9WL0412P3J001 | Sanyo Denki 12VDC 6.24W DC Axial Fan for solar inverter and energy storage cooling

The 40 × 40 × 28 mm Sanyo Denki 9WL0412P3J001 brings 12 VDC DC axial fan cooling to outdoor equipment and photovoltaic inverters. Its oil-resistant fan design and IP68 listing is the defining supplied feature. Base airflow-path design on the stated rated dataset. Match the exact part number before approving a substitute.

12 40*40*28 38 400 6.24 17500 51
109P0412G3013 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling

A 40 × 40 × 28 mm frame and 12 VDC rating define 109P0412G3013, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The 25.2 m³/h airflow figure supports its stated equipment-cooling role. Check selection criteria review performance curve. Focus: selection criteria review performance curve.

12 40*40*28 25.2 179 3.72 11500 42
109R0612G401 | Sanyo Denki 12VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling

The 109R0612G401 is a Sanyo Denki 12 VDC, 60 × 60 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. During equipment integration, compare the model's mounting size. Match the exact part number before approving a substitute. Focus: selection criteria review mounting size.

12 60*60*25 47 87.3 2.88 5600 39
109E5724C510 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109E5724C510 combines a 172 × 150 × 51 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 172 × 150 × 51 mm format is the primary stated selection detail. Selection focus: selection criteria review supply requirement.

24 172*150*51 - - - - -
9GA0424P3G001 | Sanyo Denki 24VDC 5.28W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9GA0424P3G001 provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 16500 rpm is the model's most prominent operating value. The recorded duty-point values should guide replacement evaluation. Match the exact part number before approving a substitute.

24 40*40*28 37 450 5.28 16500 53
9GA0412P3J01 | Sanyo Denki 12VDC 5.88W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9GA0412P3J01 combines a 40 × 40 × 28 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. 18000 rpm is the model's most prominent operating value. Focus: selection criteria review volume-flow figure.

12 40*40*28 40 535 5.88 18000 54
9S0912L402 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling

Within servers, UPS systems, and telecom equipment, 9S0912L402 provides a 92 × 92 × 25 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed noise figure of 17 dB is the key differentiating parameter. Check selection criteria review sound level. Focus: selection criteria review.

12 92*92*25 49.2 13.2 - 1750 17
9GA0824P4H001 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9GA0824P4H001 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 2.4 W is the notable efficiency-related parameter. Focus: selection criteria review.

24 80*80*25 88 87.7 2.4 5200 37
9A0812S402 | Sanyo Denki 12VDC 2.16W DC Axial Fan for UPS, server and telecom equipment cooling

9A0812S402 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 80 × 80 × 25 mm. High airflow is highlighted together with a high-static-pressure design. A listed input of 2.16 W is the notable efficiency-related parameter. Check selection criteria review power demand.

12 80*80*25 71.4 48.1 2.16 3400 34
9BMB12P2G01 | Sanyo Denki 12VDC 21.6W DC Centrifugal Blower for medical equipment cooling

For medical equipment cooling, 9BMB12P2G01 combines 12 VDC operation with a 97 × 97 × 33 mm DC blower design. Series options require suffix verification. 760 Pa maximum pressure is the most distinctive duty-point parameter. Check selection criteria review frame geometry. Focus: selection criteria review frame geometry.

12 97*97*33 mm 80.4 760 21.6 5750 61
9HV0948P1G001 | Sanyo Denki 48VDC 57.6W DC Axial Fan for AI servers and high-density equipment cooling

The 9HV0948P1G001 is a Sanyo Denki 48 VDC, 92 × 92 × 38 mm DC axial fan for AI servers and high-density electronics. Ultra-high static-pressure capability is the representative series characteristic. Use the documented motor input when planning acoustic assessment. Validate mounting and wiring from the model drawing.

48 92*92*38 306 1100 57.6 14900 72
109R0812G401 | Sanyo Denki 12VDC 4.44W DC Axial Fan for UPS, server and telecom equipment cooling

The 12 VDC Sanyo Denki 109R0812G401 is a DC axial fan sized 80 × 80 × 25 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 80.4 Pa maximum pressure is the most distinctive duty-point parameter. Check selection criteria review operating point. Focus: selection criteria review operating point.

12 80*80*25 90.1 80.4 4.44 4500 40
109P0512H701 | Sanyo Denki 12VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling

Within servers, UPS systems, and telecom equipment, 109P0512H701 provides a 52 × 52 × 15 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. The 15.1 m³/h airflow figure supports its stated equipment-cooling role. Check selection criteria review pressure capability.

12 52*52*15 15.1 31.8 1.2 4600 27
9GA0812P4H001 | Sanyo Denki 12VDC 2.64W DC Axial Fan for UPS, server and telecom equipment cooling

A 80 × 80 × 25 mm frame and 12 VDC rating define 9GA0812P4H001, a DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 2.64 W is the notable efficiency-related parameter. Focus: selection criteria review dimensional envelope.

12 80*80*25 88 - 2.64 5200 37
9S0912P4F01 | Sanyo Denki 12VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling

The 9S0912P4F01 is a Sanyo Denki 12 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. The recorded frame geometry should guide duty-point matching. Verify the exact bearing and signal options in the datasheet. Focus: selection criteria review acoustic value.

12 92*92*25 75 29.9 1.68 2650 27
109R0624H401 | Sanyo Denki 24VDC 1.44W DC Axial Fan for UPS, server and telecom equipment cooling

Within servers, UPS systems, and telecom equipment, 109R0624H401 provides a 60 × 60 × 25 mm, 24 VDC DC axial fan configuration. Series focus: high airflow and pressure. A listed input of 1.44 W is the notable efficiency-related parameter. Check selection criteria review electrical load. Focus: selection criteria review electrical load.

24 60*60*25 31.4 40.2 1.44 3800 28
9LG0824P4G001 | Sanyo Denki 24VDC 3.36W DC Axial Fan for telecommunications equipment cooling

Sanyo Denki configures 9LG0824P4G001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 25 mm dimensions. A listed input of 3.36 W is the notable efficiency-related parameter. The recorded motor input should guide thermal validation. Confirm environmental protection for the ordered version.

24 80*80*25 92.31 97.1 3.36 5500 43
9GA0824H4D001 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

The 9GA0824H4D001 is a Sanyo Denki 24 VDC, 80 × 80 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. Treat the system interface as a primary input to airflow-path design. Verify the exact bearing and signal options in the datasheet.

24 80*80*25 - - - - -
109P0424G3023 | Sanyo Denki 24VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109P0424G3023 combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. The supplied reference emphasizes high static pressure and high airflow. The 24.8 m³/h airflow figure supports its stated equipment-cooling role. Focus: cooling margin validation system interface.

24 40*40*28 24.8 179 4.56 11500 42
9G0924A201 | Sanyo Denki 24VDC 7.2W DC Axial Fan for UPS, server and telecom equipment cooling

Within servers, UPS systems, and telecom equipment, 9G0924A201 provides a 92 × 92 × 32 mm, 24 VDC DC axial fan configuration. Series focus: high airflow and pressure. Its listed airflow of 150 m³/h is the standout performance value. Check cooling margin validation cooling specification. Focus: cooling margin validation cooling specification.

24 92*92*32 150 - 7.2 4300 44
显示
41-60
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540
共 540 个
1 2 3 4 5 6 7 8 9 10 ... 26 27
跳转 页

关于三艾斯直流风扇

San Ace直流风扇是三洋电机推出的高性能直流轴流风扇,专为现代散热管理应用而设计,广泛应用于服务器与数据中心冷却、通信设备、汽车电子以及任何需要PWM调速的系统。San Ace直流产品线包括:9GA系列标准直流风扇(框架尺寸40mm至120mm,12V/24V直流,支持PWM控制)、用于服务器机架及逆变器散热的9GV系列高静压直流风扇、用于电源及通信设备机柜的大风量9WH系列直流风扇,以及适用于便携式电子设备的超小型风扇。San Ace直流风扇采用多项先进技术,包括用于实现平稳运行和低振动的三相无刷电机、用于状态监测的转速计输出,以及智能过热保护电路。在选用San Ace直流风扇时,请明确以下参数:框架尺寸、工作电压(5V/12V/24V/48V)、风量、静压,以及是否需要PWM或转速输出功能。恒瑞提供原装San Ace直流风扇,并配备完善的技术支持、交叉参考工具以及具有竞争力的定价。

如何选择合适的三艾斯直流风扇

确定三艾斯直流风扇最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 540 件产品可供选购。

三艾斯直流风扇的典型应用场景与案例

我们销售工程师的日常工作围绕三艾斯直流风扇展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 三洋 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

三艾斯直流风扇采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持三艾斯直流风扇的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。