获取报价
首页 > 产品 > 按品牌 > 三洋 > 三艾斯直流风扇

三艾斯直流风扇

按类型

按行业

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

库存选项

环保选项

资料

排除

540 个结果

已选条件

显示
81-100
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540
共 540 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
9G0924H202 | Sanyo Denki 24VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9G0924H202 provides a 24 VDC DC axial fan configuration measuring 92 × 92 × 32 mm. Its 2850 rpm rating defines a lower-speed operating point. Use the documented acoustic value when planning thermal validation. Use the latest specification for frequency and tolerance limits.

24 92*92*32 94.2 51.2 2.88 2850 32
9G1224H401 | Sanyo Denki 24VDC 4.08W DC Axial Fan for UPS, server and telecom equipment cooling

The 24 VDC Sanyo Denki 9G1224H401 is a DC axial fan sized 120 × 120 × 25 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Its 2850 rpm rating defines a lower-speed operating point. Check cooling margin validation dimensional envelope. Focus: cooling margin validation.

24 120*120*25 149.6 - 4.08 2850 40
9GA0924H402 | Sanyo Denki 24VDC 2.16W DC Axial Fan for UPS, server and telecom equipment cooling

The 9GA0924H402 is a Sanyo Denki 24 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For power-budget planning, start with the supplied frame geometry. Treat bearing and life data as suffix-specific.

24 92*92*25 87.04 - 2.16 3300 31
9GA0612H6001 | Sanyo Denki 12VDC 1.08W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9GA0612H6001 combines a 60 × 60 × 20 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 1.08 W is the notable efficiency-related parameter. Focus: cooling margin validation.

12 60*60*20 31.28 44.8 1.08 4100 29
9GA0824H7D001 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 9GA0824H7D001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 15 mm dimensions. A listed input of 1.2 W is the notable efficiency-related parameter. During duty-point matching, compare the model's duty-point values. Verify the exact bearing and signal options in the datasheet.

24 80*80*15 52.7 32.4 1.2 3800 29
9HV0412P3K001 | Sanyo Denki 12VDC 18.3W DC Axial Fan for AI servers and high-density equipment cooling

9HV0412P3K001 addresses AI servers and high-density electronics through a 12 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Ultra-high static-pressure capability is the representative series characteristic. 25000 rpm is the model's most prominent operating value. Check cooling margin validation airflow profile.

12 40*40*28 50 1100 18.3 25000 65
9G1212H401 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling

9G1212H401 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 120 × 120 × 25 mm. Series focus: high airflow and pressure. Its 2850 rpm rating defines a lower-speed operating point. Check cabinet ventilation planning system interface. Focus: cabinet ventilation planning system interface.

12 120*120*25 149.6 210 3.72 2850 40
109P0424H6D19 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0424H6D19 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 40 × 40 × 20 mm. High airflow is highlighted together with a high-static-pressure design. The 40 × 40 × 20 mm format is the primary stated selection detail. Check cabinet ventilation planning cooling specification.

24 40*40*20 - - - - -
9WF0624H701 | Sanyo Denki 24VDC 2.88W DC Axial Fan for industrial equipment and cabinet cooling

Within industrial controls, power cabinets, and energy systems, Sanyo Denki 9WF0624H701 operates as a 60 × 60 × 15 mm DC axial fan at 24 VDC. Its oil-resistant fan design and IP20 listing is the defining supplied feature. The 31.11 m³/h airflow figure supports its stated equipment-cooling role. Focus: cabinet ventilation planning duty-point values.

24 60*60*15 31.11 94.6 2.88 6800 44
109E5724H501 | Sanyo Denki 24VDC 13.92W DC Axial Fan for UPS, server and telecom equipment cooling

The 24 VDC Sanyo Denki 109E5724H501 is a DC axial fan sized 172 × 150 × 51 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 384 m³/h is the standout performance value. Check cabinet ventilation planning installation footprint. Focus: cabinet ventilation planning.

24 172*150*51 384 137.2 13.92 3050 52
9GL1224G102 | Sanyo Denki 24VDC 12W DC Axial Fan for UPS, server and telecom equipment cooling

A 119 × 119 × 38 mm frame and 24 VDC rating define 9GL1224G102, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 230.4 m³/h is the standout performance value. Check cabinet ventilation planning selection parameters. Focus: cabinet ventilation planning.

24 119*119*38 230.4 135 12 3600 49
109P0512H720 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling

109P0512H720 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 52 × 52 × 15 mm. Series focus: high airflow and pressure. The 52 × 52 × 15 mm format is the primary stated selection detail. Check cabinet ventilation planning rated dataset. Focus: cabinet ventilation planning rated dataset.

12 52*52*15 - - - - -
9A0912S401 | Sanyo Denki 12VDC 3.24W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9A0912S401 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 56.1 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: cabinet ventilation planning motor input.

12 92*92*25 100 56.1 3.24 3550 39
109E1348G101 | Sanyo Denki 48VDC 25.9W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki configures 109E1348G101 for servers, UPS systems, and telecom equipment as a 48 VDC DC axial fan with 127 × 127 × 38 mm dimensions. Its listed airflow of 340 m³/h is the standout performance value. During cooling-margin review, compare the model's equipment fit. Use the latest specification for frequency and tolerance limits.

48 127*127*38 340 216 25.9 4550 57
109R0612G429 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling

109R0612G429 serves servers, UPS systems, and telecom equipment as a 60 × 60 × 25 mm DC axial fan rated at 12 VDC. Series focus: high airflow and pressure. The 60 × 60 × 25 mm format is the primary stated selection detail. Check cabinet ventilation planning equipment fit. Focus: cabinet ventilation planning equipment fit.

12 60*60*25 - - - - -
109P0912H402 | Sanyo Denki 12VDC 2.52W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 109P0912H402 provides a 12 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Its 2850 rpm rating defines a lower-speed operating point. During enclosure sizing, compare the model's acoustic value. Confirm environmental protection for the ordered version.

12 92*92*25 87.04 45.1 2.52 2850 33
109P0405M902 | Sanyo Denki 5VDC 0.55W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 109P0405M902 is a 5 VDC DC axial fan in a 40 × 40 × 10 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. A listed input of 0.55 W is the notable efficiency-related parameter. Check cabinet ventilation planning catalog specification. Focus: cabinet ventilation planning.

5 40*40*10 7.14 27 0.55 5000 21
9G0812G1D01 | Sanyo Denki 12VDC 13.2W DC Axial Fan for UPS, server and telecom equipment cooling

For thermal management in servers, UPS systems, and telecom equipment, the 9G0812G1D01 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 13.2 W input is the defining electrical-load figure. The recorded acoustic value should guide duty-point matching. Obtain the applicable curve before final duty-point approval.

12 80*80*38 151.2 211 13.2 6300 51
9A0612G4011 | Sanyo Denki 12VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling

Sanyo Denki 9A0612G4011 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed input of 2.88 W is the notable efficiency-related parameter. Selection focus: cabinet ventilation planning performance curve.

12 60*60*25 47 87.3 2.88 5600 39
109R0824L4011 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling

109R0824L4011 serves servers, UPS systems, and telecom equipment as a 80 × 80 × 25 mm DC axial fan rated at 24 VDC. High airflow is highlighted together with a high-static-pressure design. 14.7 Pa maximum pressure is the most distinctive duty-point parameter. Check cabinet ventilation planning mounting size. Focus: cabinet ventilation planning.

24 80*80*25 38.6 14.7 - 1850 20
显示
81-100
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540
共 540 个
1 2 3 4 5 6 7 8 9 10 ... 26 27
跳转 页

关于三艾斯直流风扇

San Ace直流风扇是三洋电机推出的高性能直流轴流风扇,专为现代散热管理应用而设计,广泛应用于服务器与数据中心冷却、通信设备、汽车电子以及任何需要PWM调速的系统。San Ace直流产品线包括:9GA系列标准直流风扇(框架尺寸40mm至120mm,12V/24V直流,支持PWM控制)、用于服务器机架及逆变器散热的9GV系列高静压直流风扇、用于电源及通信设备机柜的大风量9WH系列直流风扇,以及适用于便携式电子设备的超小型风扇。San Ace直流风扇采用多项先进技术,包括用于实现平稳运行和低振动的三相无刷电机、用于状态监测的转速计输出,以及智能过热保护电路。在选用San Ace直流风扇时,请明确以下参数:框架尺寸、工作电压(5V/12V/24V/48V)、风量、静压,以及是否需要PWM或转速输出功能。恒瑞提供原装San Ace直流风扇,并配备完善的技术支持、交叉参考工具以及具有竞争力的定价。

如何选择合适的三艾斯直流风扇

确定三艾斯直流风扇最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 540 件产品可供选购。

三艾斯直流风扇的典型应用场景与案例

我们销售工程师的日常工作围绕三艾斯直流风扇展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 三洋 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

三艾斯直流风扇采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持三艾斯直流风扇的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。