| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() 9G0924H202 | Sanyo Denki 24VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9G0924H202 provides a 24 VDC DC axial fan configuration measuring 92 × 92 × 32 mm. Its 2850 rpm rating defines a lower-speed operating point. Use the documented acoustic value when planning thermal validation. Use the latest specification for frequency and tolerance limits. |
24 | 92*92*32 | 94.2 | 51.2 | 2.88 | 2850 | 32 | |
![]() 9G1224H401 | Sanyo Denki 24VDC 4.08W DC Axial Fan for UPS, server and telecom equipment cooling The 24 VDC Sanyo Denki 9G1224H401 is a DC axial fan sized 120 × 120 × 25 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Its 2850 rpm rating defines a lower-speed operating point. Check cooling margin validation dimensional envelope. Focus: cooling margin validation. |
24 | 120*120*25 | 149.6 | - | 4.08 | 2850 | 40 | |
![]() 9GA0924H402 | Sanyo Denki 24VDC 2.16W DC Axial Fan for UPS, server and telecom equipment cooling The 9GA0924H402 is a Sanyo Denki 24 VDC, 92 × 92 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. For power-budget planning, start with the supplied frame geometry. Treat bearing and life data as suffix-specific. |
24 | 92*92*25 | 87.04 | - | 2.16 | 3300 | 31 | |
![]() 9GA0612H6001 | Sanyo Denki 12VDC 1.08W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9GA0612H6001 combines a 60 × 60 × 20 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. Long-life series construction is the main characteristic stated in the supplied reference. A listed input of 1.08 W is the notable efficiency-related parameter. Focus: cooling margin validation. |
12 | 60*60*20 | 31.28 | 44.8 | 1.08 | 4100 | 29 | |
![]() 9GA0824H7D001 | Sanyo Denki 24VDC 1.2W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 9GA0824H7D001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 15 mm dimensions. A listed input of 1.2 W is the notable efficiency-related parameter. During duty-point matching, compare the model's duty-point values. Verify the exact bearing and signal options in the datasheet. |
24 | 80*80*15 | 52.7 | 32.4 | 1.2 | 3800 | 29 | |
![]() 9HV0412P3K001 | Sanyo Denki 12VDC 18.3W DC Axial Fan for AI servers and high-density equipment cooling 9HV0412P3K001 addresses AI servers and high-density electronics through a 12 VDC DC axial fan platform measuring 40 × 40 × 28 mm. Ultra-high static-pressure capability is the representative series characteristic. 25000 rpm is the model's most prominent operating value. Check cooling margin validation airflow profile. |
12 | 40*40*28 | 50 | 1100 | 18.3 | 25000 | 65 | |
![]() 9G1212H401 | Sanyo Denki 12VDC 3.72W DC Axial Fan for UPS, server and telecom equipment cooling 9G1212H401 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 120 × 120 × 25 mm. Series focus: high airflow and pressure. Its 2850 rpm rating defines a lower-speed operating point. Check cabinet ventilation planning system interface. Focus: cabinet ventilation planning system interface. |
12 | 120*120*25 | 149.6 | 210 | 3.72 | 2850 | 40 | |
![]() 109P0424H6D19 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling 109P0424H6D19 addresses servers, UPS systems, and telecom equipment through a 24 VDC DC axial fan platform measuring 40 × 40 × 20 mm. High airflow is highlighted together with a high-static-pressure design. The 40 × 40 × 20 mm format is the primary stated selection detail. Check cabinet ventilation planning cooling specification. |
24 | 40*40*20 | - | - | - | - | - | |
![]() 9WF0624H701 | Sanyo Denki 24VDC 2.88W DC Axial Fan for industrial equipment and cabinet cooling Within industrial controls, power cabinets, and energy systems, Sanyo Denki 9WF0624H701 operates as a 60 × 60 × 15 mm DC axial fan at 24 VDC. Its oil-resistant fan design and IP20 listing is the defining supplied feature. The 31.11 m³/h airflow figure supports its stated equipment-cooling role. Focus: cabinet ventilation planning duty-point values. |
24 | 60*60*15 | 31.11 | 94.6 | 2.88 | 6800 | 44 | |
![]() 109E5724H501 | Sanyo Denki 24VDC 13.92W DC Axial Fan for UPS, server and telecom equipment cooling The 24 VDC Sanyo Denki 109E5724H501 is a DC axial fan sized 172 × 150 × 51 mm for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 384 m³/h is the standout performance value. Check cabinet ventilation planning installation footprint. Focus: cabinet ventilation planning. |
24 | 172*150*51 | 384 | 137.2 | 13.92 | 3050 | 52 | |
![]() 9GL1224G102 | Sanyo Denki 24VDC 12W DC Axial Fan for UPS, server and telecom equipment cooling A 119 × 119 × 38 mm frame and 24 VDC rating define 9GL1224G102, a DC axial fan for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Its listed airflow of 230.4 m³/h is the standout performance value. Check cabinet ventilation planning selection parameters. Focus: cabinet ventilation planning. |
24 | 119*119*38 | 230.4 | 135 | 12 | 3600 | 49 | |
![]() 109P0512H720 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling 109P0512H720 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 52 × 52 × 15 mm. Series focus: high airflow and pressure. The 52 × 52 × 15 mm format is the primary stated selection detail. Check cabinet ventilation planning rated dataset. Focus: cabinet ventilation planning rated dataset. |
12 | 52*52*15 | - | - | - | - | - | |
![]() 9A0912S401 | Sanyo Denki 12VDC 3.24W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9A0912S401 combines a 92 × 92 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. 56.1 Pa maximum pressure is the most distinctive duty-point parameter. Selection focus: cabinet ventilation planning motor input. |
12 | 92*92*25 | 100 | 56.1 | 3.24 | 3550 | 39 | |
![]() 109E1348G101 | Sanyo Denki 48VDC 25.9W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki configures 109E1348G101 for servers, UPS systems, and telecom equipment as a 48 VDC DC axial fan with 127 × 127 × 38 mm dimensions. Its listed airflow of 340 m³/h is the standout performance value. During cooling-margin review, compare the model's equipment fit. Use the latest specification for frequency and tolerance limits. |
48 | 127*127*38 | 340 | 216 | 25.9 | 4550 | 57 | |
![]() 109R0612G429 | Sanyo Denki 12VDC DC Axial Fan for UPS, server and telecom equipment cooling 109R0612G429 serves servers, UPS systems, and telecom equipment as a 60 × 60 × 25 mm DC axial fan rated at 12 VDC. Series focus: high airflow and pressure. The 60 × 60 × 25 mm format is the primary stated selection detail. Check cabinet ventilation planning equipment fit. Focus: cabinet ventilation planning equipment fit. |
12 | 60*60*25 | - | - | - | - | - | |
![]() 109P0912H402 | Sanyo Denki 12VDC 2.52W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 109P0912H402 provides a 12 VDC DC axial fan configuration measuring 92 × 92 × 25 mm. Its 2850 rpm rating defines a lower-speed operating point. During enclosure sizing, compare the model's acoustic value. Confirm environmental protection for the ordered version. |
12 | 92*92*25 | 87.04 | 45.1 | 2.52 | 2850 | 33 | |
![]() 109P0405M902 | Sanyo Denki 5VDC 0.55W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 109P0405M902 is a 5 VDC DC axial fan in a 40 × 40 × 10 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. A listed input of 0.55 W is the notable efficiency-related parameter. Check cabinet ventilation planning catalog specification. Focus: cabinet ventilation planning. |
5 | 40*40*10 | 7.14 | 27 | 0.55 | 5000 | 21 | |
![]() 9G0812G1D01 | Sanyo Denki 12VDC 13.2W DC Axial Fan for UPS, server and telecom equipment cooling For thermal management in servers, UPS systems, and telecom equipment, the 9G0812G1D01 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 38 mm. 13.2 W input is the defining electrical-load figure. The recorded acoustic value should guide duty-point matching. Obtain the applicable curve before final duty-point approval. |
12 | 80*80*38 | 151.2 | 211 | 13.2 | 6300 | 51 | |
![]() 9A0612G4011 | Sanyo Denki 12VDC 2.88W DC Axial Fan for UPS, server and telecom equipment cooling Sanyo Denki 9A0612G4011 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed input of 2.88 W is the notable efficiency-related parameter. Selection focus: cabinet ventilation planning performance curve. |
12 | 60*60*25 | 47 | 87.3 | 2.88 | 5600 | 39 | |
![]() 109R0824L4011 | Sanyo Denki 24VDC DC Axial Fan for UPS, server and telecom equipment cooling 109R0824L4011 serves servers, UPS systems, and telecom equipment as a 80 × 80 × 25 mm DC axial fan rated at 24 VDC. High airflow is highlighted together with a high-static-pressure design. 14.7 Pa maximum pressure is the most distinctive duty-point parameter. Check cabinet ventilation planning mounting size. Focus: cabinet ventilation planning. |
24 | 80*80*25 | 38.6 | 14.7 | - | 1850 | 20 |
确定三艾斯直流风扇最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 540 件产品可供选购。
我们销售工程师的日常工作围绕三艾斯直流风扇展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 三洋 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。