| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 109P0412H902 | Sanyo Denki 12VDC 0.84W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109P0412H902 combines a 40 × 40 × 10 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The 9.01 m³/h airflow figure supports its stated equipment-cooling role. Focus: cabinet ventilation planning supply requirement. |
12 | 40*40*10 | 9.01 | 41.1 | 0.84 | 6200 | 25 | |
![]() 109P0512A701 | Sanyo Denki 12VDC 2.52W DC Axial Fan for UPS, server and telecom equipment cooling The 109P0512A701 is a Sanyo Denki 12 VDC, 52 × 52 × 15 mm DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For enclosure sizing, start with the supplied duty-point values. Confirm environmental protection for the ordered version. Focus: cabinet ventilation planning static-pressure entry. |
12 | 52*52*15 | 22.2 | 69.7 | 2.52 | 6800 | 36 | |
![]() 9A0924H4011 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling A 92 × 92 × 25 mm frame and 24 VDC rating define 9A0924H4011, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. 44.1 Pa maximum pressure is the most distinctive duty-point parameter. Check cabinet ventilation planning volume-flow figure. Focus: cabinet ventilation planning volume-flow figure. |
24 | 92*92*25 | 85.8 | 44.1 | 2.4 | 3150 | 33 | |
![]() 9S0924F401 | Sanyo Denki 24VDC 2.16W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 9S0924F401 provides a 92 × 92 × 25 mm, 24 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed noise figure of 27 dB is the key differentiating parameter. Check cabinet ventilation planning sound level. |
24 | 92*92*25 | 75.65 | 29.9 | 2.16 | 2650 | 27 | |
![]() 9RA0824M4001 | Sanyo Denki 24VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling The 80 × 80 × 25 mm Sanyo Denki 9RA0824M4001 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. For thermal validation, start with the supplied volume-flow figure. Use current model documentation to validate protection choices. |
24 | 80*80*25 | 44.37 | 22.4 | 0.96 | 2650 | 22 | |
![]() 109R0612S401 | Sanyo Denki 12VDC 2.04W DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 109R0612S401 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its suffix definition during controller selection. Match the exact part number before approving a substitute. Focus: cabinet ventilation planning power demand. |
12 | 60*60*25 | 38.6 | 56.8 | 2.04 | 4600 | 33 | |
![]() 9GA0612P7G01 | Sanyo Denki 12VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0612P7G01 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 15 mm dimensions. A listed input of 1.92 W is the notable efficiency-related parameter. Treat the suffix definition as a primary input to service-life planning. Use the latest specification for frequency and tolerance limits. |
12 | 60*60*15 | 41 | 80 | 1.92 | 5900 | 38 | |
![]() 109P0612S701 | Sanyo Denki 12VDC 1.8W DC Axial Fan for UPS, server and telecom equipment cooling Within servers, UPS systems, and telecom equipment, 109P0612S701 provides a 60 × 60 × 15 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 1.8 W is the notable efficiency-related parameter. Check cabinet ventilation planning cooling output. |
12 | 60*60*15 | 28.9 | 58.8 | 1.8 | 5000 | 36 | |
![]() 9RA0612P4J001 | Sanyo Denki 12VDC 4.2W DC Axial Fan for UPS, server and telecom equipment cooling The 60 × 60 × 25 mm Sanyo Denki 9RA0612P4J001 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. The recorded power demand should guide maintenance preparation. Review connector, alarm, and sensor options separately. |
12 | 60*60*25 | 65.96 | 129.5 | 4.2 | 7700 | 41 | |
![]() 9GA0424P6H001 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sized for servers, UPS systems, and telecom equipment, Sanyo Denki 9GA0424P6H001 is a 24 VDC DC axial fan in a 40 × 40 × 20 mm frame. The 20 m³/h airflow figure supports its stated equipment-cooling role. Long-life series construction is the main characteristic stated in the supplied reference. Focus: cabinet ventilation planning. |
24 | 40*40*20 | 20 | 191 | 1.92 | 12400 | 40 | |
![]() 9GA0912P4S031 | Sanyo Denki 12VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling The 92 × 92 × 25 mm Sanyo Denki 9GA0912P4S031 brings 12 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For spares assessment, start with the supplied performance curve. Confirm environmental protection for the ordered version. |
12 | 92*92*25 | 99 | 59.8 | 2.4 | 3800 | 35 | |
![]() 9GA0824H4002 | Sanyo Denki 24VDC 2.4W DC Axial Fan for UPS, server and telecom equipment cooling The 9GA0824H4002 is a Sanyo Denki 24 VDC, 80 × 80 × 25.2 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. During spares assessment, compare the model's pressure capability. Review connector, alarm, and sensor options separately. |
24 | 80*80*25.2 | 86.4 | 87.2 | 2.4 | 5200 | 37 | |
![]() 9RA0824H4002 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling For servers, UPS systems, and telecom equipment, 9RA0824H4002 combines 24 VDC operation with a 80 × 80 × 25 mm DC axial fan design. High airflow is highlighted together with a high-static-pressure design. The 80 × 80 × 25 mm format is the primary stated selection detail. Check cabinet ventilation planning electrical load. |
24 | 80*80*25 | - | - | - | - | - | |
![]() 9LB1424S5J80 | Sanyo Denki 24VDC DC Axial Fan for telecommunications equipment cooling Sanyo Denki configures 9LB1424S5J80 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 140 × 140 × 51 mm dimensions. The 140 × 140 × 51 mm format is the primary stated selection detail. Review its system interface during replacement evaluation. Treat bearing and life data as suffix-specific. |
24 | 140*140*51 | - | - | - | - | - | |
![]() 9GA0824P2S001 | Sanyo Denki 24VDC 10.1W DC Axial Fan for UPS, server and telecom equipment cooling Built around servers, UPS systems, and telecom equipment, Sanyo Denki 9GA0824P2S001 is a 24 VDC DC axial fan in a 80 × 80 × 32 mm frame. 361.2 Pa maximum pressure is the most distinctive duty-point parameter. Long-life series construction is the main characteristic stated in the supplied reference. Focus: cabinet ventilation planning. |
24 | 80*80*32 | 147.05 | 361.2 | 10.1 | 9700 | 57 | |
![]() 9A0924F402 | Sanyo Denki 24VDC 1.92W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9A0924F402 is a 24 VDC DC axial fan in a 92 × 92 × 25 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its 2650 rpm rating defines a lower-speed operating point. Check equipment integration review system interface. Focus: equipment integration review system interface. |
24 | 92*92*25 | 73.8 | 32.1 | 1.92 | 2650 | 30 | |
![]() 9GV1212P1J01 | Sanyo Denki 12VDC 36W DC Axial Fan for automation and control cabinet cooling Within industrial controls, power cabinets, and energy systems, Sanyo Denki 9GV1212P1J01 operates as a 120 × 120 × 38 mm DC axial fan at 12 VDC. High airflow is highlighted together with a high-static-pressure design. The supplied row lists 64 dB as an important acoustic selection value. Focus: equipment integration review cooling specification. |
12 | 120*120*38 | 380.8 | 361.2 | 36 | 6400 | 64 | |
![]() 9S0612F401 | Sanyo Denki 12VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9S0612F401 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 60 × 60 × 25 mm dimensions. A listed noise figure of 20 dB is the key differentiating parameter. Review its operating point during controller selection. Review connector, alarm, and sensor options separately. |
12 | 60*60*25 | 29.41 | 29.9 | 0.96 | 3300 | 20 | |
![]() 9WPA0624P4G001 | Sanyo Denki 24VDC 11.04W DC Axial Fan for solar inverter and energy storage cooling For thermal management in outdoor equipment and photovoltaic inverters, the 9WPA0624P4G001 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 12000 rpm is the model's most prominent operating value. The recorded airflow profile should guide procurement comparison. Match the exact part number before approving a substitute. |
24 | 60*60*25 | 91.2 | 357 | 11.04 | 12000 | 56 | |
![]() 9WE1724K501 | Sanyo Denki 24VDC 31.2W DC Axial Fan for solar inverter and energy storage cooling Equipment designers serving outdoor equipment and photovoltaic inverters can evaluate Sanyo Denki 9WE1724K501, a DC axial fan rated at 24 VDC and sized ø172 × 51 mm. Its listed airflow of 504 m³/h is the standout performance value. Review its pressure capability during maintenance preparation. Validate mounting and wiring from the model drawing. |
24 | ø172*51 | 504 | 241.6 | 31.2 | 4100 | 55 |
确定三艾斯直流风扇最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 540 件产品可供选购。
我们销售工程师的日常工作围绕三艾斯直流风扇展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 三洋 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。