540 件产品可供选购。
我们销售工程师的日常工作围绕三艾斯直流风扇展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 三洋 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。