| 制造商料号 | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() VF60381B1-0000-A9H | SUNON 12V 12W 60x60x38mm 91.9m3/h DC Axial Fan for Data Center Cooling Built for servers and data-center electronics, SUNON VF60381B1-0000-A9H uses a 60 × 60 × 38 mm DC axial fan arrangement at 12 VDC. 1053.7 Pa maximum pressure is the standout documented duty-point value. The recorded suffix definition should guide project documentation. Reconcile the model code with the required electrical interface. |
12 | 60x60x38mm | 91.9 | 1053.7 | 12 | 18300 | 60.9 | |
![]() VF40281BX-0000-A9H | SUNON 12V 13.68W 40x40x28mm 53.5m3/h DC Axial Fan for Data Center Cooling The VF40281BX-0000-A9H is SUNON's 12 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 27000 rpm is the model's most distinctive operating parameter. For project documentation, start with the supplied catalog specification. Reconcile the model code with the required electrical interface. |
12 | 40x40x28mm | 53.5 | 983.9 | 13.68 | 27000 | 63.7 | |
![]() VF40281B1-0000-A9H | SUNON 12V 7.56W 40x40x28mm 43.5m3/h DC Axial Fan for Data Center Cooling A 40 × 40 × 28 mm frame and 12 VDC rating define VF40281B1-0000-A9H, a DC axial fan for servers and data-center electronics. 21600 rpm is the model's most distinctive operating parameter. Use the documented thermal-duty record when planning project documentation. Reconcile the model code with the required electrical interface. |
12 | 40x40x28mm | 43.5 | 690 | 7.56 | 21600 | 58.6 | |
![]() VF38561BX-10000-A9T | SUNON 12V 14.4W 38x38x56mm 53m3/h DC Axial Fan for Data Center Cooling SUNON VF38561BX-10000-A9T combines a 38 × 38 × 56 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 29300 rpm is the model's most distinctive operating parameter. Review its performance curve during project documentation. Reconcile the model code with the required electrical interface. |
12 | 38x38x56mm | 53 | 1145.8 | 14.4 | 29300 | 61.6 | |
![]() VF38281BX-0000-A9H | SUNON 12V 10.44W 38x38x28mm 41.1m3/h DC Axial Fan for Data Center Cooling Engineered for servers and data-center electronics, SUNON VF38281BX-0000-A9H is a 12 VDC DC axial fan in a 38 × 38 × 28 mm frame. 27000 rpm is the model's most distinctive operating parameter. Treat the mounting size as a primary input to project documentation. Reconcile the model code with the required electrical interface. |
12 | 38x38x28mm | 41.1 | 886.8 | 10.44 | 27000 | 61.6 | |
![]() VF38281B1-0000-A9H | SUNON 12V 5.7W 38x38x28mm 32.1m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON VF38281B1-0000-A9H serves as a 38 × 38 × 28 mm DC axial fan operating at 12 VDC. 21600 rpm is the model's most distinctive operating parameter. Base project documentation on the stated supply requirement. Reconcile the model code with the required electrical interface. |
12 | 38x38x28mm | 32.1 | 622.7 | 5.7 | 21600 | 58.1 | |
![]() VF60381BX-Q08U-Q9I | SUNON 12V 22.8W 60x60x38mm 115.2m3/h DC Axial Fan for Industrial Cooling VF60381BX-Q08U-Q9I serves servers and data-center electronics as a 60 × 60 × 38 mm DC axial fan rated at 12 VDC. 1205.6 Pa maximum pressure is the standout documented duty-point value. During project documentation, compare the model's static-pressure entry. Reconcile the model code with the required electrical interface. |
12 | 60x60x38mm | 115.2 | 1205.6 | 22.8 | 22800 | 64.1 | |
![]() VF60381BX-Q090-S9H | SUNON 12V 22.8W 60x60x38mm 115.2m3/h DC Axial Fan for Data Center Cooling The VF60381BX-Q090-S9H is SUNON's 12 VDC, 60 × 60 × 38 mm DC axial fan option for servers and data-center electronics. 1205.6 Pa maximum pressure is the standout documented duty-point value. The recorded volume-flow figure should guide project documentation. Reconcile the model code with the required electrical interface. |
12 | 60x60x38mm | 115.2 | 1205.6 | 22.8 | 22800 | 64.1 | |
![]() VF80381B1-1Q04U-S9H | SUNON 12V 33.12W 80x80x38mm 125.2m3/h DC Axial Fan for Data Center Cooling SUNON VF80381B1-1Q04U-S9H is a 12 VDC DC blower in a 80 × 80 × 38 mm format for servers and data-center electronics. 1.84 Pa maximum pressure is the standout documented duty-point value. For project documentation, start with the supplied sound level. Reconcile the model code with the required electrical interface. |
12 | 80x80x38 | 125.2 | 1.84 | 33.12 | 10800 | 60.6 | |
![]() XG40561BX-1Q310-S9H | SUNON 40x40x56mm DC Axial Fan for Data Center Cooling SUNON XG40561BX-1Q310-S9H combines a 40 × 40 × 56 mm DC blower platform with a 0 VDC rating for servers and data-center electronics. Its 40 × 40 × 56 mm format is the main stated selection detail. Use the documented rotational rating when planning project documentation. Reconcile the model code with the required electrical interface. |
0 | 40x40x56 | - | - | - | - | - | |
![]() XG40561BX-1QC30-S9H | SUNON 40x40x56mm DC Axial Fan for Industrial Cooling Sized for servers and data-center electronics, SUNON XG40561BX-1QC30-S9H is a 0 VDC DC blower in a 40 × 40 × 56 mm frame. Its 40 × 40 × 56 mm format is the main stated selection detail. Review its power demand during project documentation. Reconcile the model code with the required electrical interface. |
0 | 40x40x56 | - | - | - | - | - | |
![]() XG40561BX-1Q341-S9H | SUNON 40x40x56mm DC Axial Fan for Industrial Cooling Within servers and data-center electronics, SUNON XG40561BX-1Q341-S9H serves as a 40 × 40 × 56 mm DC blower operating at 0 VDC. Its 40 × 40 × 56 mm format is the main stated selection detail. Treat the frame geometry as a primary input to project documentation. Reconcile the model code with the required electrical interface. |
0 | 40x40x56 | - | - | - | - | - | |
![]() XG60561BX-1Q029-S9I | SUNON 60x60x56mm DC Axial Fan for Industrial Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON XG60561BX-1Q029-S9I, a DC blower rated at 0 VDC and sized 60 × 60 × 56 mm. Its 60 × 60 × 56 mm format is the main stated selection detail. Base project documentation on the stated cooling output. Reconcile the model code with the required electrical interface. |
0 | 60x60x56 | - | - | - | - | - | |
![]() XG60561BX-1Q248-S9W | SUNON 60x60x56mm DC Axial Fan for Industrial Cooling The XG60561BX-1Q248-S9W is SUNON's 0 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. Its 60 × 60 × 56 mm format is the main stated selection detail. During project documentation, compare the model's operating point. Reconcile the model code with the required electrical interface. |
0 | 60x60x56 | - | - | - | - | - | |
![]() XG40561BX-1Q25U-S9T | SUNON 40x40x56mm DC Axial Fan for Data Center Cooling SUNON configures XG40561BX-1Q25U-S9T as a 40 × 40 × 56 mm DC blower for servers and data-center electronics, operating at 0 VDC. Its 40 × 40 × 56 mm format is the main stated selection detail. The recorded pressure capability should guide project documentation. Reconcile the model code with the required electrical interface. |
0 | 40x40x56 | - | - | - | - | - | |
![]() XG40561BX-1Q461-Q9T | SUNON 40x40x56mm DC Axial Fan for Industrial Cooling SUNON XG40561BX-1Q461-Q9T combines a 40 × 40 × 56 mm DC blower platform with a 0 VDC rating for servers and data-center electronics. Its 40 × 40 × 56 mm format is the main stated selection detail. For project documentation, start with the supplied dimensional envelope. Reconcile the model code with the required electrical interface. |
0 | 40x40x56 | - | - | - | - | - | |
![]() VG40561BX-0000-A9H | SUNON 12V 16.8W 40x40x56mm 42.5m3/h DC Axial Fan for Data Center Cooling Designed for servers and data-center electronics, SUNON VG40561BX-0000-A9H is a 12 VDC DC axial fan in a 40 × 40 × 56 mm frame. 1541.9 Pa maximum pressure is the standout documented duty-point value. Use the documented acoustic value when planning project documentation. Reconcile the model code with the required electrical interface. |
12 | 40x40x56mm | 42.5 | 1541.9 | 16.8 | - | 65 | |
![]() VG40561B1-0000-A9H | SUNON 12V 9W 40x40x56mm 33.5m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON VG40561B1-0000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 1036.2 Pa maximum pressure is the standout documented duty-point value. Review its electrical load during project documentation. Reconcile the model code with the required electrical interface. |
12 | 40x40x56mm | 33.5 | 1036.2 | 9 | - | 62.5 | |
![]() VG60561BX-Q158-Q9T | SUNON 12V 60x60x56mm DC Axial Fan for Industrial Cooling For servers and data-center electronics, VG60561BX-Q158-Q9T combines 12 VDC operation with a 60 × 60 × 56 mm DC blower design. Its 60 × 60 × 56 mm format is the main stated selection detail. Treat the speed benchmark as a primary input to project documentation. Reconcile the model code with the required electrical interface. |
12 | 60x60x56 | - | - | - | - | - | |
![]() VG60561BX-1Q014-S9HP | SUNON 12V 61.2W 60x60x56mm 140m3/h DC Axial Fan for Data Center Cooling The VG60561BX-1Q014-S9HP is SUNON's 12 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. 18400 rpm is the model's most distinctive operating parameter. Base project documentation on the stated airflow profile. Reconcile the model code with the required electrical interface. |
12 | 60x60x56 | 140 | - | 61.2 | 18400 | 79.1 |
确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。
电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。
接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。
流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。
我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。
一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。
制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。
从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。
欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。
可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。
每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。
袋装
袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。