获取报价
首页 > 产品 > 按品牌 > SUNON > DC粉丝

DC粉丝

按类型

按行业

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

库存选项

环保选项

资料

排除

1,011 个结果

已选条件

显示
61-80
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
下载表格
制造商料号 Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
XG40561BX-1Q012-S9H | SUNON 12V 27.6W 40x40x56mm 34.6m3/h DC Axial Fan for Industrial Cooling

SUNON configures XG40561BX-1Q012-S9H as a 40 × 40 × 56 mm DC blower for servers and data-center electronics, operating at 12 VDC. 7.46 Pa maximum pressure is the standout documented duty-point value. Base application screening on the stated performance curve. Validate approvals and protection at complete-part-number level.

12 40x40x56 34.6 7.46 27.6 29700/25000 72
XF40561BX-Q023-S9H | SUNON 12V 30W 40x40x56mm 33.6m3/h DC Axial Fan for Data Center Cooling

The XF40561BX-Q023-S9H is SUNON's 12 VDC, 40 × 40 × 56 mm DC blower option for servers and data-center electronics. 7.6 Pa maximum pressure is the standout documented duty-point value. During application screening, compare the model's mounting size. Validate approvals and protection at complete-part-number level.

12 40x40x56 33.6 7.6 30 30000/27200 69.5
XF40561BX-10000-S9T | SUNON 12V 33.6W 40x40x56mm 34.5m3/h DC Axial Fan for Industrial Cooling

The 12 VDC SUNON XF40561BX-10000-S9T is a DC blower sized 40 × 40 × 56 mm for servers and data-center electronics. 8.7 Pa maximum pressure is the standout documented duty-point value. The recorded supply requirement should guide application screening. Validate approvals and protection at complete-part-number level.

12 40x40x56 34.5 8.7 33.6 30500/28000 70.1
VG40561BX-0000-S9H | SUNON 12V 16.8W 40x40x56mm 25m3/h DC Axial Fan for Industrial Cooling

SUNON VG40561BX-0000-S9H combines a 40 × 40 × 56 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 6.19 Pa maximum pressure is the standout documented duty-point value. For application screening, start with the supplied static-pressure entry. Validate approvals and protection at complete-part-number level.

12 40x40x56 25 6.19 16.8 25500/23000 65
VF40561BX-0000-S9H | SUNON 12V 12.6W 40x40x56mm 31.5m3/h DC Axial Fan for Industrial Cooling

Used in servers and data-center electronics, SUNON VF40561BX-0000-S9H is a 12 VDC DC blower in a 40 × 40 × 56 mm frame. 24000 rpm is the model's most distinctive operating parameter. Use the documented volume-flow figure when planning application screening. Validate approvals and protection at complete-part-number level.

12 40x40x56 31.5 3.77 12.6 24000 60.6
PF40561BX-QA31-S9H | SUNON 12V 22.8W 40x40x56mm 34.8m3/h DC Axial Fan for Industrial Cooling

Within servers and data-center electronics, SUNON PF40561BX-QA31-S9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 4.31 Pa maximum pressure is the standout documented duty-point value. Review its sound level during application screening. Validate approvals and protection at complete-part-number level.

12 40x40x56 34.8 4.31 22.8 23300/20300 69.4
PF40561BX-10000-S9H | SUNON 12V 16.68W 40x40x56mm 31.7m3/h DC Axial Fan for Industrial Cooling

Specified at 12 VDC, PF40561BX-10000-S9H is a SUNON DC axial fan for servers and data-center electronics in 40 × 40 × 56 mm dimensions. 3.76 Pa maximum pressure is the standout documented duty-point value. Treat the rotational rating as a primary input to application screening. Validate approvals and protection at complete-part-number level.

12 40x40x56 31.7 3.76 16.68 21500/18000 65.9
PF40561BX-0000-S99 | SUNON 12V 16.68W 40x40x56mm 31.7m3/h DC Axial Fan for Industrial Cooling

The PF40561BX-0000-S99 is SUNON's 12 VDC, 40 × 40 × 56 mm DC axial fan option for servers and data-center electronics. 3.6 Pa maximum pressure is the standout documented duty-point value. Base application screening on the stated power demand. Validate approvals and protection at complete-part-number level.

12 40x40x56 31.7 3.6 16.68 21500/18000 65.9
XG40284BX-1Q030-S9H | SUNON 48V 43.7W 40x40x28mm 46.39m3/h DC Axial Fan for Industrial Cooling

For compact cooling within servers and data-center electronics, the XG40284BX-1Q030-S9H provides a 48 VDC DC blower configuration measuring 40 × 40 × 28 mm. 37000 rpm is the model's most distinctive operating parameter. During application screening, compare the model's frame geometry. Validate approvals and protection at complete-part-number level.

48 40x40x28 46.39 9.9 43.7 37000 TBD
XG40281BX-1Q030-S9T | SUNON 12V 27W 40x40x28mm 39.9m3/h DC Axial Fan for Industrial Cooling

SUNON XG40281BX-1Q030-S9T combines a 40 × 40 × 28 mm DC blower platform with a 12 VDC rating for servers and data-center electronics. 33000 rpm is the model's most distinctive operating parameter. The recorded cooling output should guide application screening. Validate approvals and protection at complete-part-number level.

12 40x40x28 39.9 6.66 27 33000 69.9
XF40281BX-Q032-S9H | SUNON 12V 28.2W 40x40x28mm 38.6m3/h DC Axial Fan for Data Center Cooling

Applied in servers and data-center electronics, SUNON XF40281BX-Q032-S9H is a 12 VDC DC blower in a 40 × 40 × 28 mm frame. 33000 rpm is the model's most distinctive operating parameter. For application screening, start with the supplied operating point. Validate approvals and protection at complete-part-number level.

12 40x40x28 38.6 5.83 28.2 33000 70.1
XF40281BX-Q014-S9H | SUNON 12V 18W 40x40x28mm 31m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON XF40281BX-Q014-S9H serves as a 40 × 40 × 28 mm DC blower operating at 12 VDC. 36000 rpm is the model's most distinctive operating parameter. Use the documented pressure capability when planning application screening. Validate approvals and protection at complete-part-number level.

12 40x40x28 31 6.8 18 36000 68.7
XF40281BX-10000-S9T | SUNON 12V 28.8W 40x40x28mm 39.3m3/h DC Axial Fan for Industrial Cooling

Within servers and data-center electronics, XF40281BX-10000-S9T provides a 40 × 40 × 28 mm, 12 VDC DC blower configuration. 33000 rpm is the model's most distinctive operating parameter. Review its dimensional envelope during application screening. Validate approvals and protection at complete-part-number level.

12 40x40x28 39.3 6.39 28.8 33000 71.8
VF40281BX-1Q010-S9H | SUNON 12V 22.8W 40x40x28mm 36.9m3/h DC Axial Fan for Industrial Cooling

The VF40281BX-1Q010-S9H is SUNON's 12 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. 27000 rpm is the model's most distinctive operating parameter. Treat the acoustic value as a primary input to application screening. Validate approvals and protection at complete-part-number level.

12 40x40x28 36.9 4.48 22.8 27000 64.1
VF40281BX-Q09U-S9H | SUNON 12V 17.04W 40x40x28mm 32.5m3/h DC Axial Fan for Industrial Cooling

For thermal management in servers and data-center electronics, the VF40281BX-Q09U-S9H provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 28600 rpm is the model's most distinctive operating parameter. Base application screening on the stated electrical load. Validate approvals and protection at complete-part-number level.

12 40x40x28 32.5 4.17 17.04 28600 63.8
PF40281BX-D089-S99 | SUNON 12V 13.8W 40x40x28mm 31.6m3/h DC Axial Fan for Data Center Cooling

SUNON PF40281BX-D089-S99 combines a 40 × 40 × 28 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 3.25 Pa maximum pressure is the standout documented duty-point value. During application screening, compare the model's speed benchmark. Validate approvals and protection at complete-part-number level.

12 40x40x28 31.6 3.25 13.8 23000 69.1
PF40281BX-10000-S9H | SUNON 12V 11.4W 40x40x28mm 31.3m3/h 22000rpm DC Axial Fan for New Energy

SUNON PF40281BX-10000-S9H is a 12 VDC DC axial fan in a 40 × 40 × 28 mm format for inverters, energy-storage systems, and charging equipment. 3.12 Pa maximum pressure is the standout documented duty-point value. The recorded airflow profile should guide application screening. Validate approvals and protection at complete-part-number level.

12 40x40x28 31.3 3.12 11.4 22000 62
VF60384BX-10000-A9H | SUNON 48V 22.08W 60x60x38mm 115.2m3/h DC Axial Fan for Data Center Cooling

SUNON VF60384BX-10000-A9H combines a 60 × 60 × 38 mm DC axial fan platform with a 48 VDC rating for servers and data-center electronics. 1205.6 Pa maximum pressure is the standout documented duty-point value. Treat the motor input as a primary input to project documentation. Reconcile the model code with the required electrical interface.

48 60x60x38mm 115.2 1205.6 22.08 22800 64.1
VF60384B1-10000-A9H | SUNON 48V 12.72W 60x60x38mm 91.9m3/h DC Axial Fan for Data Center Cooling

Configured for servers and data-center electronics, SUNON VF60384B1-10000-A9H is a 48 VDC DC axial fan in a 60 × 60 × 38 mm frame. 1053.7 Pa maximum pressure is the standout documented duty-point value. Base project documentation on the stated ventilation capacity. Reconcile the model code with the required electrical interface.

48 60x60x38mm 91.9 1053.7 12.72 18300 60.9
VF60381BX-0000-A9H | SUNON 12V 22.8W 60x60x38mm 115.2m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON VF60381BX-0000-A9H serves as a 60 × 60 × 38 mm DC axial fan operating at 12 VDC. 1205.6 Pa maximum pressure is the standout documented duty-point value. During project documentation, compare the model's equipment fit. Reconcile the model code with the required electrical interface.

12 60x60x38mm 115.2 1205.6 22.8 22800 64.1
显示
61-80
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1011
共 1,011 个
1 2 3 4 5 6 7 8 9 10 ... 50 51
跳转 页

关于DC粉丝

如何选择合适的DC粉丝

确定DC粉丝最可靠的方法是从系统出发,而不是从产品目录出发。先实测或计算风量和压力需求,再加上安装位置的尺寸限制,最后才从曲线能以裕量覆盖您工作点的系列中筛选。

电气匹配是下一道关口。确认供电电压——小型电子散热常用 12 V、24 V 或 48 V DC,设备和机柜散热常用 115 V 或 230 V AC——并确定是否需要调速。EC 风机支持 PWM 或 0-10 V 信号调速,并可通过测速输出反馈转速,是变风量系统的默认之选;AC 风机在定速工况下则依然是高性价比方案。

接下来按环境筛选。高温环境、粉尘或潮湿负载决定了 IP 防护等级和轴承选择——滚珠轴承能让风量和噪音多年保持稳定,含油轴承则适合轻载卧式安装。UL、CE、RoHS 等法规认证要求应在入围名单提交采购前确认,同时确定允许的最大声压级(dBA)。

流程的最后是确认供应而不只是确认参数:确认当前库存和补货交期,取得规格书和尺寸图,确保机械接口在下单前验证完毕。把风量和压力需求发给我们,工程师将为您确认匹配度最高的系列 —— 该分类今天共有 1,011 件产品可供选购。

DC粉丝的典型应用场景与案例

我们销售工程师的日常工作围绕DC粉丝展开:数据中心散热、制冷与冷链项目、建筑通风、通信基站、医疗设备和工业控制柜——在这些环境中,风机停转就意味着业务停摆。正是这种对真实安装场景的日常积累,让我们在每一次选型中不只会看曲线,更清楚哪些型号能经受粉尘、高温、连续运行和维护空间受限的考验。

一个典型案例:某设备制造商需要更换控制柜内一台老旧 AC 风机,且柜体停机时间不能超过一小时。通过逐一核对机壳尺寸、电压和风量曲线,我们提供了带匹配测速信号的在产系列直接替换型号,更换工作在一个计划维护窗口内完成。

制冷与冷链客户带来另一种典型情况:损坏的冷凝器风机数周内无法到货。通过比对直径、转速、轴承和 IP 防护等级,我们从现货提供功能等效的机组,让系统当周恢复运行——这也是众多维修服务公司保存我们联系方式的原因。

从单件紧急替换到面向设备制造商的批量供应,每一单 SUNON 询价我们都遵循同一原则:先核实参数,再报价——确保送到现场的就是项目真正需要的那台风机。

DC粉丝采购常见问题解答

批量采购前可以单件下单或申请样品吗?

欢迎单件订购和样品申请——许多客户都会先在系统中验证一台样机,再决定批量采购。标准现货型号不设最低起订量,且多数复购订单可在批量货款中抵扣样品费。请告诉我们计划使用的数量,我们将同时给出两种方案的报价。

是否支持DC粉丝的定制或 OEM 版本?

可以。除标准目录型号外,我们可以洽谈修改引线、接口、调速曲线、IP 防护升级或 OEM 贴牌包装等方案。定制通常从约定的年用量起步;我们的工程师会先评审您的需求,并在任何承诺之前确认可行性、模具费用和交期。

贵司提供怎样的质保和售后支持?

每台机组均享受制造商针对材料和工艺缺陷的质保,索赔全程由我们协助处理,您只需对接一家供应商,无需跨国追查工厂。如在使用中出现故障,请提供序列号、运行工况和照片,我们将按报价约定的方式安排更换或退款。

袋装

袋装(Bag packaging)是指由制造商将指定数量的产品装入袋、密封袋或类似容器中,作为一个整体出售,无需重新包装。该术语也用于描述套件/组合装,即组件按零件号或参数值分装在独立的袋子中,而不是装入分格盒或类似的刚性容器。